First experimental results of time-of-flight reconstruction on an LSO PET scanner
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Time-of-flight (TOF) positron emission tomography (PET) was studied and preliminarily developed in the 1980s, but the lack of a scintillator able to deliver at the same time proper time resolution and stopping power has prevented this technique from becoming widespread and commercially available. With the introduction of LSO in PET, TOF is now a feasible option. TOF reconstruction has been implemented in the CPS Hi-Rez PET scanner, both with 2D filtered-back-projection (FBP2D) and 3D ordered subset expectation maximization (OSEM3D). A new procedure has been introduced in the time alignment to compensate for the limited digital time resolution of the present electronics. A preliminary version of scatter correction for TOF has been devised and is presented. The measured time resolution of 1.2 ns (FWHM) allowed for a signal-to-noise ratio increase of about 50% in phantoms of about 40 cm transaxial size, or a gain larger than 2 in noise equivalent counts (NEC). TOF reconstruction has shown the expected improvement in SNR, both in simulation and experimental data. First experimental results show two improvements of TOF reconstruction over conventional (non-TOF) reconstruction: a lower noise level and a better capability to resolve structures deep inside large objects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood Reconstruction for Emission Tomography
Shepp, L. A., & Vardi, Y. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307558 · Cited by 4,429
Cerium-doped lutetium oxyorthosilicate: a fast, efficient new scintillator
Melcher, C. L., & Schweitzer, J. S. (1992) · IEEE Transactions on Nuclear Science · doi:10.1109/23.159655 · Cited by 846
Strother, S. C., Casey, M. E., & Hoffman, E. J. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106715 · Cited by 549
Self-citationNew, faster, image-based scatter correction for 3D PET
Watson, C. C. (2000) · IEEE Transactions on Nuclear Science · doi:10.1109/23.873020 · Cited by 519
Time of flight in PET revisited
Moses, W. W. (2003) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2003.817319 · Cited by 336
Time-of-flight positron emission tomography: status relative to conventional PET.
Budinger, T. F. (1983) · PubMed · Cited by 283
Prospects for time-of-flight PET using LSO scintillator
Moses, W. W., & Derenzo, S. E. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775565 · Cited by 240
A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements
Snyder, D. L., Thomas, L. J., & Ter-Pogossian, M. M. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4332168 · Cited by 217 · cited 1×
“The choice of the filter W(ρ) is not unique (Snyder et al 1981, Tomitani 1981, Mallon and Grangeat 1992).”
BackgroundTomitani, T. (1981) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1981.4335769 · Cited by 181
Casey, M. E., & Hoffman, E. J. (1986) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198609000-00027 · Cited by 175
Self-citationCasey, M., & Hoffman, E. J. (1986) · PubMed · Cited by 173
Self-citationLewellen, T. K. (1998) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(98)80031-7 · Cited by 160 · cited 1×
“Recent survey articles on TOF (Lewellen 1998, 0031-9155/05/194507+20$30.00 © 2005 IOP Publishing Ltd Printed in the UK 4507 Moses 2003) show the renewed interest in TOF and connect the past and future of TOF PET research.”
BackgroundInfluentialPolitte, D. G., & Snyder, D. L. (1991) · IEEE Transactions on Medical Imaging · doi:10.1109/42.75614 · Cited by 147
Snyder, D. L., & Politte, D. G. (1983) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1983.4332660 · Cited by 139
POTENTIAL ADVANTAGES OF A CESIUM FLUORIDE SCINTILLATOR FOR A TIME-OF-FLIGHT POSITRON CAMERA
Allemand, R., Gressel, O., Vacher, J., & Sank, V. J. (1980) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198008000-00054 · Cited by 116
Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomograph
Mazoyer, B., Trebossen, R., Schoukroun, C., Verrey, B., Syrota, A., Vacher, J., Lemasson, P., Monnet, O., Bouvier, A., & Lecomte, J. L. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106714 · Cited by 102 · cited 1×
“…positron emission tomography (PET) was studied and preliminarily developed in the 1980s (Allemand et al 1980, Budinger 1983, Laval et al 1983, Lewellen et al 1988, Mazoyer et al 1990, Mullani et al 1980, Snyder and Politte 1983, Tomitani 1981, Yamamoto et al 1989), particularly using CsF or BaF2.”
MethodPerformance measurements of the SP3000/UW time-of-flight positron emission tomograph
Lewellen, T. K., Bice, A. N., Harrison, R. L., Pencke, M. D., & Link, J. M. (1988) · IEEE Transactions on Nuclear Science · doi:10.1109/23.12808 · Cited by 80
Image Reconstruction Algorithms in PET
Defrise, M., Kinahan, P. E., & Michel, C. J. (2005) · Springer eBooks · doi:10.1007/1-84628-007-9_4 · Cited by 74 · cited 2×
“Recent development in TOF FORE (Defrise et al 2005) will allow in the future the implementation of TOF FBP on the whole 3D data set.”
MethodSelf-citationFeasibility of time-of-flight reconstruction in positron emission tomography.
Mullani, N. A., Markham, J., & Ter‐Pogossian, M. M. (1980) · PubMed · Cited by 68
Fast methods for including attenuation in the EM algorithm
Hebert, T. J., & Leahy, R. M. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106710 · Cited by 64
Paans, A. M. J., & van Waarde, A. (2002) · Methods · doi:10.1016/s1046-2023(02)00074-9 · Cited by 39
Politte, D. G. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106707 · Cited by 29
Cited by
PET versus SPECT: strengths, limitations and challenges
Rahmim, A., & Zaidi, H. (2008) · Nuclear Medicine Communications · doi:10.1097/mnm.0b013e3282f3a515 · Cited by 834
Benefit of Time-of-Flight in PET: Experimental and Clinical Results
Karp, J. S., Surti, S., Daube-Witherspoon, M. E., & Muehllehner, G. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044834 · Cited by 584
Parodi, K., Paganetti, H., Shih, H. A., Michaud, S., Loeffler, J. S., DeLaney, T. F., Liebsch, N. J., Munzenrider, J. E., Fischman, A. J., Knopf, A., et al. (2007) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.01.063 · Cited by 409
State of the art in total body PET
Vandenberghe, S., Moskal, P., & Karp, J. S. (2020) · EJNMMI Physics · doi:10.1186/s40658-020-00290-2 · Cited by 390
Focus on time-of-flight PET: the benefits of improved time resolution
Conti, M. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-010-1711-y · Cited by 335
Self-citation
Metadata
- Authors
- Conti, M., Bendriem, B., Casey, M., Chen, M., Kehren, F., Michel, C., & Panin, V.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-09-13
- Volume
- 50
- Issue
- 19
- Pages
- 4507-4526
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2170520519
- Cited by
- 164
- References
- 22
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.