Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 164

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Why is TOF PET reconstruction a more robust method in the presence of inconsistent data?

Open access
Conti, Maurizio · 2011 · Physics in Medicine and Biology

Abstract

In order to obtain an accurate and quantitative positron emission tomography (PET) image, emission data need to be corrected for random coincidences, photon attenuation and Compton scattering of photons in the tissue, and detector efficiency response or normalization. The accuracy of these corrections strongly affects the quality of the PET image. There is evidence that time-of-flight (TOF) PET reconstruction is less sensitive than non-TOF reconstruction to inconsistencies between emission data and corrections. The purpose of this study is to analyze and discuss such experimental evidence. In this work, inconsistent correction data (inconsistent normalization, absence of scatter correction and mismatched attenuation correction) are introduced in experimental phantom data. Both TOF and non-TOF reconstructed images are analyzed to examine the effect of flawed data. The behavior of TOF reconstruction in respiratory artifacts, a very common example of inconsistency in the data, is studied in patient images. TOF reconstruction is less sensitive to mismatched attenuation correction, erroneous normalization and poorly estimated scatter correction. Such robustness depends strongly on the time resolution of the TOF PET scanner. In particular, the robustness of TOF in the presence of attenuation correction inconsistencies is discussed, using a simulation of a simple model of respiratory artifacts. We expect new generations of PET scanners, with improved time resolution, to be less and less sensitive to poor quality normalization, scatter and attenuation corrections. This not only reduces artifacts in the PET image, but also opens the way to less stringent requirements for the quality of the CT image (reducing either the equipment cost or the dose to the patient), and for the normalization protocols (simplifying or shortening the normalization procedures). Moreover, TOF reconstruction can be beneficial in multimodalities such as PET/MR, where a direct attenuation measurement is not available and attenuation correction can only be approximated.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0031-9155/56/1/010

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 164

Metadata

Authors
Conti, M.
Venue
Physics in Medicine and Biology
Published
2010-11-30
Volume
56
Issue
1
Pages
155-168
ISSN
  • 0031-9155 (ISSN-L)
  • 1361-6560
OpenAlex
W2064404921
Cited by
164
References
1
FWCI
4.10
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? https://app.cochat.ai/papers/10.1088/0031-9155/56/1/010
The paper
Conti, M. (2011). Why is TOF PET reconstruction a more robust method in the presence of inconsistent data? Physics in Medicine and Biology. https://doi.org/10.1088/0031-9155/56/1/010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.