Development of the female voxel phantom, NAOMI, and its application to calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper outlines the development of a 2 mm resolution voxel model, NAOMI (aNAtOMIcal model), designed to be representative of the average adult female. The primary medical imaging data were derived from a high-resolution MRI scan of a 1.65 m tall, 23 year old female subject with a mass of 58 kg. The model was rescaled to a height of 1.63 m and a mass of 60 kg, the dimensions of the International Commission on Radiological Protection reference adult female. There are 41 tissue types in the model. The application of NAOMI to the calculations of induced current densities and electric fields from applied low frequency magnetic and electric fields is described. Comparisons are made with values from the male voxel model, NORMAN. The calculations were extended from 50 Hz up to 10 MHz. External field reference levels are compared with the ICNIRP guidelines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ahlbom, A. (1998) · Health Physics · Cited by 5,817
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/002 · Cited by 4,270
Gabriel, S., Lau, R. W., & Gabriel, C. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/003 · Cited by 4,175 · cited 2×
“An evaluated review of the dielectric properties of all the tissue types in NORMAN was performed by Gabriel et al (1995, 1996a, 1996b, 1996c).”
MethodInfluentialThe dielectric properties of biological tissues: I. Literature survey
Gabriel, C., Gabriel, S., & Corthout, E. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/11/001 · Cited by 3,156
Computational Electromagnetics: The Finite-Difference Time-Domain Method
Taflove, A., Hagness, S. C., & Piket-May, M. (2005) · The Electrical Engineering Handbook · doi:10.1016/b978-012170960-0/50046-3 · Cited by 1,514
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
Basic anatomical and physiological data for use in radiological protection : reference values
Valentin, J. (2002) · Medical Entomology and Zoology · Cited by 680
Herbertz, J. (1998) · PubMed · Cited by 598
Dimbylow, P. J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/3/003 · Cited by 284
Self-citationNumerical dosimetry at power-line frequencies using anatomically based models
Gandhi, O. P., & Chen, J.-Y. (1992) · Bioelectromagnetics · doi:10.1002/bem.2250130706 · Cited by 195
Orcutt, N., & Gandhi, O. P. (1988) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.4590 · Cited by 181
High-resolution organ dosimetry for human exposure to low-frequency magnetic fields
Dawson, T. W., & Stuchly, M. A. (1998) · IEEE Transactions on Magnetics · doi:10.1109/20.668071 · Cited by 140
Impedence Method for Calculation of Power Deposition Patterns in Magnetically Induced Hyperthermia
Gandhi, O. P., Deford, J. F., & Kanai, H. (1984) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1984.325314 · Cited by 136
Fill, U. A., Zankl, M., Petoussi-Henss, N., Siebert, M., & Regulla, D. F. (2004) · Health Physics · doi:10.1097/00004032-200403000-00003 · Cited by 111
Induced electric currents in models of man and rodents from 60 Hz magnetic fields
Xi, W., Stuchly, M. A., & Gandhi, O. P. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.335839 · Cited by 93
Furse, C. M., & Gandhi, O. P. (1998) · Bioelectromagnetics · doi:10.1002/(sici)1521-186x(1998)19:5<293::aid-bem3>3.0.co;2-x · Cited by 89
Parametric dependence of SAR on permittivity values in a man model
Gajšek, P., Hurt, W. D., Ziriax, J. M., & Mason, P. A. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.951520 · Cited by 74
Application of the finite difference time domain algorithm to quasi‐static field analysis
Moerloose, J. D., Dawson, T. W., & Stuchly, M. A. (1997) · Radio Science · doi:10.1029/96rs03690 · Cited by 72
Cited by
GUIDELINES FOR LIMITING EXPOSURE TO TIME-VARYING ELECTRIC AND MAGNETIC FIELDS (1 Hz TO 100 kHz)
(2010) · Health Physics · doi:10.1097/hp.0b013e3181f06c86 · Cited by 2,164
Radiation Dose to Patients From Cardiac Diagnostic Imaging
Einstein, A. J., Moser, K. W., Thompson, R. C., Cerqueira, M. D., & Henzlova, M. J. (2007) · Circulation · doi:10.1161/circulationaha.107.688101 · Cited by 806
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
“…from medical images were first developed in the 1980s (Zubal et al 1994, Jones 1997, Mason et al 2000, Gjonaj et al 2002, Petoussi-Henss et al 2002, Lee et al 2004, Dimbylow 2005, Sato et al 2007, Zhang et al 2007, Sato et al 2009, Christ et al 2010, Xu et al 2000) and are now commonly in use.”
BackgroundMethodXu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
MIDA: A Multimodal Imaging-Based Detailed Anatomical Model of the Human Head and Neck
Iacono, M. I., Neufeld, E., Akinnagbe, E., Bower, K., Wolf, J., Vogiatzis Oikonomidis, I., Sharma, D., Lloyd, B., Wilm, B. J., Wyss, M., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0124126 · Cited by 273
Metadata
- Authors
- Dimbylow, P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2005-02-24
- Volume
- 50
- Issue
- 6
- Pages
- 1047-1070
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1994943748
- Cited by
- 276
- References
- 19
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.