Dynamic whole-body PET parametric imaging: I. Concept, acquisition protocol optimization and clinical application
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
Static whole-body PET/CT, employing the standardized uptake value (SUV), is considered the standard clinical approach to diagnosis and treatment response monitoring for a wide range of oncologic malignancies. Alternative PET protocols involving dynamic acquisition of temporal images have been implemented in the research setting, allowing quantification of tracer dynamics, an important capability for tumor characterization and treatment response monitoring. Nonetheless, dynamic protocols have been confined to single-bed-coverage limiting the axial field-of-view to ~15-20 cm, and have not been translated to the routine clinical context of whole-body PET imaging for the inspection of disseminated disease. Here, we pursue a transition to dynamic whole-body PET parametric imaging, by presenting, within a unified framework, clinically feasible multi-bed dynamic PET acquisition protocols and parametric imaging methods. We investigate solutions to address the challenges of: (i) long acquisitions, (ii) small number of dynamic frames per bed, and (iii) non-invasive quantification of kinetics in the plasma. In the present study, a novel dynamic (4D) whole-body PET acquisition protocol of ~45 min total length is presented, composed of (i) an initial 6 min dynamic PET scan (24 frames) over the heart, followed by (ii) a sequence of multi-pass multi-bed PET scans (six passes × seven bed positions, each scanned for 45 s). Standard Patlak linear graphical analysis modeling was employed, coupled with image-derived plasma input function measurements. Ordinary least squares Patlak estimation was used as the baseline regression method to quantify the physiological parameters of tracer uptake rate Ki and total blood distribution volume V on an individual voxel basis. Extensive Monte Carlo simulation studies, using a wide set of published kinetic FDG parameters and GATE and XCAT platforms, were conducted to optimize the acquisition protocol from a range of ten different clinically acceptable sampling schedules examined. The framework was also applied to six FDG PET patient studies, demonstrating clinical feasibility. Both simulated and clinical results indicated enhanced contrast-to-noise ratios (CNRs) for Ki images in tumor regions with notable background FDG concentration, such as the liver, where SUV performed relatively poorly. Overall, the proposed framework enables enhanced quantification of physiological parameters across the whole body. In addition, the total acquisition length can be reduced from 45 to ~35 min and still achieve improved or equivalent CNR compared to SUV, provided the true Ki contrast is sufficiently high. In the follow-up companion paper, a set of advanced linear regression schemes is presented to particularly address the presence of noise, and attempt to achieve a better trade-off between the mean-squared error and the CNR metrics, resulting in enhanced task-based imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1994) · doi:10.1201/9780429246593 · Cited by 40,500
An Introduction to the Bootstrap
Efron, B., & Tibshirani, R. J. (1993) · doi:10.1007/978-1-4899-4541-9 · Cited by 21,230
Sokoloff, L., Reivich, M., Kennedy, C., Rosiers, M. H. D., Patlak, C. S., Pettigrew, K. D., Sakurada, O., & Shinohara, M. (1977) · Journal of Neurochemistry · doi:10.1111/j.1471-4159.1977.tb10649.x · Cited by 6,000 · cited 1×
“Another simplified quantitative method developed in the past is the autoradiographic method as first introduced by Sokoloff et al (1977) for non-gamma emitters in rats and later adjusted for human brain FDG studies by Huang et al (1980).”
MethodFrom RECIST to PERCIST: Evolving Considerations for PET Response Criteria in Solid Tumors
Wahl, R. L., Jacene, H., Kasamon, Y., & Lodge, M. A. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.057307 · Cited by 3,777 · cited 1×
“Meanwhile, increasing efforts are devoted toward transition of qualitative reads toward quantitative SUV assessment, especially for treatment response assessment (e.g. extensive review by Wahl et al (2009)).”
BackgroundSelf-citationGraphical Evaluation of Blood-to-Brain Transfer Constants from Multiple-Time Uptake Data
Patlak, C. S., Blasberg, R. G., & Fenstermacher, J. D. (1983) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1983.1 · Cited by 3,567 · cited 3×
“…linear graphical analysis modeling was employed at the voxel level, coupled with plasma input function estimation from the images, to estimate the tracer uptake rate Ki (slope) and the total blood distribution volume V (intercept) (Patlak et al 1983, Patlak and Blasberg 1985, Zhou et al 2010b).”
MethodPatlak, C. S., & Blasberg, R. G. (1985) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1038/jcbfm.1985.87 · Cited by 1,673 · cited 2×
“…linear graphical analysis modeling was employed at the voxel level, coupled with plasma input function estimation from the images, to estimate the tracer uptake rate Ki (slope) and the total blood distribution volume V (intercept) (Patlak et al 1983, Patlak and Blasberg 1985, Zhou et al 2010b).”
MethodPartial-Volume Effect in PET Tumor Imaging
Soret, M., Bacharach, S. L., & Buvat, I. (2007) · Journal of Nuclear Medicine · doi:10.2967/jnumed.106.035774 · Cited by 1,549 · cited 1×
“On the other hand, partial volume effects (PVE), which may also induce bias and loss of CNR in tumor imaging (Rousset et al 2007, Soret et al 2007, Erlandsson et al 2012), produce a similar impact in both SUV and Ki imaging (Freedman et al 2003).”
4D XCAT phantom for multimodality imaging research
Segars, W. P., Sturgeon, G., Mendonca, S., Grimes, J., & Tsui, B. M. W. (2010) · Medical Physics · doi:10.1118/1.3480985 · Cited by 1,287 · cited 1×
“Furthermore, the realistic XCAT human torso phantom was utilized to model the attenuation as well as the time-dependent activity maps for specific tissues and tumors commonly examined in oncology whole-body PET studies (Segars et al 2010).”
MethodSimultaneous PET-MRI: a new approach for functional and morphological imaging
Judenhofer, M. S., Wehrl, H. F., Newport, D. F., Catana, C., Siegel, S. B., Becker, M., Thielscher, A., Kneilling, M., Lichy, M. P., Eichner, M., et al. (2008) · Nature Medicine · doi:10.1038/nm1700 · Cited by 981 · cited 1×
“…of PET/MR imaging, the relatively increased time associated with multi-bed dynamic PET acquisitions can enable simultaneous multiple MR sequences (Judenhofer et al 2008), which usually also require lengthy acquisitions, to provide a wealth of multi-modality information, including but not limited…”
BackgroundNoninvasive determination of local cerebral metabolic rate of glucose in man
Huang, S. C., Phelps, M. E., Hoffman, E. J., Sideris, K., Selin, C. J., & Kuhl, D. E. (1980) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.1980.238.1.e69 · Cited by 925 · cited 1×
“Another simplified quantitative method developed in the past is the autoradiographic method as first introduced by Sokoloff et al (1977) for non-gamma emitters in rats and later adjusted for human brain FDG studies by Huang et al (1980).”
MethodSUV: standard uptake or silly useless value?
Keyes, J. W. (1995) · PubMed · Cited by 803
Jan, S., Benoit, D., Becheva, E., Carlier, T., Cassol, F., Descourt, P., Frisson, T., Grevillot, L., Guigues, L., Maigne, L., et al. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/001 · Cited by 794 · cited 1×
“Its ability to model time-dependent phenomena as well as its accurate description of all physics processes underlying emission tomography (Jan et al 2011) makes it an ideal solution for evaluation of PET/SPECT systems performance and optimization of acquisition protocols (Karakatsanis et al 2006,…”
BackgroundErlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733 · cited 1×
“On the other hand, partial volume effects (PVE), which may also induce bias and loss of CNR in tumor imaging (Rousset et al 2007, Soret et al 2007, Erlandsson et al 2012), produce a similar impact in both SUV and Ki imaging (Freedman et al 2003).”
A Systematic Review of the Factors Affecting Accuracy of SUV Measurements
Adams, M. C., Turkington, T. G., Wilson, J. M., & Wong, T. Z. (2010) · American Journal of Roentgenology · doi:10.2214/ajr.10.4923 · Cited by 662 · cited 2×
“In such a case, SUV will overestimate the metabolic rate of glucose in tumor (Leskinen-Kallio et al 1992, Weber et al 1999, Huang 2000, Adams et al 2010).”
BackgroundZasadny, K. R., & Wahl, R. L. (1993) · Radiology · doi:10.1148/radiology.189.3.8234714 · Cited by 635 · cited 4×
“The parametric Ki values in background regions of relatively constant but high activity have been shown to approach ‘zero’ unlike background SUV values (Zasadny and Wahl 1993), resulting in enhanced tumor contrast in Ki images.”
BackgroundInfluentialSelf-citationStrother, S. C., Casey, M. E., & Hoffman, E. J. (1990) · IEEE Transactions on Nuclear Science · doi:10.1109/23.106715 · Cited by 549 · cited 2×
“As a result, the NECR rises and therefore the SNR and the statistical quality of the acquired projection data are enhanced with respect to 3D acquisitions for high count rates (Strother et al 1990).”
BackgroundSTIR: software for tomographic image reconstruction release 2
Thielemans, K., Tsoumpas, C., Mustafovic, S., Beisel, T., Aguiar, P., Dikaios, N., & Jacobson, M. W. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/4/867 · Cited by 466
Huang, (. S.-C. (2000) · Nuclear Medicine and Biology · doi:10.1016/s0969-8051(00)00155-4 · Cited by 458 · cited 3×
“As a result, the SUV can be considered a semi-quantitative surrogate of the metabolic rate in certain cases in clinical FDG PET imaging (Hamberg et al 1994, Keyes 1995, Huang 2000).”
BackgroundPET/MRI: Paving the Way for the Next Generation of Clinical Multimodality Imaging Applications
Pichler, B. J., Kolb, A., Nägele, T., & Schlemmer, H.-P. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.061853 · Cited by 418 · cited 1×
“…enable simultaneous multiple MR sequences (Judenhofer et al 2008), which usually also require lengthy acquisitions, to provide a wealth of multi-modality information, including but not limited to radiation-free high resolution anatomical maps (Seemann 2005, Hofmann et al 2009, Pichler et al 2010).”
BackgroundThe dose uptake ratio as an index of glucose metabolism: useful parameter or oversimplification?
Hamberg, L. M., Hunter, G. J. S., Alpert, N. M., Choi, N. C., Babich, J. W., & Fischman, A. J. (1994) · PubMed · Cited by 395
Model-based scatter correction for fully 3D PET
Ollinger, J. M. (1996) · Physics in Medicine and Biology · doi:10.1088/0031-9155/41/1/012 · Cited by 393
Reproducibility of metabolic measurements in malignant tumors using FDG PET.
Weber, W., Ziegler, S. I., Thödtmann, R., Hanauske, A.-R., & Schwaiger, M. (1999) · PubMed · Cited by 388
Bergström, M., Eriksson, L., Bohm, C., Blomqvist, G., & Litton, J. (1983) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198302000-00008 · Cited by 388
In vivo assessment of glucose metabolism in hepatocellular carcinoma with FDG-PET.
Torizuka, T., Tamaki, N., Inokuma, T., Magata, Y., Sasayama, S., Yonekura, Y., Tanaka, A., Yamaoka, Y., Yamamoto, K., & Konishi, J. (1995) · PubMed · Cited by 357
Towards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343 · cited 1×
“…enable simultaneous multiple MR sequences (Judenhofer et al 2008), which usually also require lengthy acquisitions, to provide a wealth of multi-modality information, including but not limited to radiation-free high resolution anatomical maps (Seemann 2005, Hofmann et al 2009, Pichler et al 2010).”
BackgroundAdvantage of delayed whole-body FDG-PET imaging for tumour detection
Kubota, K., Itoh, M., Ozaki, K., Ono, S., Tashiro, M., Yamaguchi, K., Akaizawa, T., Yamada, K., & Fukuda, H. (2001) · European Journal of Nuclear Medicine · doi:10.1007/s002590100537 · Cited by 263 · cited 1×
“The PET acquisition associated with the SUV metric is static, i.e. every bed position is scanned once, typically around and/or after 1 h post-injection (Dahlbom et al 1992, Kubota et al 2001, Hustinx et al 2002, Townsend 2008).”
MethodKim, C. K., Gupta, N. C., Chandramouli, B., & Alavi, A. A. (1994) · PubMed · Cited by 229
Overview of the clinical effectiveness of positron emission tomography imaging in selected cancers
Facey, K., Bradbury, I., Laking, G., & Payne, E. (2007) · Health Technology Assessment · doi:10.3310/hta11440 · Cited by 219 · cited 1×
“The standardized uptake value (SUV) is currently widely employed in the clinic, as a surrogate of metabolic activity, across multiple bed positions, enabling whole-body imaging (Facey et al 2007, Castell and Cook 2008).”
MethodPositron Emission Tomography/Computed Tomography
Townsend, D. W. (2008) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2008.01.003 · Cited by 206 · cited 1×
“The PET acquisition associated with the SUV metric is static, i.e. every bed position is scanned once, typically around and/or after 1 h post-injection (Dahlbom et al 1992, Kubota et al 2001, Hustinx et al 2002, Townsend 2008).”
MethodWhole-body FDG-PET imaging in the management of patients with cancer
Hustinx, R., Bénard, F., & Alavi, A. (2002) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2002.29272 · Cited by 199 · cited 1×
“The PET acquisition associated with the SUV metric is static, i.e. every bed position is scanned once, typically around and/or after 1 h post-injection (Dahlbom et al 1992, Kubota et al 2001, Hustinx et al 2002, Townsend 2008).”
MethodWhole-body positron emission tomography: Part I. Methods and performance characteristics.
Dahlbom, M. L., Hoffman, E. J., Hoh, C. K., Schiepers, C. W., Rosenqvist, G., Hawkins, R. A., & Phelps, M. E. (1992) · PubMed · Cited by 199
Partial Volume Correction Strategies in PET
Rousset, O., Rahmim, A., Alavi, A., & Zaidi, H. (2007) · PET Clinics · doi:10.1016/j.cpet.2007.10.005 · Cited by 190 · cited 1×
“On the other hand, partial volume effects (PVE), which may also induce bias and loss of CNR in tumor imaging (Rousset et al 2007, Soret et al 2007, Erlandsson et al 2012), produce a similar impact in both SUV and Ki imaging (Freedman et al 2003).”
Self-citationSimplified measurement of deoxyglucose utilization rate.
Hunter, G. J. S., Hamberg, L. M., Alpert, N. M., Choi, N. C., & Fischman, A. J. (1996) · PubMed · Cited by 150
Dimitrakopoulou‐Strauss, A., Strauss, L. G., Schwarzbach, M., Burger, C., Heichel, T. O., Willeke, F., Mechtersheimer, G., & Lehnert, T. (2001) · PubMed · Cited by 147
Wiriyasermkul, P., Nagamori, S., Tominaga, H., Oriuchi, N., Kaira, K., Nakao, H., Kitashoji, T., Ohgaki, R., Tanaka, H., Endou, H., et al. (2012) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.103069 · Cited by 143
(2004) · PubMed · Cited by 141
Principles and Practice of Positron Emission Tomography.
Bisker, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.5.1801238 · Cited by 141 · cited 1×
“Clinical diagnosis and treatment response monitoring of localized and metastatic cancer malignancies have remarkably benefited from the advent of whole-body positron emission tomography, integrated with computed tomography (PET/CT) imaging (Wahl and Buchanan 2002).”
PET and MR Imaging: The Odd Couple or a Match Made in Heaven?
Catana, C., Guimarães, A. R., & Rosen, B. R. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.112771 · Cited by 140 · cited 1×
“Although the optimum way to deploy the technology is still under development (Catana et al 2013), a range of different MR sequences are available, including T1-, T2-, diffusionweighted and dynamic contrast-enhanced MR imaging (Moser et al 2008).”
BackgroundComparison of SUV and Patlak slope for monitoring of cancer therapy using serial PET scans
Freedman, N., Sundaram, S. K., Kurdziel, K., Carrasquillo, J. A., Whatley, M. A., Carson, J., Sellers, D., Libutti, S. K., Yang, J. C., & Bacharach, S. L. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0981-4 · Cited by 134 · cited 1×
“On the other hand, partial volume effects (PVE), which may also induce bias and loss of CNR in tumor imaging (Rousset et al 2007, Soret et al 2007, Erlandsson et al 2012), produce a similar impact in both SUV and Ki imaging (Freedman et al 2003).”
Dynamic whole-body PET parametric imaging: II. Task-oriented statistical estimation
Karakatsanis, N. A., Lodge, M. A., Zhou, Y., Wahl, R. L., & Rahmim, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/20/7419 · Cited by 120
Self-citationSugawara, Y., Zasadny, K. R., Grossman, H. B., Francis, I. R., Clarke, M. F., & Wahl, R. L. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap16249 · Cited by 119 · cited 1×
“…based on actual FDG kinetic micro-parameter and effective blood plasma volume values, as reported in literature and presented in table 2 (Torizuka et al 1995, Sugawara et al 1999, Dimitrakopoulou-Strauss et al 2001a, 2001b, 2004, 2006, Okazumi et al 2009, Strauss et al 2007, 2008, Qiao et al 2007).”
MethodSelf-citationTsoumpas, C., Turkheimer, F., & Thielemans, K. (2008) · Medical Physics · doi:10.1118/1.2885369 · Cited by 116 · cited 1×
“…(Karakatsanis et al 2013b) the extension of the proposed framework to the direct 4D parametric image reconstruction domain (Wang et al 2008, Tsoumpas et al 2008, Tang et al 2010, Wang and Qi 2010) to directly estimate the parametric images from the dynamic sinogram data in order to further…”
MethodDimitrakopoulou‐Strauss, A., Strauss, L. G., & Burger, C. (2001) · PubMed · Cited by 115
Dimitrakopoulou‐Strauss, A., Strauss, L. G., Burger, C., Rühl, A., Irngartinger, G., Stremmel, W., & Rudi, J. (2004) · PubMed · Cited by 104
Acceleration of the direct reconstruction of linear parametric images using nested algorithms
Wang, G., & Qi, J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/016 · Cited by 103 · cited 1×
“…extension of the proposed framework to the direct 4D parametric image reconstruction domain (Wang et al 2008, Tsoumpas et al 2008, Tang et al 2010, Wang and Qi 2010) to directly estimate the parametric images from the dynamic sinogram data in order to further limit the noise in the estimates…”
MethodBias in iterative reconstruction of low-statistics PET data: benefits of a resolution model
Walker, M. D., Asselin, M.-C., Julyan, P. J., Feldmann, M., Talbot, P. S., Jones, T., & Matthews, J. C. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/4/004 · Cited by 102
Maximuma posteriorireconstruction of the Patlak parametric image from sinograms in dynamic PET
Wang, G., Fu, L., & Qi, J. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/3/006 · Cited by 91 · cited 1×
“…we are investigating (Karakatsanis et al 2013b) the extension of the proposed framework to the direct 4D parametric image reconstruction domain (Wang et al 2008, Tsoumpas et al 2008, Tang et al 2010, Wang and Qi 2010) to directly estimate the parametric images from the dynamic sinogram data in…”
MethodCarbon-11-methionine and PET is an effective method to image head and neck cancer.
Leskinen-Kallio, S., Någren, K., Lehikoinen, P., Ruotsalainen, U., Teräs, M., & Joensuu, H. (1992) · PubMed · Cited by 89
Magnetic resonance imaging methodology
Moser, E., Stadlbauer, A., Windischberger, C., Quick, H. H., & Ladd, M. E. (2008) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-0938-3 · Cited by 88 · cited 1×
“Although the optimum way to deploy the technology is still under development (Catana et al 2013), a range of different MR sequences are available, including T1-, T2-, diffusionweighted and dynamic contrast-enhanced MR imaging (Moser et al 2008).”
BackgroundSadato, N., Tsuchida, T., Nakaumra, S., Waki, A., Uematsu, H., Takahashi, N., Hayashi, N., Yonekura, Y., & Ishii, Y. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050256 · Cited by 86 · cited 3×
“Subsequent analysis using an appropriate kinetic model can result in more quantitative parameter estimates, compared to SUV imaging (Wong and Hicks 1994, Sadato et al 1998, Dimitrakopoulou-Strauss et al 2001a, 2001b, 2004, 2006).”
BackgroundMethodWhole-Body PET/MRI: The Future in Oncological Imaging
Seemann, M. D. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400512 · Cited by 84 · cited 1×
“…enable simultaneous multiple MR sequences (Judenhofer et al 2008), which usually also require lengthy acquisitions, to provide a wealth of multi-modality information, including but not limited to radiation-free high resolution anatomical maps (Seemann 2005, Hofmann et al 2009, Pichler et al 2010).”
BackgroundQuantitative techniques in 18FDG PET scanning in oncology
Castell, F. A., & Cook, G. (2008) · British Journal of Cancer · doi:10.1038/sj.bjc.6604330 · Cited by 80 · cited 2×
“The proposed approach, aside from covering a large axial field-ofview, enables truly quantitative dynamic imaging which can be crucial in both diagnosis and treatment response monitoring (Castell and Cook 2008).”
BackgroundMethodKIM, C. K., & Gupta, N. C. (1996) · Nuclear Medicine Communications · doi:10.1097/00006231-199610000-00011 · Cited by 72 · cited 2×
“…relative to the metabolized tracer, and (ii) time integral of plasma tracer concentration is proportional to the injected amount of tracer normalized by the body weight (or lean body mass (LBM) or body surface area) (Zasadny and Wahl 1993, Kim et al 1994, Kim and Gupta 1996, Sadato et al 1998).”
BackgroundStrauss, L. G., Klippel, S., Pan, L., Schönleben, K., Haberkorn, U., & Dimitrakopoulou‐Strauss, A. (2007) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-006-0319-8 · Cited by 68 · cited 1×
“…based on actual FDG kinetic micro-parameter and effective blood plasma volume values, as reported in literature and presented in table 2 (Torizuka et al 1995, Sugawara et al 1999, Dimitrakopoulou-Strauss et al 2001a, 2001b, 2004, 2006, Okazumi et al 2009, Strauss et al 2007, 2008, Qiao et al 2007).”
MethodNg, J. M., Azuma, K., Kelley, C., Pencek, R., Radikova, Z., Laymon, C., Price, J., Goodpaster, B. H., & Kelley, D. E. (2012) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00282.2012 · Cited by 67 · cited 1×
“An interesting study of glucose metabolism in adipose tissue by Ng et al (2012) involved only two beds and proposing sequential dynamic scans across the beds, each lasting ∼45 min at the given bed position.”
BackgroundImpact of Angiogenesis-Related Gene Expression on the Tracer Kinetics of18F-FDG in Colorectal Tumors
Strauss, L. G., Koczan, D., Klippel, S., Pan, L., Cheng, C., Willis, S., Haberkorn, U., & Dimitrakopoulou‐Strauss, A. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.051599 · Cited by 67 · cited 1×
“…based on actual FDG kinetic micro-parameter and effective blood plasma volume values, as reported in literature and presented in table 2 (Torizuka et al 1995, Sugawara et al 1999, Dimitrakopoulou-Strauss et al 2001a, 2001b, 2004, 2006, Okazumi et al 2009, Strauss et al 2007, 2008, Qiao et al 2007).”
MethodMulti-graphical analysis of dynamic PET
Zhou, Y., Ye, W., Brašić, J. R., & Wong, D. F. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.028 · Cited by 62 · cited 3×
“…linear graphical analysis modeling was employed at the voxel level, coupled with plasma input function estimation from the images, to estimate the tracer uptake rate Ki (slope) and the total blood distribution volume V (intercept) (Patlak et al 1983, Patlak and Blasberg 1985, Zhou et al 2010b).”
MethodSelf-citationDirect 4D reconstruction of parametric images incorporating anato-functional joint entropy
Tang, J., Kuwabara, H., Wong, D. F., & Rahmim, A. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/15/005 · Cited by 55 · cited 1×
“…et al 2013b) the extension of the proposed framework to the direct 4D parametric image reconstruction domain (Wang et al 2008, Tsoumpas et al 2008, Tang et al 2010, Wang and Qi 2010) to directly estimate the parametric images from the dynamic sinogram data in order to further limit the noise in…”
Self-citationEnhanced FDG-PET tumor imaging with correlation-coefficient filtered influx-constant images.
Zasadny, K. R., & Wahl, R. L. (1996) · PubMed · Cited by 53
Self-citationFour-Dimensional Image Reconstruction Strategies in Cardiac-Gated and Respiratory-Gated PET Imaging
Rahmim, A., Tang, J., & Zaidi, H. (2012) · PET Clinics · doi:10.1016/j.cpet.2012.10.005 · Cited by 48 · cited 1×
“…periodic motion-induced artifacts can be limited with gated acquisition (Nehmeh 2013, Nekolla et al 2013) and advanced 4D image reconstruction (Rahmim et al 2013), many other types of patient motion are irregular, involuntary and more likely to occur during long dynamic PET acquisitions and…”
BackgroundSelf-citationParameterization of a model-based 3-D PET scatter correction
Wollenweber, S. D. (2002) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2002.1039554 · Cited by 47 · cited 1×
“…by Spinks and Bastin (2008) have shown in cardiac studies that GE Discovery RX scatter correction method by Bergstorm et al (1983) in 2D mode is accurate and comparable with the method of Wollenweber (2002) in 3D, provided no excessive uptake is present adjacent to the ROI in the case of 3D mode.”
MethodA fully 3D iterative image reconstruction algorithm incorporating data corrections
Iatrou, M., Ross, S. G., Manjeshwar, R. M., & Stearns, C. W. (2005) · IEEE Symposium Conference Record Nuclear Science 2004. · doi:10.1109/nssmic.2004.1462761 · Cited by 45 · cited 2×
“…in fact, for scatter estimation and correction, the analytical deconvolution technique of Bergstorm et al (1983) was used for the 2D acquisition while for 3D mode a model-based algorithm was implemented by Iatrou et al (2004, 2006) based on Ollinger’s (1996) and Wollenweber’s (2002) methods.”
MethodDynamic Multi-Bed FDG PET imaging: Feasibility and optimization
Karakatsanis, N. A., Lodge, M. A., Zhou, Y., Mhlanga, J. C., Chaudhry, M. Q., Tahari, A. K., Segars, W. P., Wahl, R. L., & Rahmim, A. (2011) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2011.6153735 · Cited by 44 · cited 3×
“The total acquisition time for the 4D whole-body PET acquisition is ∼48 min and is implemented in two subsequent time phases (Karakatsanis et al 2011, 2012b): (i) an initial 6 min single-bed dynamic scan over the cardiac region comprised of 24 frames with the following time sequence: (12 frames) ×…”
MethodSelf-citationInitial evaluation of dynamic human imaging using18F-FRP170 as a new PET tracer for imaging hypoxia
Kaneta, T., Takai, Y., Iwata, R., Hakamatsuka, T., Yasuda, H., Nakayama, K., Ishikawa, Y., Watanuki, S., Furumoto, S., Funaki, Y., et al. (2007) · Annals of Nuclear Medicine · doi:10.1007/bf03033987 · Cited by 43 · cited 1×
“Kaneta et al (2007) also conducted multi-bed dynamic acquisition of human subjects (0–90 min postinjection) in the context of imaging hypoxia using 18F-FRP170, involving sequential wholebody acquisitions, each lasting for 12 min (six beds × 2 min/bed).”
MethodSimplified kinetic analysis of tumor 18F-FDG uptake: a dynamic approach.
Sundaram, S. K., Freedman, N. M. T., Carrasquillo, J. A., Carson, J., Whatley, M. A., Libutti, S. K., Sellers, D., & Bacharach, S. L. (2004) · PubMed · Cited by 40
3D implementation of Scatter Estimation in 3D PET
Iatrou, M., Manjeshwar, R. M., Ross, S. G., Thielemans, K., & Stearns, C. W. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2006.354338 · Cited by 33 · cited 2×
“…in fact, for scatter estimation and correction, the analytical deconvolution technique of Bergstorm et al (1983) was used for the 2D acquisition while for 3D mode a model-based algorithm was implemented by Iatrou et al (2004, 2006) based on Ollinger’s (1996) and Wollenweber’s (2002) methods.”
MethodThe quantification with FDG as seen by a physician
Galli, G., Indovina, L., Calcagni, M. L., Mansi, L., & Giordano, A. (2013) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2013.06.009 · Cited by 23 · cited 1×
“It was recently demonstrated in a review by Galli et al (2013) that the accuracy of the autoradiographic method relies on the assumption that the free (non-phosphorylated) amount of glucose tracer left in the tissue at the time of scan is negligible to the bound or phosphorylated amount.”
BackgroundOptimized sampling and parameter estimation for quantification in whole body PET
Ho‐Shon, K., Feng, D. D., Hawkins, R. A., Meikle, S. R., FULHAM, M. J., & Li, X. (1996) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.536903 · Cited by 21 · cited 1×
“A particular study by Ho-Shon et al (1996) was notable as it proposed a method to optimize multi-bed dynamic PET acquisitions, based on a statistical Bayesian regression method.”
MethodQuantitative whole-body parametric PET imaging incorporating a generalized Patlak model
Karakatsanis, N. A., Zhou, Y., Lodge, M. A., Casey, M., Wahl, R. L., & Rahmim, A. (2013) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2013.6829042 · Cited by 21 · cited 7×
“The performance of the WR-based methods, presented in the following section as well as in the companion paper (Karakatsanis et al 2013a), rely on the selection of an ‘appropriate’ WR reference value to best match the two clusters with the statistical quality properties assumed above.”
MethodResultInfluentialSelf-citationWong, W., & Hicks, K. (1994) · PubMed · Cited by 20
Motion Artifacts in Oncological and Cardiac PET Imaging
Dinges, J., Nekolla, S. G., & Bundschuh, R. A. (2012) · PET Clinics · doi:10.1016/j.cpet.2012.10.001 · Cited by 12 · cited 2×
“…be limited with gated acquisition (Nehmeh 2013, Nekolla et al 2013) and advanced 4D image reconstruction (Rahmim et al 2013), many other types of patient motion are irregular, involuntary and more likely to occur during long dynamic PET acquisitions and at random time points (Dinges et al 2013).”
BackgroundBurger, I. A., Burger, C., Berthold, T., & Buck, A. (2011) · Nuclear Medicine and Biology · doi:10.1016/j.nucmedbio.2011.02.003 · Cited by 10 · cited 1×
“A recent evaluation of the method by Burger et al (2011) employing this technique demonstrated high correlation between the autoradiographically estimated Ki and Patlak Ki imaging, the latter considered the golden standard.”
MethodClinical Impact of Cardiac-Gated PET Imaging
Nekolla, S. G., Dinges, J., & Rischpler, C. (2012) · PET Clinics · doi:10.1016/j.cpet.2012.10.002 · Cited by 7 · cited 1×
“Although periodic motion-induced artifacts can be limited with gated acquisition (Nehmeh 2013, Nekolla et al 2013) and advanced 4D image reconstruction (Rahmim et al 2013), many other types of patient motion are irregular, involuntary and more likely to occur during long dynamic PET acquisitions…”
BackgroundKarakatsanis, N. A., Lodge, M. A., Mohy‐ud‐Din, H., Tahari, A. K., Zhou, Y., Wahl, R. L., & Rahmim, A. (2012) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2012.6551920 · Cited by 4 · cited 2×
“The total acquisition time for the 4D whole-body PET acquisition is ∼48 min and is implemented in two subsequent time phases (Karakatsanis et al 2011, 2012b): (i) an initial 6 min single-bed dynamic scan over the cardiac region comprised of 24 frames with the following time sequence: (12 frames) ×…”
MethodSelf-citation
Cited by
Cherry, S. R., Jones, T., Karp, J. S., Qi, J., Moses, W. W., & Badawi, R. D. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.184028 · Cited by 763
“Total-body dynamic imaging (4,5), which to date has been hampered by poor SNR and sparse temporal sampling due to the need for multiple bed positions, will be much more practical, and the high SNR means that even data from very short frames will carry high-quality information for kinetic analysis.”
BackgroundIterative PET Image Reconstruction Using Convolutional Neural Network Representation
Gong, K., Guan, J., Kim, K., Zhang, X., Yang, J., Seo, Y., El Fakhri, G., Qi, J., & Li, Q. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2869871 · Cited by 274
Dynamic whole-body PET imaging: principles, potentials and applications
Rahmim, A., Lodge, M. A., Karakatsanis, N. A., Panin, V. Y., Zhou, Y., McMillan, A., Cho, S., Zaidi, H., Casey, M. E., & Wahl, R. L. (2019) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-018-4153-6 · Cited by 273
Self-citationShiri, I., Rahmim, A., Ghaffarian, P., Geramifar, P., Abdollahi, H., & Bitarafan-Rajabi, A. (2017) · European Radiology · doi:10.1007/s00330-017-4859-z · Cited by 204
Self-citationDimitrakopoulou-Strauss, A., Pan, L., & Sachpekidis, C. (2021) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-020-04843-6 · Cited by 203
Metadata
- Authors
- Karakatsanis, N. A., Lodge, M. A., Tahari, A. K., Zhou, Y., Wahl, R. L., & Rahmim, A.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-09-30
- Volume
- 58
- Issue
- 20
- Pages
- 7391-7418
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2050946937
- Cited by
- 247
- References
- 74
- FWCI
- 9.27
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.