Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models
Open accessThe DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
Anthropomorphic computational phantoms are computer models of the human body for use in the evaluation of dose distributions resulting from either internal or external radiation sources. Currently, two classes of computational phantoms have been developed and widely utilized for organ dose assessment: (1) stylized phantoms and (2) voxel phantoms which describe the human anatomy via mathematical surface equations or 3D voxel matrices, respectively. Although stylized phantoms based on mathematical equations can be very flexible in regard to making changes in organ position and geometrical shape, they are limited in their ability to fully capture the anatomic complexities of human internal anatomy. In turn, voxel phantoms have been developed through image-based segmentation and correspondingly provide much better anatomical realism in comparison to simpler stylized phantoms. However, they themselves are limited in defining organs presented in low contrast within either magnetic resonance or computed tomography images-the two major sources in voxel phantom construction. By definition, voxel phantoms are typically constructed via segmentation of transaxial images, and thus while fine anatomic features are seen in this viewing plane, slice-to-slice discontinuities become apparent in viewing the anatomy of voxel phantoms in the sagittal or coronal planes. This study introduces the concept of a hybrid computational newborn phantom that takes full advantage of the best features of both its stylized and voxel counterparts: flexibility in phantom alterations and anatomic realism. Non-uniform rational B-spline (NURBS) surfaces, a mathematical modeling tool traditionally applied to graphical animation studies, was adopted to replace the limited mathematical surface equations of stylized phantoms. A previously developed whole-body voxel phantom of the newborn female was utilized as a realistic anatomical framework for hybrid phantom construction. The construction of a hybrid phantom is performed in three steps: polygonization of the voxel phantom, organ modeling via NURBS surfaces and phantom voxelization. Two 3D graphic tools, 3D-DOCTOR and Rhinoceros, were utilized to polygonize the newborn voxel phantom and generate NURBS surfaces, while an in-house MATLAB code was used to voxelize the resulting NURBS model into a final computational phantom ready for use in Monte Carlo radiation transport calculations. A total of 126 anatomical organ and tissue models, including 38 skeletal sites and 31 cartilage sites, were described within the hybrid phantom using either NURBS or polygon surfaces. A male hybrid newborn phantom was constructed following the development of the female phantom through the replacement of female-specific organs with male-specific organs. The outer body contour and internal anatomy of the NURBS-based phantoms were adjusted to match anthropometric and reference newborn data reported by the International Commission on Radiological Protection in their Publication 89. The voxelization process was designed to accurately convert NURBS models to a voxel phantom with minimum volumetric change. A sensitivity study was additionally performed to better understand how the meshing tolerance and voxel resolution would affect volumetric changes between the hybrid-NURBS and hybrid-voxel phantoms. The male and female hybrid-NURBS phantoms were constructed in a manner so that all internal organs approached their ICRP reference masses to within 1%, with the exception of the skin (-6.5% relative error) and brain (-15.4% relative error). Both hybrid-voxel phantoms were constructed with an isotropic voxel resolution of 0.663 mm--equivalent to the ICRP 89 reference thickness of the newborn skin (dermis and epidermis). Hybrid-NURBS phantoms used to create their voxel counterpart retain the non-uniform scalability of stylized phantoms, while maintaining the anatomic realism of segmented voxel phantoms with respect to organ shape, depth and inter-organ positioning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774 · cited 1×
“A review of currently available voxel phantoms was reported by Caon (2004) and in more recently published studies (Dimbylow 2005, Kramer et al 2004a, 2003, Lee et al 2006b, 2006c, Nagaoka et al 2004).”
MethodPiegl, L. (1991) · IEEE Computer Graphics and Applications · doi:10.1109/38.67702 · Cited by 746
Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692 · cited 2×
“They include adult male and female phantoms (Kramer et al 1982), a series of pediatric phantoms (Cristy and Eckerman 1987, Han et al 2006), and those of the pregnant adult female at three stages of gestation (Stabin et al 1995).”
BackgroundMethodInfluentialBasic anatomical and physiological data for use in radiological protection : reference values
Valentin, J. (2002) · Medical Entomology and Zoology · Cited by 680
Ws, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
Dimbylow, P. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/002 · Cited by 276 · cited 1×
“A review of currently available voxel phantoms was reported by Caon (2004) and in more recently published studies (Dimbylow 2005, Kramer et al 2004a, 2003, Lee et al 2006b, 2006c, Nagaoka et al 2004).”
MethodHuman Alimentary Tract Model for Radiological Protection
Commission Internationale de Protection contre les Radiations (2006) · Annals of the ICRP · doi:10.1016/j.icrp.2006.03.001 · Cited by 241
Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/301 · Cited by 239 · cited 2×
“A review of currently available voxel phantoms was reported by Caon (2004) and in more recently published studies (Dimbylow 2005, Kramer et al 2004a, 2003, Lee et al 2006b, 2006c, Nagaoka et al 2004).”
MethodVoxel-based computational models of real human anatomy: a review
Caon, M. (2004) · Radiation and Environmental Biophysics · doi:10.1007/s00411-003-0221-8 · Cited by 213 · cited 1×
“A review of currently available voxel phantoms was reported by Caon (2004) and in more recently published studies (Dimbylow 2005, Kramer et al 2004a, 2003, Lee et al 2006b, 2006c, Nagaoka et al 2004).”
MethodStabin, M. G., Watson, E. E., Cristy, M., Ryman, J. C., Eckerman, K. F., Davis, J. L., Marshall, D., & Gehlen, M. K. (1995) · doi:10.2172/91944 · Cited by 194 · cited 1×
“They include adult male and female phantoms (Kramer et al 1982), a series of pediatric phantoms (Cristy and Eckerman 1987, Han et al 2006), and those of the pregnant adult female at three stages of gestation (Stabin et al 1995).”
BackgroundOrgan dose conversion coefficients for external photon irradiation of male and female voxel models
Zankl, M., Fill, U., Petoussi-Henss, N., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/14/301 · Cited by 162 · cited 2×
“The stomach shape, position and size are highly variable among individuals and even in the same individual during different periods prior and after food intake and digestion (Zankl et al 2002).”
BackgroundQuantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy
Tsui, B. M. W., Zhao, X., Gregoriou, G. K., Lalush, D. S., Frey, E. C., Johnston, R. E., & McCartney, W. H. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.340655 · Cited by 147
Kramer, R., Khoury, H. J., Vieira, J. W., Loureiro, E. C. M., Lima, V. J. M., Lima, F. R. A., & Hoff, G. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/001 · Cited by 131 · cited 3×
“A review of currently available voxel phantoms was reported by Caon (2004) and in more recently published studies (Dimbylow 2005, Kramer et al 2004a, 2003, Lee et al 2006b, 2006c, Nagaoka et al 2004).”
BackgroundMethodFill, U. A., Zankl, M., Petoussi-Henss, N., Siebert, M., & Regulla, D. F. (2004) · Health Physics · doi:10.1097/00004032-200403000-00003 · Cited by 111 · cited 1×
“To overcome this problem, Fill et al (2004) imaged a female subject under barium enema double contrast and subsequently reported a standard segmented intestinal model developed from 300 CT image slices.”
MethodSchlattl, H., Zankl, M., & Petoussi-Henss, N. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/8/006 · Cited by 110
Jones, D. G. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032072 · Cited by 105 · cited 1×
“Several investigators have performed comparison studies between stylized and voxel phantoms for both external radiation sources (Jones 1997, Kramer et al 2005, 2004b, Lee et al 2006a, Staton et al 2003, Zankl et al 2002) and internal radiation sources (Chao and Xu 2001, Jones 1998, Petoussi-Henss…”
BackgroundThe application of voxel phantoms to the internal dosimetry of radionuclides
Zankl, M., Petoussi-Henss, N., Fill, U. A., & Regulla, D. F. (2003) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006299 · Cited by 100 · cited 1×
“…et al 2003, Zankl et al 2002) and internal radiation sources (Chao and Xu 2001, Jones 1998, Petoussi-Henss and Zankl 1998, Stabin and Yoriyaz 2002, Zankl et al 2003), and have reported clear differences in dosimetry results directly attributed to differences in body shape as well as organ size,…”
BackgroundZhang, S. (1999) · Springer eBooks · doi:10.1007/978-0-387-21760-4 · Cited by 75
Chao, T., & Xu, X. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/301 · Cited by 74
Kramer, R. A., Vieira, J. W., Khoury, H. J., & Lima, F. R. D. A. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/6/002 · Cited by 57 · cited 3×
“A review of currently available voxel phantoms was reported by Caon (2004) and in more recently published studies (Dimbylow 2005, Kramer et al 2004a, 2003, Lee et al 2006b, 2006c, Nagaoka et al 2004).”
BackgroundMethodJones, D. G. (1998) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032439 · Cited by 55 · cited 1×
“…(Jones 1997, Kramer et al 2005, 2004b, Lee et al 2006a, Staton et al 2003, Zankl et al 2002) and internal radiation sources (Chao and Xu 2001, Jones 1998, Petoussi-Henss and Zankl 1998, Stabin and Yoriyaz 2002, Zankl et al 2003), and have reported clear differences in dosimetry results…”
BackgroundPHOTON SPECIFIC ABSORBED FRACTIONS CALCULATED IN THE TRUNK OF AN ADULT MALE VOXEL-BASED PHANTOM
Stabin, M. G., & Yoriyaz, H. (2002) · Health Physics · doi:10.1097/00004032-200201000-00005 · Cited by 51 · cited 1×
“…Lee et al 2006a, Staton et al 2003, Zankl et al 2002) and internal radiation sources (Chao and Xu 2001, Jones 1998, Petoussi-Henss and Zankl 1998, Stabin and Yoriyaz 2002, Zankl et al 2003), and have reported clear differences in dosimetry results directly attributed to differences in body shape…”
Background
Cited by
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
“Advanced models of the human body are currently represented by polygon meshes (Xu et al 2007, Christ et al 2010) or non-uniform rational B-spline (NURBS) surfaces (Lee et al 2007, 2008, Segars and Tsui 2009).”
Realistic CT simulation using the 4D XCAT phantom
Segars, W. P., Mahesh, M., Beck, T. J., Frey, E. C., & Tsui, B. M. W. (2008) · Medical Physics · doi:10.1118/1.2955743 · Cited by 412
The UF family of reference hybrid phantoms for computational radiation dosimetry
Lee, C., Lodwick, D., Hurtado, J., Pafundi, D., Williams, J. L., & Bolch, W. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/002 · Cited by 345
Self-citationXu, X. G. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/r233 · Cited by 280
Metadata
- Authors
- Lee, C., Lodwick, D., Hasenauer, D., Williams, J. L., Lee, C., & Bolch, W. E.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2007-05-16
- Volume
- 52
- Issue
- 12
- Pages
- 3309-3333
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1978330980
- Cited by
- 184
- References
- 24
- FWCI
- 10.72
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.