X-ray phase-contrast imaging: from pre-clinical applications towards clinics
The DOI matches its Crossref record; 75 of the 75 references it cites were found in a registry or an index.
Abstract
Phase-contrast x-ray imaging (PCI) is an innovative method that is sensitive to the refraction of the x-rays in matter. PCI is particularly adapted to visualize weakly absorbing details like those often encountered in biology and medicine. In past years, PCI has become one of the most used imaging methods in laboratory and preclinical studies: its unique characteristics allow high contrast 3D visualization of thick and complex samples even at high spatial resolution. Applications have covered a wide range of pathologies and organs, and are more and more often performed in vivo. Several techniques are now available to exploit and visualize the phase-contrast: propagation- and analyzer-based, crystal and grating interferometry and non-interferometric methods like the coded aperture. In this review, covering the last five years, we will give an overview of the main theoretical and experimental developments and of the important steps performed towards the clinical implementation of PCI.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hart, M., & Deutsch, M. (1983) · Physics Bulletin · doi:10.1088/0031-9112/34/7/032 · Cited by 4,568
Fourier-transform method of fringe-pattern analysis for computer-based topography and interferometry
Takeda, M., Ina, H., & Kobayashi, S. (1982) · Journal of the Optical Society of America · doi:10.1364/josa.72.000156 · Cited by 4,277
(2016) · Encyclopedia of Nanotechnology · doi:10.1007/978-94-017-9780-1_101037 · Cited by 3,780
Structure Analysis by Small-Angle X-Ray and Neutron Scattering
Feigin, L. A., & Svergun, D. I. (1987) · Springer eBooks · doi:10.1007/978-1-4757-6624-0 · Cited by 2,473
The optical principles of the diffraction of x-rays.
James, R. W. (1954) · CERN Document Server (European Organization for Nuclear Research) · Cited by 2,126
Simultaneous phase and amplitude extraction from a single defocused image of a homogeneous object
Paganin, D., Mayo, S. C., Gureyev, T. E., Miller, P. R., & Wilkins, S. W. (2002) · Journal of Microscopy · doi:10.1046/j.1365-2818.2002.01010.x · Cited by 2,062
Phase retrieval and differential phase-contrast imaging with low-brilliance X-ray sources
Pfeiffer, F., Weitkamp, T., Bunk, O., & David, C. (2006) · Nature Physics · doi:10.1038/nphys265 · Cited by 1,855
Phase-contrast imaging using polychromatic hard X-rays
Wilkins, S. W., Gureyev, T. E., Gao, D., Pogany, A., & Stevenson, A. W. (1996) · Nature · doi:10.1038/384335a0 · Cited by 1,766
Die Röntgenkleinwinkelstreuung von dichtgepackten kolloiden Systemen: I. Teil
Porod, G. (1951) · Kolloid-Zeitschrift · doi:10.1007/bf01512792 · Cited by 1,711
Snigirev, A., Snigireva, I., Kohn, V., Kuznetsov, S., & Schelokov, I. (1995) · Review of Scientific Instruments · doi:10.1063/1.1146073 · Cited by 1,493
Cited by
Withers, P. J., Bouman, C., Carmignato, S., Cnudde, V., Grimaldi, D., Hagen, C. K., Maire, E., Manley, M., Du Plessis, A., & Stock, S. R. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00015-4 · Cited by 1,079
Hot‐Pressed CsPbBr3 Quasi‐Monocrystalline Film for Sensitive Direct X‐ray Detection
Pan, W., Yang, B., Niu, G., Xue, K., Du, X., Yin, L., Zhang, M., Wu, H., Miao, X., & Tang, J. (2019) · Advanced Materials · doi:10.1002/adma.201904405 · Cited by 346
Liu, Y., Ma, J., Fan, Y., & Liang, Z. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/23/7923 · Cited by 335
A flexible and wearable terahertz scanner
Suzuki, D., Oda, S., & Kawano, Y. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.209 · Cited by 244
Dose in x-ray computed tomography
Kalender, W. A. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/3/r129 · Cited by 235
Micro-CT of rodents: State-of-the-art and future perspectives
Clark, D. P., & Badea, C. T. (2014) · Physica Medica · doi:10.1016/j.ejmp.2014.05.011 · Cited by 229
“tissues without the need for exogenous contrast agents and with potentially reduced radiation dose [59,173].”
BackgroundImproving abdomen tumor low-dose CT images using a fast dictionary learning based processing
Chen, Y., Yin, X., Shi, L., Shu, H., Luo, L., Coatrieux, J.-L., & Toumoulin, C. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/16/5803 · Cited by 223
Modelling the physics in the iterative reconstruction for transmission computed tomography
Nuyts, J., De Man, B., Fessler, J. A., Zbijewski, W., & Beekman, F. J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/r63 · Cited by 199
Generating patient specific pseudo-CT of the head from MR using atlas-based regression
Sjölund, J., Forsberg, D., Andersson, M., & Knutsson, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/2/825 · Cited by 161
Otake, Y., Schafer, S., Stayman, J. W., Zbijewski, W., Kleinszig, G., Graumann, R., Khanna, A. J., & Siewerdsen, J. H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5485 · Cited by 79
Advantages of phase retrieval for fast x-ray tomographic microscopy
Mokso, R., Marone, F., Irvine, S., Nyvlt, M., Schwyn, D., Mader, K., Taylor, G. K., Krapp, H. G., Skeren, M., & Stampanoni, M. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/49/494004 · Cited by 56
3D-2D Registration for Surgical Guidance: Effect of Projection View Angles on Registration Accuracy
Uneri, A., Otake, Y., Wang, A. S., Kleinszig, G., Vogt, S., Khanna, A. J., & Siewerdsen, J. H. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/2/271 · Cited by 53
3D–2D registration in mobile radiographs: algorithm development and preliminary clinical evaluation
Otake, Y., Wang, A. S., Uneri, A., Kleinszig, G., Vogt, S., Aygun, N., Lo, S.-F. L., Wolinsky, J.-P., Gokaslan, Z. L., & Siewerdsen, J. H. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/5/2075 · Cited by 41
Parodi, B., Sanna, A., Cedola, A., Uccelli, A., & Kerlero de Rosbo, N. (2021) · Frontiers in Immunology · doi:10.3389/fimmu.2021.655212 · Cited by 20
Metadata
- Authors
- Bravin, A., Coan, P., & Suortti, P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2012-12-10
- Volume
- 58
- Issue
- 1
- Pages
- R1-R35
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2105286970
- Cited by
- 846
- References
- 75
- FWCI
- 97.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.