Trajectory analysis for magnetic particle imaging
Open accessThe DOI matches its Crossref record.
Abstract
Recently a new imaging technique called magnetic particle imaging was proposed. The method uses the nonlinear response of magnetic nanoparticles when a time varying magnetic field is applied. Spatial encoding is achieved by moving a field-free point through an object of interest while the field strength in the vicinity of the point is high. A resolution in the submillimeter range is provided even for fast data acquisition sequences. In this paper, a simulation study is performed on different trajectories moving the field-free point through the field of view. The purpose is to provide mandatory information for the design of a magnetic particle imaging scanner. Trajectories are compared with respect to density, speed and image quality when applied in data acquisition. Since simulation of the involved physics is a time demanding task, moreover, an efficient implementation is presented utilizing caching techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Progress in the preparation of magnetic nanoparticles for applications in biomedicine
Roca, A. G., Costo, R., Rebolledo, A. F., Veintemillas-Verdaguer, S., Tartaj, P., González-Carreño, T., Morales, M. P., & Serna, C. J. (2009) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/42/22/224002 · Cited by 412
Magnetic Particle Imaging: A Novel in Vivo Imaging Platform for Cancer Detection
Yu, E. Y., Bishop, M., Zheng, B., Ferguson, R. M., Khandhar, A. P., Kemp, S. J., Krishnan, K. M., Goodwill, P. W., & Conolly, S. M. (2017) · Nano Letters · doi:10.1021/acs.nanolett.6b04865 · Cited by 366
Signal encoding in magnetic particle imaging: properties of the system function
Rahmer, J., Weizenecker, J., Gleich, B., & Borgert, J. (2009) · BMC Medical Imaging · doi:10.1186/1471-2342-9-4 · Cited by 345
Self-citationHuman-sized magnetic particle imaging for brain applications
Graeser, M., Thieben, F., Szwargulski, P., Werner, F., Gdaniec, N., Boberg, M., Griese, F., Möddel, M., Ludewig, P., van de Ven, D., et al. (2019) · Nature Communications · doi:10.1038/s41467-019-09704-x · Cited by 334
Self-citationMultidimensional X-Space Magnetic Particle Imaging
Goodwill, P. W., & Conolly, S. M. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2125982 · Cited by 319
Magnetic particle imaging: current developments and future directions
Panagiotopoulos, N., Vogt, F., Barkhausen, J., Buzug, T. M., Duschka, R. L., Lüdtke-Buzug, K., Ahlborg, M., Bringout, G., Debbeler, C., Gräser, M., et al. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s70488 · Cited by 289
“16 Figure 2 depicts four different trajectories.”
Self-citationWeighted iterative reconstruction for magnetic particle imaging
Knopp, T., Rahmer, J., Sattel, T. F., Biederer, S., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/6/003 · Cited by 199
“Although a mathematical model of the system function exists (Weizenecker et al 2007, Knopp et al 2009) and first promising 1D model-based reconstruction results were recently published by Knopp et al (2010), measuring the system function still results in higher accuracy for 2D imaging.”
MethodSelf-citationProjection X-Space Magnetic Particle Imaging
Goodwill, P. W., Konkle, J. J., Zheng, B., Saritas, E. U., & Conolly, S. T. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2185247 · Cited by 185
“The system matrix is comprised of Fourier components of the temporal signal for every possible location of a point source [1], [2], [4], [14]–[17].”
BackgroundMagnetic particle imaging: visualization of instruments for cardiovascular intervention
Haegele, J., Rahmer, J., Gleich, B., Borgert, J., Wojtczyk, H., Panagiotopoulos, N., Buzug, T. M., Barkhausen, J., & Vogt, F. M. (2012) · Radiology · doi:10.1148/radiol.12120424 · Cited by 151
Self-citationFirst in vivo traveling wave magnetic particle imaging of a beating mouse heart
Vogel, P., Rückert, M. A., Klauer, P., Kullmann, W. H., Jakob, P. M., & Behr, V. C. (2016) · Physics in Medicine & Biology · doi:10.1088/0031-9155/61/18/6620 · Cited by 60
Metadata
- Authors
- Knopp, T., Biederer, S., Sattel, T., Weizenecker, J., Gleich, B., Borgert, J., & Buzug, T. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2008-12-19
- Volume
- 54
- Issue
- 2
- Pages
- 385-397
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2031852422
- Cited by
- 171
- References
- 0
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.