Abstract

PURPOSE: To evaluate the feasibility of different approaches of instrument visualization for cardiovascular interventions guided by using magnetic particle imaging (MPI). MATERIALS AND METHODS: Two balloon (percutaneous transluminal angioplasty) catheters were used. The balloon was filled either with diluted superparamagnetic iron oxide (SPIO) ferucarbotran (25 mmol of iron per liter) or with sodium chloride. Both catheters were inserted into a vessel phantom that was filled oppositional to the balloon content with sodium chloride or diluted SPIO (25 mmol of iron per liter). In addition, the administration of a 1.4-mL bolus of pure SPIO (500 mmol of iron per liter) followed by 5 mL of sodium chloride through a SPIO-labeled balloon catheter into the sodium chloride-filled vessel phantom was recorded. Images were recorded by using a preclinical MPI demonstrator. All images were acquired by using a field of view of 3.6 × 3.6 × 2.0 cm. RESULTS: By using MPI, both balloon catheters could be visualized with high temporal (21.54 msec per image) and sufficient spatial (≤ 3 mm) resolution without any motion artifacts. The movement through the field of view, the inflation and deflation of the balloon, and the application of the SPIO bolus were visualized at a rate of 46 three-dimensional data sets per second. CONCLUSION: Visualization of SPIO-labeled instruments for cardiovascular intervention at high temporal resolution as well as monitoring the application of a SPIO-based tracer by using labeled instruments is feasible. Further work is necessary to evaluate different labeling approaches for diagnostic catheters and guidewires and to demonstrate their navigation in the vascular system after administration of contrast material. SUPPLEMENTAL MATERIAL: http://radiology.rsna.org/lookup/suppl/doi:10.1148/radiol.12120424/-/DC1.

Integrity signals

Registry

Crossref · 10.1148/radiol.12120424

Cites

14 of 14 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • MPI can visualize SPION-labeled catheters with good temporal and spatial resolution upon incorporation of ferucarbotran.

    “Furthermore, MPI has been shown to be able to visualize SPION-labeled catheters, providing good temporal (upon balloon filling) and spatial resolution upon the incorporation of ferucarbotran [197].”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Haegele, J., Rahmer, J., Gleich, B., Borgert, J., Wojtczyk, H., Panagiotopoulos, N., Buzug, T. M., Barkhausen, J., & Vogt, F. M.
Affiliations
  • University Hospital Schleswig-Holstein (DE)
  • Philips (Germany) (DE)
  • University of Lübeck (DE)
Venue
Radiology
Published
2012-12
Volume
265
Issue
3
Pages
933-938
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2120361645
Cited by
151
References
14
Citations by year
2026: 9 · 2025: 16 · 2024: 9 · 2023: 5 · 2022: 11 · 2021: 11 · 2020: 13 · 2019: 14 · 2018: 15 · 2017: 13 · 2016: 10 · 2015: 6 · 2014: 8 · 2013: 11
FWCI
4.55
Type
journal article
Language
en
Open access
closed
Locations
  • Radiology (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Characterization and Applications of Magnetic Nanoparticles
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Advanced MRI Techniques and Applications
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
Keywords
magnetic particle imaging, cardiovascular interventions, percutaneous transluminal angioplasty, balloon catheter, superparamagnetic iron oxide nanoparticles, ferucarbotran, vessel phantom, temporal resolution, catheter navigation
MeSH terms
Contrast Media, Dextrans, Feasibility Studies, Humans, Image Enhancement, Magnetic Resonance Imaging, Polyvinyl Chloride, Sodium Chloride, Angioplasty, Balloon, Coronary, Artifacts, Phantoms, Imaging, Imaging, Three-Dimensional, Magnetite Nanoparticles

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review