Relative biological effectiveness (RBE) values for proton beam therapy. Variations as a function of biological endpoint, dose, and linear energy transfer
Open accessThe DOI matches its Crossref record; 137 of the 137 references it cites were found in a registry or an index.
Abstract
Proton therapy treatments are based on a proton RBE (relative biological effectiveness) relative to high-energy photons of 1.1. The use of this generic, spatially invariant RBE within tumors and normal tissues disregards the evidence that proton RBE varies with linear energy transfer (LET), physiological and biological factors, and clinical endpoint. Based on the available experimental data from published literature, this review analyzes relationships of RBE with dose, biological endpoint and physical properties of proton beams. The review distinguishes between endpoints relevant for tumor control probability and those potentially relevant for normal tissue complication. Numerous endpoints and experiments on sub-cellular damage and repair effects are discussed. Despite the large amount of data, considerable uncertainties in proton RBE values remain. As an average RBE for cell survival in the center of a typical spread-out Bragg peak (SOBP), the data support a value of ~1.15 at 2 Gy/fraction. The proton RBE increases with increasing LETd and thus with depth in an SOBP from ~1.1 in the entrance region, to ~1.15 in the center, ~1.35 at the distal edge and ~1.7 in the distal fall-off (when averaged over all cell lines, which may not be clinically representative). For small modulation widths the values could be increased. Furthermore, there is a trend of an increase in RBE as (α/β)x decreases. In most cases the RBE also increases with decreasing dose, specifically for systems with low (α/β)x. Data on RBE for endpoints other than clonogenic cell survival are too diverse to allow general statements other than that the RBE is, on average, in line with a value of ~1.1. This review can serve as a source for defining input parameters for applying or refining biophysical models and to identify endpoints where additional radiobiological data are needed in order to reduce the uncertainties to clinically acceptable levels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Evidence for a lack of DNA double-strand break repair in human cells exposed to very low x-ray doses
Rothkamm, K., & Löbrich, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0830918100 · Cited by 1,645 · cited 24×
“Green et al (2001) compared proton and photon induced DNA damage not distinguishing between SSB and DSB.”
BackgroundInfluentialRelative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Self-citationRange uncertainties in proton therapy and the role of Monte Carlo simulations
Paganetti, H. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/11/r99 · Cited by 1,325
Self-citationTwo genetic hits (more or less) to cancer
Knudson, A. G. (2001) · Nature Reviews Cancer · doi:10.1038/35101031 · Cited by 1,127
Bentzen, S. M. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1950 · Cited by 1,096
New insights on cell death from radiation exposure
Prise, K. M., Schettino, G., Folkard, M., & Held, K. D. (2005) · The Lancet Oncology · doi:10.1016/s1470-2045(05)70246-1 · Cited by 382
Elsässer, T., Weyrather, W. K., Friedrich, T., Durante, M., Iancu, G., Krämer, M., Kragl, G., Brons, S., Winter, M., Weber, K.-J., et al. (2010) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.05.014 · Cited by 351
Enzymatic Processing of Radiation-Induced Free Radical Damage in DNA
Wallace, S. S. (1998) · Radiation Research · doi:10.2307/3579809 · Cited by 334
Friedrich, T., Scholz, U., ElsaSser, T., Durante, M., & Scholz, M. (2013) · Journal of Radiation Research · doi:10.1093/jrr/rrs114 · Cited by 287
Induction and Repair of Clustered DNA Lesions: What Do We Know So Far?
Georgakilas, A. G., O'Neill, P., & Stewart, R. D. (2013) · Radiation Research · doi:10.1667/rr3041.1 · Cited by 278
Cited by
Proton therapy – Present and future
Mohan, R., & Grosshans, D. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2016.11.006 · Cited by 608
Charged-particle therapy in cancer: clinical uses and future perspectives
Durante, M., Orecchia, R., & Loeffler, J. S. (2017) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2017.30 · Cited by 484
The linear quadratic model: usage, interpretation and challenges
McMahon, S. J. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aaf26a · Cited by 440
McNamara, A. L., Schuemann, J., & Paganetti, H. (2015) · Physics in Medicine and Biology · doi:10.1088/0031-9155/60/21/8399 · Cited by 345
Self-citationNuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Self-citationPaganetti, H., Blakely, E., Carabe‐Fernandez, A., Carlson, D. J., Das, I. J., Dong, L., Grosshans, D., Held, K. D., Mohan, R., Moiseenko, V., et al. (2019) · Medical Physics · doi:10.1002/mp.13390 · Cited by 310
Self-citationBiological effects in normal cells exposed to FLASH dose rate protons
Buonanno, M., Grilj, V., & Brenner, D. J. (2019) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2019.02.009 · Cited by 306
Peeler, C. R., Mirkovic, D., Titt, U., Blanchard, P., Gunther, J. R., Mahajan, A., Mohan, R., & Grosshans, D. R. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.11.001 · Cited by 271
Tinganelli, W., & Durante, M. (2020) · Cancers · doi:10.3390/cancers12103022 · Cited by 267
Tommasino, F., & Durante, M. (2015) · Cancers · doi:10.3390/cancers7010353 · Cited by 252
“This seems to be a relevant approach for an accurate calculation of NTCP.”
BackgroundResultInfluentialA review of proton therapy – Current status and future directions
Mohan, R. (2022) · Precision Radiation Oncology · doi:10.1002/pro6.1149 · Cited by 248
“1.[10,9] This value of RBE is based on an average of the results”
BackgroundRBE and related modeling in carbon-ion therapy
Karger, C. P., & Peschke, P. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9102 · Cited by 211
Mohamad, O., Sishc, B., Saha, J., Pompos, A., Rahimi, A., Story, M., Davis, A., & Kim, D. W. (2017) · Cancers · doi:10.3390/cancers9060066 · Cited by 200
“However, because past experiments were conducted under a broad range of inconsistent conditions and because of the large variability of results, this value is not considered definitive [8,16,17].”
BackgroundClustered DNA Double-Strand Breaks: Biological Effects and Relevance to Cancer Radiotherapy
Nickoloff, J. A., Sharma, N., & Taylor, L. (2020) · Genes · doi:10.3390/genes11010099 · Cited by 196
“radiation; however, it is now understood that the LET of protons increases at the distal end of the Bragg peak [66,67].”
BackgroundHaas-Kogan, D., Indelicato, D., Paganetti, H., Esiashvili, N., Mahajan, A., Yock, T., Flampouri, S., MacDonald, S., Fouladi, M., Stephen, K., et al. (2018) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2018.01.013 · Cited by 182
Self-citationWeber, D. C., Malyapa, R., Albertini, F., Bolsi, A., Kliebsch, U., Walser, M., Pica, A., Combescure, C., Lomax, A. J., & Schneider, R. (2016) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2016.05.011 · Cited by 178
Roadmap: proton therapy physics and biology
Paganetti, H., Beltran, C., Both, S., Dong, L., Flanz, J., Furutani, K., Grassberger, C., Grosshans, D. R., Knopf, A.-C., Langendijk, J. A., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abcd16 · Cited by 175
“For normal tissue the RBE can be substantially higher (Paganetti 2014), which is currently neglected in treatment planning.”
BackgroundInfluentialSelf-citationPhysics and biomedical challenges of cancer therapy with accelerated heavy ions
Durante, M., Debus, J., & Loeffler, J. S. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00368-5 · Cited by 170
Guan, F., Bronk, L., Titt, U., Lin, S. H., Mirkovic, D., Kerr, M. D., Zhu, X. R., Dinh, J., Sobieski, M., Stephan, C., et al. (2015) · Scientific Reports · doi:10.1038/srep09850 · Cited by 167
Stewart, R. D., Streitmatter, S. W., Argento, D. C., Kirkby, C., Goorley, J. T., Moffitt, G., Jevremovic, T., & Sandison, G. A. (2015) · Physics in Medicine & Biology · doi:10.1088/0031-9155/60/21/8249 · Cited by 103
Applied nuclear physics at the new high-energy particle accelerator facilities
Durante, M., Golubev, A., Park, W.-Y., & Trautmann, C. (2019) · Physics Reports · doi:10.1016/j.physrep.2019.01.004 · Cited by 72
Enhancing Proton Therapy Efficacy Through Nanoparticle-Mediated Radiosensitization
Ma, J., Shen, H., & Mi, Z. (2024) · Cells · doi:10.3390/cells13221841 · Cited by 23
In vivo validation of the BIANCA biophysical model: benchmarking against rat spinal cord RBE data
Carante, M. P., Aricò, G., Ferrari, A., Karger, C. P., Kozlowska, W., Mairani, A., Sala, P., & Ballarini, F. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21113973 · Cited by 21
Metadata
- Authors
- Paganetti, H.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-10-31
- Volume
- 59
- Issue
- 22
- Pages
- R419-R472
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2083770395
- Cited by
- 915
- References
- 137
- FWCI
- 34.65
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.