Ultrasound imaging
The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Ultrasound imaging is now in very widespread clinical use. The most important underpinning technologies include transducers, beam forming, pulse compression, tissue harmonic imaging, contrast agents, techniques for measuring blood flow and tissue motion, and three-dimensional imaging. Specialized and emerging technologies include tissue characterization and image segmentation, microscanning and intravascular scanning, elasticity imaging, reflex transmission imaging, computed tomography, Doppler tomography, photoacoustics and thermoacoustics. Phantoms and quality assurance are necessary to maintain imaging performance. Contemporary ultrasonic imaging procedures seem to be safe but studies of bioeffects are continuing. It is concluded that advances in ultrasonic imaging have primarily been pushed by the application of physics and innovations in engineering, rather than being pulled by the identification of specific clinical objectives in need of scientific solutions. Moreover, the opportunities for innovation to continue into the future are both challenging and exciting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Acoustic radiation force impulse imaging: in vivo demonstration of clinical feasibility
Nightingale, K., Soo, M. S., Nightingale, R., & Trahey, G. (2002) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(01)00499-9 · Cited by 1,108
Three-dimensional ultrasound imaging
Fenster, A., Downey, D. B., & Cardinal, H. N. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/5/201 · Cited by 812
Advances in ultrasound biomicroscopy
Foster, F. S., Pavlin, C. J., Harasiewicz, K. A., Christopher, D. A., & Turnbull, D. H. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(99)00096-4 · Cited by 719
Imaging of the elastic properties of tissue—A review
Gao, L., Parker, K. J., Lerner, R. M., & Levinson, S. F. (1996) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(96)00120-2 · Cited by 514
Mechanisms of contrast agent destruction
Chomas, J. E., Dayton, P., Allen, J., Morgan, K., & Ferrara, K. W. (2001) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.896136 · Cited by 362
A review of calibration techniques for freehand 3-D ultrasound systems
Mercier, L., Langø, T., Lindseth, F., & Collins, D. L. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2004.11.015 · Cited by 326
Three-dimensional ultrasound imaging
Nelson, T. R., & Pretorius, D. H. (1998) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00043-x · Cited by 286
Misaridis, T. X., & Jensen, J. A. (2005) · IEEE Transactions on Ultrasonics Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1406546 · Cited by 274
Cross-beam vector Doppler ultrasound for angle-independent velocity measurements
Dunmire, B., Beach, K. W., Labs, K.-H., Plett, M., & Strandness, D. E. (2000) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(00)00287-8 · Cited by 272 · cited 1×
“For further information, refer to Bohs et al (1998), Dunmire et al (2000), Fan et al (2001), Jansson et al (2003) and Schlaikjer and Jensen (2004).”
MethodMaximum likelihood segmentation of ultrasound images with Rayleigh distribution
Sarti, A., Corsi, C., Mazzini, E., & Lamberti, C. (2005) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/tuffc.2005.1504017 · Cited by 213
Cited by
Reactive oxygen species generating systems meeting challenges of photodynamic cancer therapy
Zhou, Z., Song, J., Nie, L., & Chen, X. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00271d · Cited by 2,098
Medical ultrasound: imaging of soft tissue strain and elasticity
Wells, P. N. T., & Liang, H.-D. (2011) · Journal of The Royal Society Interface · doi:10.1098/rsif.2011.0054 · Cited by 538
Self-citationReview of piezoelectric micromachined ultrasonic transducers and their applications
Jung, J., Lee, W., Kang, W., Shin, E., Ryu, J., & Choi, H. (2017) · Journal of Micromechanics and Microengineering · doi:10.1088/1361-6439/aa851b · Cited by 340
A Review of Acoustic Impedance Matching Techniques for Piezoelectric Sensors and Transducers
Rathod, V. T. (2020) · Sensors · doi:10.3390/s20144051 · Cited by 328
Cafarelli, A., Marino, A., Vannozzi, L., Puigmartí-Luis, J., Pané, S., Ciofani, G., & Ricotti, L. (2021) · ACS Nano · doi:10.1021/acsnano.1c03087 · Cited by 327
Clinical usefulness of variable-frequency ultrasound in localized lesions of the skin
Wortsman, X., & Wortsman, J. (2010) · Journal of the American Academy of Dermatology · doi:10.1016/j.jaad.2009.06.016 · Cited by 302
Roovers, S., Segers, T., Lajoinie, G., Deprez, J., Versluis, M., De Smedt, S. C., & Lentacker, I. (2019) · Langmuir · doi:10.1021/acs.langmuir.8b03779 · Cited by 256
3D bioprinting and its in vivo applications
Hong, N., Yang, G., Lee, J., & Kim, G. (2018) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.33826 · Cited by 243
Daoudi, K., van den Berg, P. J., Rabot, O., Kohl, A., Tisserand, S., Brands, P., & Steenbergen, W. (2014) · Optics Express · doi:10.1364/oe.22.026365 · Cited by 238
Ultrasound image enhancement: A review
Contreras Ortiz, S. H., Chiu, T., & Fox, M. D. (2012) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2012.02.002 · Cited by 230
PBCA-based polymeric microbubbles for molecular imaging and drug delivery
Koczera, P., Appold, L., Shi, Y., Liu, M., Dasgupta, A., Pathak, V., Ojha, T., Fokong, S., Wu, Z., van Zandvoort, M., et al. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.03.006 · Cited by 85
Xu, Y., Tan, W., Chen, M., Chen, S., Tang, K., Liao, H., & Niu, C. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.955127 · Cited by 24
“4T1 cells (1 × 105 cells/well) were seeded in the 6-well plates and treated with different conditions: (Hussain and Nguyen, 2014) PBS, (Wells, 2006) US, (Wu et al., 2005) IR780/PLGA NPs, (Ahmadi et al., 2020) IR780/PLGA NPs + US, (Qian et al., 2016) IR780/PLGA@MnO2 NPs, (Wood and Sehgal, 2015)…”
BackgroundMethodInfluential
Metadata
- Authors
- Wells, P. N. T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-06-20
- Volume
- 51
- Issue
- 13
- Pages
- R83-R98
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2998457429
- Cited by
- 287
- References
- 27
- FWCI
- 6.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.