A review of partial volume correction techniques for emission tomography and their applications in neurology, cardiology and oncology
Open accessThe DOI matches its Crossref record; 130 of the 130 references it cites were found in a registry or an index.
Abstract
Accurate quantification in PET and SPECT requires correction for a number of physical factors, such as photon attenuation, Compton scattering and random coincidences (in PET). Another factor affecting quantification is the limited spatial resolution. While considerable effort has gone into development of routine correction techniques for the former factors, less attention has been paid to the latter. Spatial resolution-related effects, referred to as 'partial volume effects' (PVEs), depend not only on the characteristics of the imaging system but also on the object and activity distribution. Spatial and/or temporal variations in PVE can often be confounding factors. Partial volume correction (PVC) could in theory be achieved by some kind of inverse filtering technique, reversing the effect of the system PSF. However, these methods are limited, and usually lead to noise-amplification or image artefacts. Some form of regularization is therefore needed, and this can be achieved using information from co-registered anatomical images, such as CT or MRI. The purpose of this paper is to enhance understanding of PVEs and to review possible approaches for PVC. We also present a review of clinical applications of PVC within the fields of neurology, cardiology and oncology, including specific examples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
New Guidelines to Evaluate the Response to Treatment in Solid Tumors
Therasse, P., Arbuck, S. G., Eisenhauer, E. A., Wanders, J., Kaplan, R. S., Rubinstein, L., Verweij, J., Van Glabbeke, M., van Oosterom, A. T., Christian, M. C., et al. (2000) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/92.3.205 · Cited by 15,660
Fischl, B., Salat, D. H., Busa, E., Albert, M., Dieterich, M., Haselgrove, C., van der Kouwe, A., Killiany, R., Kennedy, D., Klaveness, S., et al. (2002) · Neuron · doi:10.1016/s0896-6273(02)00569-x · Cited by 8,610
Imaging brain amyloid in Alzheimer's disease with Pittsburgh Compound‐B
Klunk, W. E., Engler, H., Nordberg, A., Wang, Y., Blomqvist, G., Holt, D. P., Bergström, M., Savitcheva, I., Huang, G., Estrada, S., et al. (2004) · Annals of Neurology · doi:10.1002/ana.20009 · Cited by 4,496
Automatically Parcellating the Human Cerebral Cortex
Fischl, B. (2004) · Cerebral Cortex · doi:10.1093/cercor/bhg087 · Cited by 4,253
Accelerated image reconstruction using ordered subsets of projection data
Hudson, H. M., & Larkin, R. S. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363108 · Cited by 3,711
Evaluation of 14 nonlinear deformation algorithms applied to human brain MRI registration
Klein, A., Andersson, J., Ardekani, B. A., Ashburner, J., Avants, B., Chiang, M.-C., Christensen, G. E., Collins, D. L., Gee, J., Hellier, P., et al. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.037 · Cited by 2,227
Young, H., Baum, R., Cremerius, U., Herholz, K., Hoekstra, O., Lammertsma, A. A., Pruim, J., & Price, P. (1999) · European Journal of Cancer · doi:10.1016/s0959-8049(99)00229-4 · Cited by 1,720
Partial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549
Self-citationOllinger, J. M., & Fessler, J. A. (1997) · IEEE Signal Processing Magazine · doi:10.1109/79.560323 · Cited by 1,167
Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143
Cited by
Vallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/14/5471 · Cited by 897
Advances in multimodal data fusion in neuroimaging: Overview, challenges, and novel orientation
Zhang, Y.-D., Dong, Z., Wang, S.-H., Yu, X., Yao, X., Zhou, Q., Hu, H., Li, M., Jiménez-Mesa, C., Ramirez, J., et al. (2020) · Information Fusion · doi:10.1016/j.inffus.2020.07.006 · Cited by 453
Ljungberg, M., Celler, A., Konijnenberg, M. W., Eckerman, K. F., Dewaraja, Y. K., & Sjögreen-Gleisner, K. (2016) · Journal of Nuclear Medicine · doi:10.2967/jnumed.115.159012 · Cited by 369
Greve, D. N., Salat, D. H., Bowen, S. L., Izquierdo-Garcia, D., Schultz, A. P., Catana, C., Becker, J. A., Svarer, C., Knudsen, G. M., Sperling, R. A., et al. (2016) · NeuroImage · doi:10.1016/j.neuroimage.2016.02.042 · Cited by 309
Morbelli, S., Esposito, G., Arbizu, J., Barthel, H., Boellaard, R., Bohnen, N. I., Brooks, D. J., Darcourt, J., Dickson, J. C., Douglas, D., et al. (2020) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04817-8 · Cited by 273
Cortical surface-based analysis reduces bias and variance in kinetic modeling of brain PET data
Greve, D. N., Svarer, C., Fisher, P. M., Feng, L., Hansen, A. E., Baare, W., Rosen, B., Fischl, B., & Knudsen, G. M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.12.021 · Cited by 264
“Some researchers ( Erlandsson et al., 2012; Hutton et al, 2013; Thomas et al., 2012) use the recovery coefficient (RC) to measure bias.”
on behalf of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM), Bucerius, J., Hyafil, F., Verberne, H. J., Slart, R. H. J. A., Lindner, O., Sciagra, R., Agostini, D., Übleis, C., Gimelli, A., et al. (2016) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3259-3 · Cited by 257
Mecca, A. P., O'Dell, R. S., Sharp, E. S., Banks, E. R., Bartlett, H. H., Zhao, W., Lipior, S., Diepenbrock, N. G., Chen, M., Naganawa, M., et al. (2022) · Alzheimer's & Dementia · doi:10.1002/alz.12582 · Cited by 186
Assessment of a white matter reference region for 11 C-UCB-J PET quantification
Rossano, S., Toyonaga, T., Finnema, S. J., Naganawa, M., Lu, Y., Nabulsi, N., Ropchan, J., De Bruyn, S., Otoul, C., Stockis, A., et al. (2020) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x19879230 · Cited by 126
“To assess whether this CS region was subject to any partial volume effects, partial volume correction (PVC) was applied to dynamic (11)C-UCB-J PET images using the iterative Yang’s method.(26) This method produces a voxel-based correction by first creating a piece-wise uniform image with regional mean values, which is…”
MethodA bone marrow toxicity model for 223 Ra alpha-emitter radiopharmaceutical therapy
Hobbs, R. F., Song, H., Watchman, C. J., Bolch, W. E., Aksnes, A.-K., Ramdahl, T., Flux, G. D., & Sgouros, G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/10/3207 · Cited by 122
PET quantification: strategies for partial volume correction
Bettinardi, V., Castiglioni, I., De Bernardi, E., & Gilardi, M. C. (2014) · Clinical and Translational Imaging · doi:10.1007/s40336-014-0066-y · Cited by 105
“Many PVE correction techniques have been proposed in the literature, with the aim of improving PET image quality and quantitative accuracy [8–12].”
BackgroundFlortaucipir F 18 quantitation using parametric estimation of reference signal intensity.
Southekal, S., Devous, M. D., Kennedy, I., Navitsky, M., Lu, M., Joshi, A. D., Pontecorvo, M. J., & Mintun, M. A. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.200006 · Cited by 92
“The fraction of counts spilling in to the reference region depends on the degree of tracer binding (cortical SUVr) and the size of the structure with specific uptake (18,19).”
BackgroundSchaefferkoetter, J., Casey, M., Townsend, D., & El Fakhri, G. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/1465 · Cited by 85
Test-retest reproducibility for the tau PET imaging agent flortaucipir F 18.
Devous, M. D., Joshi, A. D., Navitsky, M., Southekal, S., Pontecorvo, M. J., Shen, H., Lu, M., Shankle, W. R., Seibyl, J. P., Marek, K., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.117.200691 · Cited by 79
“This normalization strategy reduces contamination from blurring due to partial-volume effects (28,29), stabilizes SUVRs by maximizing the volume of the reference region, and also addresses concerns that positioning of the cerebellum can be problematic in some PET scanners, particularly noticeable in multisite clinical…”
BackgroundFinnema, S. J., Toyonaga, T., Detyniecki, K., Chen, M., Dias, M., Wang, Q., Lin, S., Naganawa, M., Gallezot, J., Lu, Y., et al. (2020) · Epilepsia · doi:10.1111/epi.16653 · Cited by 78
Synaptic Loss in Frontotemporal Dementia Revealed by [ 11 C ] UCB‐J Positron Emission Tomography
Malpetti, M., Jones, P. S., Cope, T. E., Holland, N., Naessens, M., Rouse, M. A., Rittman, T., Savulich, G., Whiteside, D. J., Street, D., et al. (2023) · Annals of Neurology · doi:10.1002/ana.26543 · Cited by 53
“For each subject, a [(11)C]UCB-J BPND map was determined from dynamic images corrected for partial volume effects at the voxel level using the iterative Yang method.(25) BPND was calculated using a basis function implementation of the simplified reference tissue model, with centrum semiovale as the reference tissue.”
MethodSynaptic density in carriers of C9orf72 mutations: a [11C]UCB‐J PET study
Malpetti, M., Holland, N., Jones, P. S., Ye, R., Cope, T. E., Fryer, T. D., Hong, Y. T., Savulich, G., Rittman, T., Passamonti, L., et al. (2021) · Annals of Clinical and Translational Neurology · doi:10.1002/acn3.51407 · Cited by 44
Livingston, N. R., Calsolaro, V., Hinz, R., Nowell, J., Raza, S., Gentleman, S., Tyacke, R. J., Myers, J., Venkataraman, A. V., Perneczky, R., et al. (2022) · Molecular Psychiatry · doi:10.1038/s41380-021-01429-y · Cited by 44
“Partial Volume Correction (PVC) was not performed as PVC can increase noise within the data [28], leading to further signal leakage between regions and tissue classes which cannot be corrected for [29].”
BackgroundVisser, M., O’Brien, J. T., & Mak, E. (2024) · Ageing Research Reviews · doi:10.1016/j.arr.2024.102197 · Cited by 28
“To disentangle atrophy from SV2A loss, various PVC methods have been developed (for a review, see Erlandsson et al., 2012).”
MethodStrobel, J., Müller, H.-P., Ludolph, A. C., Beer, A. J., Sollmann, N., & Kassubek, J. (2023) · Cells · doi:10.3390/cells12242776 · Cited by 10
“For example, image resolution can be limited, particularly for small structures such as the hippocampus [145].”
Background
Metadata
- Authors
- Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-10-16
- Volume
- 57
- Issue
- 21
- Pages
- R119-R159
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1975127965
- Cited by
- 733
- References
- 130
- FWCI
- 73.87
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.