The DOI matches its Crossref record; 72 of the 74 references it cites were found in a registry or an index.
Optical properties of biological tissues: a review
Open accessAbstract
A review of reported tissue optical properties summarizes the wavelength-dependent behavior of scattering and absorption. Formulae are presented for generating the optical properties of a generic tissue with variable amounts of absorbing chromophores (blood, water, melanin, fat, yellow pigments) and a variable balance between small-scale scatterers and large-scale scatterers in the ultrastructures of cells and tissues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“For the scattering, the average number density (a) is 8.54 ± 1.4 and the average effective particle size (b) is 0.75 ± 0.24, for the relationship derived from the Mie model (Jacques 2013).”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Jacques 2013
Experimental — accuracy not yet measuredIn the citing paper
“In particular, obesity can lead to changes in skin thickness, blood flow, and oxygen saturation. This affects the optical properties of skin in addition to the distance light has to travel to reach a target vessel or vessels [48,59,60].”
From Sources of inaccuracy in photoplethysmography for continuous cardiovascular monitoring (2021) · cites this paper as [48]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of Water in the 200-nm to 200-μm Wavelength Region
Hale, G. M., & Querry, M. R. (1973) · Applied Optics · doi:10.1364/ao.12.000555 · Cited by 4,479
Optical-Thermal Response of Laser-Irradiated Tissue
Welch, A. J., & van Gemert, M. J. C. (2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,455
PhotochemCAD††: A Computer-Aided Design and Research Tool in Photochemistry
Du, H., Fuh, R.-C. A., Li, J., Corkan, L. A., & Lindsey, J. S. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02480.x · Cited by 897
OPTICAL PROPERTIES OF SKIN, SUBCUTANEOUS, AND MUSCLE TISSUES: A REVIEW
Bashkatov, A. N., Genina, E. A., & Tuchin, V. V. (2011) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545811001319 · Cited by 765
Optical-Thermal Response of Laser-Irradiated Tissue
Welch, A. J., & van Gemert, M. J. C. (1995) · Springer eBooks · doi:10.1007/978-1-4757-6092-7 · Cited by 705
Simpson, C. R., Kohl, M., Essenpreis, M., & Cope, M. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/9/003 · Cited by 651
Salomatina, E. V., Jiang, B., Novak, J., & Yaroslavsky, A. N. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2398928 · Cited by 599
The complex refractive index of water
Segelstein, D. J. (1981) · MOspace Institutional Repository (University of Missouri) · Cited by 547
Beekvelt, M. C. P. V., Colier, W. N. J. M., Wevers, R. A., & van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 526
Spectroscopic optical coherence tomography
Morgner, U., Drexler, W., Käertner, F. X., Li, X. D., Pitris, C., Ippen, E. P., & Fujimoto, J. G. (2000) · Optics Letters · doi:10.1364/ol.25.000111 · Cited by 518
Alexandrakis, G., Rannou, F. R., & Chatziioannou, A. F. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/17/021 · Cited by 466
In vivo local determination of tissue optical properties: applications to human brain
Bevilacqua, F. P., Piguet, D., Marquet, P. P., Gross, J. D., Tromberg, B. J., & Depeursinge, C. D. (1999) · Applied Optics · doi:10.1364/ao.38.004939 · Cited by 457
Optical properties of normal and diseased human breast tissues in the visible and near infrared
Peters, V. G., Wyman, D. R., Patterson, M. S., & Frank, G. L. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/9/010 · Cited by 416
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Tutorial on diffuse light transport
Jacques, S. L., & Pogue, B. W. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2967535 · Cited by 354
Turbulent nature of refractive-index variations in biological tissue
Schmitt, J. M., & Kumar, G. (1996) · Optics Letters · doi:10.1364/ol.21.001310 · Cited by 343
Light distributions in artery tissue: Monte Carlo simulations for finite‐diameter laser beams
Keijzer, M., Jacques, S. L., Prahl, S. A., & Welch, A. J. (1989) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900090210 · Cited by 312
Profio, A. E. (1989) · Applied Optics · doi:10.1364/ao.28.002216 · Cited by 307
Measurement of the optical properties of the skull in the wavelength range 650-950 nm
Firbank, M., Hiraoka, M., Essenpreis, M., & Delpy, D. T. (1993) · Physics in Medicine and Biology · doi:10.1088/0031-9155/38/4/002 · Cited by 306
Mie and Rayleigh modeling of visible-light scattering in neonatal skin
Saidi, I. S., Jacques, S. L., & Tittel, F. K. (1995) · Applied Optics · doi:10.1364/ao.34.007410 · Cited by 295
Sources of Absorption and Scattering Contrast for Near-Infrared Optical Mammography
Cerussi, A. E., Berger, A. J., Bevilacqua, F. P., Shah, N. S., Jakubowski, D. B., Butler, J., Holcombe, R. F., & Tromberg, B. J. (2001) · Academic Radiology · doi:10.1016/s1076-6332(03)80529-9 · Cited by 295
Bulk optical properties of healthy female breast tissue
Durduran, T., Choe, R., Culver, J. P., Zubkov, L. A., Holboke, M. J., Giammarco, J. M., Chance, B., & Yodh, A. G. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/16/302 · Cited by 291
Bevilacqua, F. P., Berger, A. J., Cerussi, A. E., Jakubowski, D. B., & Tromberg, B. J. (2000) · Applied Optics · doi:10.1364/ao.39.006498 · Cited by 284
Jacques, S. L., & McAuliffe, D. J. (1991) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1991.tb09891.x · Cited by 278
van Veen, R. L. P., Sterenborg, H. J. C. M., Pifferi, A., Torricelli, A. M., Chikoidze, E., & Cubeddu, R. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2085149 · Cited by 277
Diffuse optical imaging using spatially and temporally modulated light
O’Sullivan, T. D., Cerussi, A. E., Tromberg, B. J., & Cuccia, D. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071311 · Cited by 270
Tromberg, B. J., Coquoz, O., Fishkin, J. B., Pham, T. H., Anderson, E. R., Butler, J., Cahn, M., Gross, J. D., Venugopalan, V., & Pham, D. (1997) · Philosophical Transactions of the Royal Society B Biological Sciences · doi:10.1098/rstb.1997.0047 · Cited by 267
Modeling optical and thermal distributions in tissue during laser irradiation
Jacques, S. L., & Prahl, S. A. (1987) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900060604 · Cited by 259
Zonios, G. I., Dimou, A. D., Bassukas, I. D., Galaris, D., Tsolakidis, A., & Kaxiras, E. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2844710 · Cited by 252
Theoretical Analysis of Diffuse Reflectance from a Two-Layer Tissue Model
Takatani, S., & Graham, M. D. (1979) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1979.326455 · Cited by 249
Origins of Tissue Optical Properties in the UVA, Visible, and NIR Regions
Jacques, S. L. (1996) · Advances in Optical Imaging and Photon Migration · doi:10.1364/aoipm.1996.opc364 · Cited by 247
Selective photothermolysis of lipid-rich tissues: A free electron laser study
Anderson, R. R., Farinelli, W. A., Laubach, H., Manstein, D., Yaroslavsky, A. N., Gubeli, J., Jordan, K., Neil, G. R., Shinn, M. D., Chandler, W., et al. (2006) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20393 · Cited by 245
Matcher, S. J., Cope, M., & Delpy, D. T. (1997) · Applied Optics · doi:10.1364/ao.36.000386 · Cited by 221
Nordlund, J. J. (1985) · The Journal of Dermatology · doi:10.1111/j.1346-8138.1985.tb01547.x · Cited by 208
Jakubowski, D. B., Cerussi, A. E., Bevilacqua, F. P., Shah, N. S., Hsiang, D. J. B., Butler, J., & Tromberg, B. J. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1629681 · Cited by 206
Photodynamic therapy induced vascular damage: an overview of experimental PDT
Wang, W., Moriyama, L. T., & Bagnato, V. S. (2012) · Laser Physics Letters · doi:10.1088/1612-2011/10/2/023001 · Cited by 187
Optical properties of rat liver between 350 and 2200 nm
Parsa, P. S., Jacques, S. L., & Nishioka, N. S. (1989) · Applied Optics · doi:10.1364/ao.28.002325 · Cited by 176
Mourant, J. R., Johnson, T. M., Carpenter, S. G., Guerra, A., Aida, T., & Freyer, J. P. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483317 · Cited by 164
van Veen, R. L. P., Sterenborg, H. J. C. M., Pifferi, A., Torricelli, A. M., & Cubeddu, R. (2004) · Biomedical Topical Meeting · doi:10.1364/bio.2004.sf4 · Cited by 159
Beauvoit, B. P., Evans, S. M., Jenkins, T. W., Miller, E. E., & Chance, B. (1995) · Analytical Biochemistry · doi:10.1006/abio.1995.1205 · Cited by 150
Fractal mechanisms of light scattering in biological tissue and cells
Xu, M. Q., & Alfano, R. R. (2005) · Optics Letters · doi:10.1364/ol.30.003051 · Cited by 147
Spinelli, L., Torricelli, A., Pifferi, A., Taroni, P., Danesini, G. M., & Cubeddu, R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1803546 · Cited by 140
Ijichi, S., Kusaka, T., Isobe, K., Okubo, K., Kawada, K., Namba, M., Okada, H., Nishida, T., Imai, T., & Itoh, S. (2005) · Pediatric Research · doi:10.1203/01.pdr.0000175638.98041.0e · Cited by 137
Svensson, T., Andersson‐Engels, S., Einarsdottir, M., & Svanberg, K. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2435175 · Cited by 131
The Physical Properties of Melanins
Sarna, T., & Swartz, H. A. (2006) · doi:10.1002/9780470987100.ch16 · Cited by 129
Yi, J., & Backman, V. (2012) · Optics Letters · doi:10.1364/ol.37.004443 · Cited by 106
Nonscalar elastic light scattering from continuous random media in the Born approximation
Rogers, J. D., Capoglu, I., & Backman, V. (2009) · Optics Letters · doi:10.1364/ol.34.001891 · Cited by 102
Index-of-refraction-dependent subcellular light scattering observed with organelle-specific dyes
Wilson, J. D., Cottrell, W. J., & Foster, T. H. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2437765 · Cited by 97
Abookasis, D., Lay, C. C., Mathews, M. S., Linskey, M. E., Frostig, R. D., & Tromberg, B. J. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3116709 · Cited by 95
Todd, M. M., Weeks, J. B., & Warner, D. S. (1992) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1992.263.1.h75 · Cited by 77
Ding, H. S., Hou, X., Hou, X. L., & Chance, B. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1891345 · Cited by 71
Bulk optical parameters of porcine skin dermis at eight wavelengths from 325 to 1557 nm
Ma, X., Lu, J. Q., Ding, H., & Hu, X. (2005) · Optics Letters · doi:10.1364/ol.30.000412 · Cited by 69
Dispersion and Absorption of Liquid Water in the Infrared and Radio Regions of the Spectrum
Золотарев, В. М., Mikhailov, B. A., Al'perovich, L. I., & Попов, С. И. (1969) · OptSp · Cited by 69
Erbium laser ablation: The effect of dynamic optical properties
Cummings, J. P., & Walsh, J. T. (1993) · Applied Physics Letters · doi:10.1063/1.109512 · Cited by 67
Solonenko, M. G., Cheung, R. M., Busch, T. M., Kachur, A., Griffin, G. M., Vulcan, T., Zhu, T. C., Wang, H. W., Hahn, S. M., & Yodh, A. G. (2002) · PubMed · Cited by 63
Tseng, T., Chen, C., Li, Y., & Sung, K. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000901 · Cited by 60
Measurement of Ex Vivo and In Vivo Tissue Optical Properties: Methods and Theories
Kim, A., & Wilson, B. C. (2010) · Springer eBooks · doi:10.1007/978-90-481-8831-4_8 · Cited by 57
Xu, M. Q., Wu, T., & Qu, J. Y. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2907790 · Cited by 57
Samatham, R. V., Jacques, S. L., & Campagnola, P. J. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2953195 · Cited by 49
Hall, G., Jacques, S. L., Eliceiri, K. W., & Campagnola, P. J. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002707 · Cited by 49
The optical properties of lung as a function of respiration
Beek, J. F., van Staveren, H. J., Posthumus, P., Sterenborg, H. J. C. M., & van Gemert, M. J. C. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/11/018 · Cited by 35
Regional blood flow, microvascular blood content and tissue haematocrit in canine myocardium
Eliasen, P., Amtorp, O., Tøndevold, E., & Haunsø, S. (1982) · Cardiovascular Research · doi:10.1093/cvr/16.10.593 · Cited by 33
Fujimori, K., Komiyama, T., Tabata, H., Nojima, T., Ishiguro, K., Sawaki, Y., Tatsuzawa, H., & Nakano, M. (1998) · Photochemistry and Photobiology · doi:10.1111/j.1751-1097.1998.tb02481.x · Cited by 28
(2011) · The Internet Journal of Radiology · doi:10.5580/1483 · Cited by 27
Chung, S. H., Yu, H., Su, M., Cerussi, A. E., & Tromberg, B. J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.071304 · Cited by 21
Measuring tissue optical properties in vivo using reflectance-mode confocal microscopy and OCT
Jacques, S. L., Samatham, R. V., Choudhury, N., Fu, Y., & Levitz, D. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.761803 · Cited by 19
Overview of Optical and Thermal Laser-Tissue Interaction and Nomenclature
Welch, A. J., & van Gemert, M. J. C. (2010) · Springer eBooks · doi:10.1007/978-90-481-8831-4_1 · Cited by 18
Tissue blood content in anaesthetised sheep and horses
Weaver, B. M. Q., Staddon, G. E., & Pearson, M. R. B. (1989) · Comparative Biochemistry and Physiology Part A Physiology · doi:10.1016/0300-9629(89)90113-8 · Cited by 13
In Vivo confocal microscopy in turbid media
Gareau, D. S. (2006) · doi:10.6083/m4ng4nj3 · Cited by 8
Linking visual appearance of skin to the underlying optical properties using multispectral imaging
Choudhury, N., Samatham, R. V., & Jacques, S. L. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.842648 · Cited by 8
Determination of optical scattering properties of tissues using reflectance-mode confocal microscopy
Venkata, R. S. (2012) · Cited by 5
Proceedings of, S. P. I. E. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.861225 · Cited by 1
Research works printed but not linked: 11
- Anderson R R, 1982, chapter 6, pp 147–94
- Biswas T K, 2011, Internet. J. Radiol., 13, No 1
- Du H, 1998, Photochem. Photobiol., 68, 141
- Jacques S L, 1987, Lasers Life Sci., 1, 309
- Kim A, 2011, Optical-Thermal Response of Laser-Irradiated Tissue
- Ma X, 2005, Opt. Lett., 30
- Newman C, 1991, Lasers Surg. Med., 75
- Prahl S A, 1988, PhD Dissertation
- Solonenko M, 2002, Phys. Med. Biol., 47, 857
- van Veen R L P Sterenborg H J C M Pifferi A Torricelli A Cubeddu R, 2004, OSA Annual BIOMED Topical Meeting
- Zolotarev V M, 1969, Opt. Spectrosc., 27, 430
Cited by
Sorted by citations
Reactive oxygen species generating systems meeting challenges of photodynamic cancer therapy
Zhou, Z., Song, J., Nie, L., & Chen, X. S. (2016) · Chemical Society Reviews · doi:10.1039/c6cs00271d · Cited by 2,121
Ash, C., Dubec, M., Donne, K., & Bashford, T. (2017) · Lasers in Medical Science · doi:10.1007/s10103-017-2317-4 · Cited by 1,040
Light in diagnosis, therapy and surgery
Yun, S. H., & Kwok, S. J. J. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0008 · Cited by 835
Lifetime-engineered NIR-II nanoparticles unlock multiplexed in vivo imaging
Fan, Y., Wang, P., Lu, Y., Wang, R., Zhou, L., Zheng, X., Li, X., Piper, J. A., & Zhang, F. (2018) · Nature Nanotechnology · doi:10.1038/s41565-018-0221-0 · Cited by 802
Hemmer, E., Benayas, A., Légaré, F., & Vetrone, F. (2016) · Nanoscale Horizons · doi:10.1039/c5nh00073d · Cited by 732
Metadata
- Authors
- Jacques, S. L.
- Affiliations
- Oregon Health & Science University (US)
- Corresponding author
- Jacques, Steven L
- ORCID
- Jacques, Steven L
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-05-10
- Volume
- 58
- Issue
- 11
- Pages
- R37-R61
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2097683070
- Cited by
- 4,008
- References
- 74
- Citations by year
- 2026: 350 · 2025: 346 · 2024: 313 · 2023: 332 · 2022: 323 · 2021: 362 · 2020: 363 · 2019: 383 · 2018: 320 · 2017: 299 · 2016: 272 · 2015: 217 · 2014: 107 · 2013: 15
- FWCI
- 28.94
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Physical Sciences › Engineering › Biomedical Engineering › Optical Coherence Tomography Applications
- Keywords
- tissue optical properties, light scattering, optical absorption, chromophores, blood, melanin, fats, wavelength dependence, cell ultrastructure
- MeSH terms
- Animals, Biology, Humans, Anisotropy, Optical Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review