Ultrasound imaging
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Ultrasound imaging is now in very widespread clinical use. The most important underpinning technologies include transducers, beam forming, pulse compression, tissue harmonic imaging, contrast agents, techniques for measuring blood flow and tissue motion, and three-dimensional imaging. Specialized and emerging technologies include tissue characterization and image segmentation, microscanning and intravascular scanning, elasticity imaging, reflex transmission imaging, computed tomography, Doppler tomography, photoacoustics and thermoacoustics. Phantoms and quality assurance are necessary to maintain imaging performance. Contemporary ultrasonic imaging procedures seem to be safe but studies of bioeffects are continuing. It is concluded that advances in ultrasonic imaging have primarily been pushed by the application of physics and innovations in engineering, rather than being pulled by the identification of specific clinical objectives in need of scientific solutions. Moreover, the opportunities for innovation to continue into the future are both challenging and exciting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Advances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
Imaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Mechanisms of contrast agent destruction
Chomas, J. E., Dayton, P., Allen, J., Morgan, K., & Ferrara, K. W. (2001) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.896136 · Cited by 362
A review of calibration techniques for freehand 3-D ultrasound systems
Mercier, L., Langø, T., Lindseth, F., & Collins, D. L. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.11.015 · Cited by 326
Three-dimensional ultrasound imaging
Nelson, T. R., & Pretorius, D. H. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00043-x · Cited by 286
Misaridis, T. X., & Jensen, J. A. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1406546 · Cited by 274
Cross-beam vector Doppler ultrasound for angle-independent velocity measurements
Dunmire, B., Beach, K. W., Labs, K.-H., Plett, M., & Strandness, D. E. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00287-8 · Cited by 272 · cited 1×
“For further information, refer to Bohs et al (1998), Dunmire et al (2000), Fan et al (2001), Jansson et al (2003) and Schlaikjer and Jensen (2004).”
MethodMaximum likelihood segmentation of ultrasound images with Rayleigh distribution
Sarti, A., Corsi, C., Mazzini, E., & Lamberti, C. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1504017 · Cited by 213
Rationale and derivation of MI and TI—a review
Abbott, J. G. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00172-0 · Cited by 202
Spirou, G. M., Oraevsky, A. A., Vitkin, I. A., & Whelan, W. M. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/14/n01 · Cited by 177
Experimental study of high frame rate imaging with limited diffraction beams
Lu, J.-Y. (1998) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.646914 · Cited by 159
Monitoring structural changes in cells with high-frequency ultrasound signal statistics
Tunis, A. S., Czarnota, G. J., Giles, A., Sherar, M. D., HUNT, J. W., & Kolios, M. C. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.04.020 · Cited by 136
Poroelastography: imaging the poroelastic properties of tissues
Konofagou, E. E., Harrigan, T. P., Ophir, J., et al. (2001) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00433-1 · Cited by 135
Fowlkes, J. B., & Holland, C. K. (2000) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2000.19.2.69 · Cited by 133
Kruger, R. A. (1994) · Medical Physics · doi:10.1118/1.597367 · Cited by 130
Tissue-characterization of the prostate using radio frequency ultrasonic signals
Schmitz, G., Ermert, H., & Senge, T. (1999) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.741523 · Cited by 90
Wang, Y., Stephens, D. N., & O’Donnell, M. P. (2002) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2002.1159845 · Cited by 71
A 100-200 MHz ultrasound biomicroscope
Knspik, D. A., Starkoski, B. G., Pavlin, C. J., & Foster, F. S. (2000) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/58.883543 · Cited by 69
Prostate cancer multi-feature analysis using trans-rectal ultrasound images
Mohamed, S., Salama, M. M. A., Kamel, M. S., El-Saadany, E. F., Rizkalla, K. S., & Chin, J. L. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/15/n02 · Cited by 36
Jansson, T. T., Hernandez‐Andrade, E. A., Lingman, G., & Maršál, K. (2003) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(03)01050-0 · Cited by 33
Potential of gold-bound microtubules as a new ultrasound contrast agent
Bekeredjian, R., Behrens, S. S., Ruef, J., Dinjus, E., Unger, E., Baum, M., & Kuecherer, H. F. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(02)00502-1 · Cited by 23
A phantom with reduced complexity for spatial 3-D ultrasound calibration
Dandekar, S., Li, Y., Molloy, J., & Hossack, J. A. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.04.008 · Cited by 21
Hu, Y., Qin, S., & Jiang, Q. Y. (2004) · PubMed · Cited by 11
Hu, Y., Qin, S., & Jiang, Q. Y. (2004) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2004.1320740 · Cited by 10
Coleman, D. P., Rakebrandt, F., Pugh, N., Crawford, D. C., & Woodcock, J. P. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.12.019 · Cited by 7
Cited by
Reactive oxygen species generating systems meeting challenges of photodynamic cancer therapy
Zhou, Z., Song, J., Nie, L., & Chen, X. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00271d · Cited by 2,098
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Self-citationReview of piezoelectric micromachined ultrasonic transducers and their applications
Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa851b · Cited by 340
A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
Rathod, V. T. (2020) · Sensors · doi:10.3390/s20144051 · Cited by 328
Cafarelli, A., Marino, A., Vannozzi, L., Puigmartí-Luis, J., Pané, S., Ciofani, G., & Ricotti, L. (2021) · ACS Nano · doi:10.1021/acsnano.1c03087 · Cited by 327
Metadata
- Authors
- Wells, P. N. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-06-20
- Volume
- 51
- Issue
- 13
- Pages
- R83-R98
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2998457429
- Cited by
- 287
- References
- 27
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.