Convex optimization problem prototyping for image reconstruction in computed tomography with the Chambolle–Pock algorithm
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The primal-dual optimization algorithm developed in Chambolle and Pock (CP) (2011 J. Math. Imag. Vis. 40 1-26) is applied to various convex optimization problems of interest in computed tomography (CT) image reconstruction. This algorithm allows for rapid prototyping of optimization problems for the purpose of designing iterative image reconstruction algorithms for CT. The primal-dual algorithm is briefly summarized in this paper, and its potential for prototyping is demonstrated by explicitly deriving CP algorithm instances for many optimization problems relevant to CT. An example application modeling breast CT with low-intensity x-ray illumination is presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Boyd, S., & Vandenberghe, L. (2004) · doi:10.1017/cbo9780511804441 · Cited by 56,601
Rockafellar, R. T. (1970) · Princeton University Press eBooks · doi:10.1515/9781400873173 · Cited by 10,801
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 1×
“So far, mathematical results have been limited to various types of random sampling [37].”
BackgroundA First-Order Primal-Dual Algorithm for Convex Problems with Applications to Imaging
Chambolle, A., & Pock, T. (2011) · Journal of Mathematical Imaging and Vision · doi:10.1007/s10851-010-0251-1 · Cited by 4,336
Beck, A., & Teboulle, M. (2009) · IEEE Transactions on Image Processing · doi:10.1109/tip.2009.2028250 · Cited by 2,004
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Self-citationSparse and Redundant Representations: From Theory to Applications in Signal and Image Processing
Elad, M. (2010) · doi:10.1007/978-1-4419-7011-4 · Cited by 1,897
Fast calculation of the exact radiological path for a three‐dimensional CT array
Siddon, R. L. (1985) · Medical Physics · doi:10.1118/1.595715 · Cited by 1,535
Bregman Iterative Algorithms for $\ell_1$-Minimization with Applications to Compressed Sensing
Yin, W., Osher, S., Goldfarb, D., & Darbon, J. (2008) · SIAM Journal on Imaging Sciences · doi:10.1137/070703983 · Cited by 1,414
Chen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Green, P. J. (1984) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1984.tb01288.x · Cited by 687
Aspects of Total Variation Regularized L1Function Approximation
Chan, T. F., & Esedoglu, S. (2005) · SIAM Journal on Applied Mathematics · doi:10.1137/040604297 · Cited by 651
Templates for convex cone problems with applications to sparse signal recovery
Becker, S. R., Candès, E. J., & Grant, M. C. (2011) · Mathematical Programming Computation · doi:10.1007/s12532-011-0029-5 · Cited by 608
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
Distance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
Diagonal preconditioning for first order primal-dual algorithms in convex optimization
Pock, T., & Chambolle, A. (2011) · 2011 International Conference on Computer Vision · doi:10.1109/iccv.2011.6126441 · Cited by 393
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Self-citationImproved total variation-based CT image reconstruction applied to clinical data
Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/003 · Cited by 306
A Splitting-Based Iterative Algorithm for Accelerated Statistical X-Ray CT Reconstruction
Ramani, S., & Fessler, J. A. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2175233 · Cited by 257
Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L. (2010) · Medical Physics · doi:10.1118/1.3481510 · Cited by 255
Unmatched projector/backprojector pairs in an iterative reconstruction algorithm
Zeng, G. L., & Gullberg, G. T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870265 · Cited by 228
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
A proximal decomposition method for solving convex variational inverse problems
Combettes, P. L., & Pesquet, J.-C. (2008) · Inverse Problems · doi:10.1088/0266-5611/24/6/065014 · Cited by 207
Algorithm-Enabled Low-Dose Micro-CT Imaging
Han, X., Bian, J., Eaker, D. R., Kline, T. L., Sidky, E. Y., Ritman, E. L., & Pan, X. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2089695 · Cited by 145
Self-citationLi, M., Yang, H., & Kudo, H. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/15/303 · Cited by 132
A constrained, total-variation minimization algorithm for low-intensity x-ray CT
Sidky, E. Y., Duchin, Y., Pan, X., & Ullberg, C. K. (2011) · Medical Physics · doi:10.1118/1.3560887 · Cited by 113
Self-citationAn algorithm for total variation regularization in high-dimensional linear problems
Defrise, M., Vanhove, C., & Liu, X. (2011) · Inverse Problems · doi:10.1088/0266-5611/27/6/065002 · Cited by 101
Image reconstruction exploiting object sparsity in boundary-enhanced X-ray phase-contrast tomography
Sidky, E. Y., Anastasio, M. A., & Pan, X. (2010) · Optics Express · doi:10.1364/oe.18.010404 · Cited by 49
Self-citationImage reconstruction from sparse data in synchrotron-radiation-based microtomography
Xia, D., Xiao, X., Bian, J., Han, X., Sidky, E. Y., Carlo, F. D., & Pan, X. (2011) · Review of Scientific Instruments · doi:10.1063/1.3572263 · Cited by 11
Self-citation
Cited by
Fast and flexible X-ray tomography using the ASTRA toolbox
van Aarle, W., Palenstijn, W. J., Cant, J., Janssens, E., Bleichrodt, F., Dabravolski, A., De Beenhouwer, J., Joost Batenburg, K., & Sijbers, J. (2016) · Optics Express · doi:10.1364/oe.24.025129 · Cited by 1,036
The ASTRA Toolbox: A platform for advanced algorithm development in electron tomography
van Aarle, W., Palenstijn, W. J., De Beenhouwer, J., Altantzis, T., Bals, S., Batenburg, K. J., & Sijbers, J. (2015) · Ultramicroscopy · doi:10.1016/j.ultramic.2015.05.002 · Cited by 973
Condat, L. (2013) · Journal of Optimization Theory and Applications · doi:10.1007/s10957-012-0245-9 · Cited by 912
Learned Primal-Dual Reconstruction
Adler, J., & Oktem, O. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2799231 · Cited by 758
Häggström, I., Schmidtlein, C. R., Campanella, G., & Fuchs, T. J. (2019) · Medical Image Analysis · doi:10.1016/j.media.2019.03.013 · Cited by 322
Metadata
- Authors
- Sidky, E. Y., Jørgensen, J. H., & Pan, X.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-04-27
- Volume
- 57
- Issue
- 10
- Pages
- 3065-3091
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2074567512
- Cited by
- 360
- References
- 30
- FWCI
- 12.02
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.