Improved k–t BLAST and k–t SENSE using FOCUSS
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
The dynamic MR imaging of time-varying objects, such as beating hearts or brain hemodynamics, requires a significant reduction of the data acquisition time without sacrificing spatial resolution. The classical approaches for this goal include parallel imaging, temporal filtering and their combinations. Recently, model-based reconstruction methods called k-t BLAST and k-t SENSE have been proposed which largely overcome the drawbacks of the conventional dynamic imaging methods without a priori knowledge of the spectral support. Another recent approach called k-t SPARSE also does not require exact knowledge of the spectral support. However, unlike k-t BLAST/SENSE, k-t SPARSE employs the so-called compressed sensing (CS) theory rather than using training. The main contribution of this paper is a new theory and algorithm that unifies the above mentioned approaches while overcoming their drawbacks. Specifically, we show that the celebrated k-t BLAST/SENSE are the special cases of our algorithm, which is asymptotically optimal from the CS theory perspective. Experimental results show that the new algorithm can successfully reconstruct a high resolution cardiac sequence and functional MRI data even from severely limited k-t samples, without incurring aliasing artifacts often observed in conventional methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639 · cited 4×
“Perhaps the most important implication of the compressed sensing theory is that the optimal sparse solution satisfying the abovementioned properties can be obtained by solving the L1 minimization [20, 21].”
BackgroundMethodInfluentialStatistical parametric maps in functional imaging: A general linear approach
Friston, K. J., Holmes, A. P., Worsley, K. J., Poline, J. ‐., Frith, C. D., & Frackowiak, R. S. J. (1994) · Human Brain Mapping · doi:10.1002/hbm.460020402 · Cited by 9,688 · cited 1×
“After we obtained the full k-space data, we used the SPM (statistical parametric mapping [32]) toolbox on Matlab to analyze the activated parts during the right finger tapping.”
MethodDecoding by Linear Programming
Candes, E. J., & Tao, T. (2005) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.858979 · Cited by 7,121
Stable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036 · cited 1×
“Here, recent theory of the compressed sensing (CS) [20, 21, 28, 29, 30] can be applied.”
BackgroundSENSE: Sensitivity encoding for fast MRI
Pruessmann, K. P., Weiger, M., Scheidegger, M. B., & Boesiger, P. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199911)42:5<952::aid-mrm16>3.0.co;2-s · Cited by 6,251 · cited 1×
“For example, SMASH (SiMultaneous Acquisition of Spatial Harmonics)[5], SENSE (SENSitivity Encoding) [6], PILS (Partially Parallel Imaging with Localized Sensitivities)[7], and GRAPPA (GeneRalized Autocalibrating Partially Parallel Acquisitions)[8] reduce the scan time by skipping the phase encoding steps.”
MethodGeneralized autocalibrating partially parallel acquisitions (GRAPPA)
Griswold, M. A., Jakob, P. M., Heidemann, R. M., Nittka, M., Jellus, V., Wang, J., Kiefer, B., & Haase, A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10171 · Cited by 5,303 · cited 1×
“For example, SMASH (SiMultaneous Acquisition of Spatial Harmonics)[5], SENSE (SENSitivity Encoding) [6], PILS (Partially Parallel Imaging with Localized Sensitivities)[7], and GRAPPA (GeneRalized Autocalibrating Partially Parallel Acquisitions)[8] reduce the scan time by skipping the phase encoding steps.”
MethodAn Introduction to Signal Detection and Estimation
Poor, H. V. (1988) · Springer Texts in Electrical Engineering · doi:10.1007/978-1-4757-3863-6 · Cited by 3,149
An Introduction to Signal Detection and Estimation
Poor, H. V. (1994) · Springer Texts in Electrical Engineering · doi:10.1007/978-1-4757-2341-0 · Cited by 2,659 · cited 1×
“In Section 4, we will show that the KL transform is very effective for functional MRI analysis.”
Background
Cited by
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
“Dynamic sparsity is beyond our scope; some preliminary results of dynamic CS imaging are reported in (24,25).”
ResultBregman Iterative Algorithms for $\ell_1$-Minimization with Applications to Compressed Sensing
Yin, W., Osher, S., Goldfarb, D., & Darbon, J. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/070703983 · Cited by 1,414
A deep cascade of convolutional neural networks for dynamic MR image reconstruction
Schlemper, J., Caballero, J., Hajnal, J. V., Price, A. N., & Rueckert, D. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2017.2760978 · Cited by 1,338
On instabilities of deep learning in image reconstruction and the potential costs of AI
Antun, V., Renna, F., Poon, C., Adcock, B., & Hansen, A. C. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1907377117 · Cited by 779
k‐t FOCUSS: A general compressed sensing framework for high resolution dynamic MRI
Jung, H., Sung, K., Nayak, K. S., Kim, E. Y., & Ye, J. C. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21757 · Cited by 669
Self-citationCompressed Sensing MRI Reconstruction Using a Generative Adversarial Network With a Cyclic Loss
Quan, T. M., Nguyen-Duc, T., & Jeong, W.-K. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2820120 · Cited by 609
Convolutional Recurrent Neural Networks for Dynamic MR Image Reconstruction
Qin, C., Schlemper, J., Caballero, J., Price, A. N., Hajnal, J. V., & Rueckert, D. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2863670 · Cited by 603
Highly Undersampled Magnetic Resonance Image Reconstruction via Homotopic $\ell_{0}$-Minimization
Trzasko, J., & Manduca, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.927346 · Cited by 490
Deep Residual Learning for Accelerated MRI Using Magnitude and Phase Networks
Lee, D., Yoo, J., Tak, S., & Ye, J. C. (2018) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2018.2821699 · Cited by 340
Self-citationAn efficient algorithm for compressed MR imaging using total variation and wavelets
Ma, S., Yin, W., Zhang, Y., & Chakraborty, A. (2008) · 2008 IEEE Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2008.4587391 · Cited by 334
Compressed-Sensing MRI With Random Encoding
Haldar, J. P., Hernando, D., & Liang, Z.-P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2085084 · Cited by 308
Compressed sensing for body MRI
Feng, L., Benkert, T., Block, K. T., Sodickson, D. K., Otazo, R., & Chandarana, H. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25547 · Cited by 306
Zhao, B., Haldar, J. P., Christodoulou, A. G., & Liang, Z.-P. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2203921 · Cited by 295
Machine learning in cardiovascular magnetic resonance: basic concepts and applications
Leiner, T., Rueckert, D., Suinesiaputra, A., Baeßler, B., Nezafat, R., Išgum, I., & Young, A. A. (2019) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-019-0575-y · Cited by 282
Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L. (2010) · Medical Physics · doi:10.1118/1.3481510 · Cited by 255
Hollingsworth, K. G. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/r297 · Cited by 238
“Examples of algorithms exploiting spatiotemporal sparsity include k–t FOCUSS (Jung et al 2007) and k–t SPARSE SENSE (Otazo et al 2010).”
MethodHighly accelerated real‐time cardiac cine MRI using k–t SPARSE‐SENSE
Feng, L., Srichai, M. B., Lim, R. P., Harrison, A., King, W., Adluru, G., Dibella, E. V. R., Sodickson, D. K., Otazo, R., & Kim, D. (2013) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24440 · Cited by 232
Dictionary Learning and Time Sparsity for Dynamic MR Data Reconstruction
Caballero, J., Price, A. N., Rueckert, D., & Hajnal, J. V. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2301271 · Cited by 226
“The proposed method is compared to k-t FOCUSS [16] as a representative algorithm of the CS dynamic MRI methods using fixed bases sparsifying transforms.”
BackgroundMethodCompressed sensing MRI: a review from signal processing perspective
Ye, J. C. (2019) · BMC Biomedical Engineering · doi:10.1186/s42490-019-0006-z · Cited by 208
“However, there exists two additional novel- ties in the k-t FOCUSS.”
MethodResultInfluentialSelf-citationTime-Dependent Deep Image Prior for Dynamic MRI
Yoo, J., Jin, K. H., Gupta, H., Yerly, J., Stuber, M., & Unser, M. (2021) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2021.3084288 · Cited by 197
MRI temporal acceleration techniques
Tsao, J., & Kozerke, S. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23640 · Cited by 195
“Like most transform techniques, they are in principle compatible with other domains as well. k-t SPARSE is a single-coil technique, while k-t SPARSE-SENSE combines it with parallel imaging, which was found to reduce spatial and temporal blurring (80). k-t FOCUSS (78) determines an initial estimate of the image series…”
MethodInfluentialCompressed sensing for resolution enhancement of hyperpolarized 13C flyback 3D-MRSI
Hu, S., Lustig, M., Chen, A. P., Crane, J., Kerr, A., Kelley, D. A. C., Hurd, R., Kurhanewicz, J., Nelson, S. J., Pauly, J. M., et al. (2008) · Journal of Magnetic Resonance · doi:10.1016/j.jmr.2008.03.003 · Cited by 186
Garg, R., & Khandekar, R. (2009) · Proceedings of the 26th Annual International Conference on Machine Learning · doi:10.1145/1553374.1553417 · Cited by 161
“, 2004), random projections onto convex sets (Candès & Romberg, 2004), homotopy (Donoho & Tsaig, 2006), weighted least squares (Jung et al., 2007), iterative algorithms based on gradient thresholding and other gradient based approaches (Lustig, 2008; Ma et al.”
BackgroundMethodDirect parametric reconstruction from undersampled (k,t)-space data in dynamic contrast enhanced MRI
Dikaios, N., Arridge, S., Hamy, V., Punwani, S., & Atkinson, D. (2014) · Medical Image Analysis · doi:10.1016/j.media.2014.05.001 · Cited by 40
“The parameter settings for kt-FOCUSS (Jung et al., 2007) were 40 inner iterations, 2 outer iterations, weighting matrix power factor 0.5, and initial estimate corresponding to low-frequency values.”
BackgroundMethodInfluential
Metadata
- Authors
- Jung, H., Ye, J. C., & Kim, E. Y.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-05-10
- Volume
- 52
- Issue
- 11
- Pages
- 3201-3226
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2158928439
- Cited by
- 250
- References
- 27
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.