Comparing gold nano-particle enhanced radiotherapy with protons, megavoltage photons and kilovoltage photons: a Monte Carlo simulation
The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Gold nanoparticles (GNPs) have shown potential to be used as a radiosensitizer for radiation therapy. Despite extensive research activity to study GNP radiosensitization using photon beams, only a few studies have been carried out using proton beams. In this work Monte Carlo simulations were used to assess the dose enhancement of GNPs for proton therapy. The enhancement effect was compared between a clinical proton spectrum, a clinical 6 MV photon spectrum, and a kilovoltage photon source similar to those used in many radiobiology lab settings. We showed that the mechanism by which GNPs can lead to dose enhancements in radiation therapy differs when comparing photon and proton radiation. The GNP dose enhancement using protons can be up to 14 and is independent of proton energy, while the dose enhancement is highly dependent on the photon energy used. For the same amount of energy absorbed in the GNP, interactions with protons, kVp photons and MV photons produce similar doses within several nanometers of the GNP surface, and differences are below 15% for the first 10 nm. However, secondary electrons produced by kilovoltage photons have the longest range in water as compared to protons and MV photons, e.g. they cause a dose enhancement 20 times higher than the one caused by protons 10 μm away from the GNP surface. We conclude that GNPs have the potential to enhance radiation therapy depending on the type of radiation source. Proton therapy can be enhanced significantly only if the GNPs are in close proximity to the biological target.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Agostinelli, S., Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce, P., Asai, M., Axen, D., Banerjee, S., Barrand, G., et al. (2003) · Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment · doi:10.1016/s0168-9002(03)01368-8 · Cited by 25,106
Determining the Size and Shape Dependence of Gold Nanoparticle Uptake into Mammalian Cells
Chithrani, B. D., Ghazani, A. A., & Chan, W. C. W. (2006) · Nano Letters · doi:10.1021/nl052396o · Cited by 4,879 · cited 1×
“We chose to perform simulation studies using a 50 nm GNP because GNPs at this size have shown an optimized cellular uptake (Chithrani et al 2006).”
MethodThe use of gold nanoparticles to enhance radiotherapy in mice
Hainfeld, J. F., Slatkin, D. N., & Smilowitz, H. M. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/18/n03 · Cited by 1,638 · cited 1×
“Significant increase in one-year survival of tumor bearing mice has been observed when the mice are irradiated with kilovoltage x-rays with intravenous injection of GNPs as compared to radiation alone (Hainfeld et al 2004, 2013, Chattopadhyay et al 2012, Joh et al 2013).”
MethodRelative biological effectiveness (RBE) values for proton beam therapy
Paganetti, H., Niemierko, A., Ancukiewicz, M., Gerweck, L. E., Goitein, M., Loeffler, J. S., & Suit, H. D. (2002) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/s0360-3016(02)02754-2 · Cited by 1,364
Self-citationTOPAS: An innovative proton Monte Carlo platform for research and clinical applications
Perl, J., Shin, J., Schümann, J., Faddegon, B., & Paganetti, H. (2012) · Medical Physics · doi:10.1118/1.4758060 · Cited by 1,140 · cited 1×
“Simulations were carried out using TOPAS (TOol for PArticle Simulation) (Perl et al 2012), a Monte Carlo tool layered on top of Geant4 (Asai 2006).”
MethodSelf-citationGold Nanoparticles as Radiation Sensitizers in Cancer Therapy
Chithrani, D. B., Jelveh, S., Jalali, F., van Prooijen, M., Allen, C., Bristow, R. G., Hill, R. P., & Jaffray, D. A. (2010) · Radiation Research · doi:10.1667/rr1984.1 · Cited by 669 · cited 2×
“Gold nanoparticles (GNPs) have attracted the most attention owing to their high density, biocompatibility and potential for targeted surface modification (Chithrani et al 2010).”
BackgroundINCERTI, S., BALDACCHINO, G., BERNAL, M., CAPRA, R., CHAMPION, C., FRANCIS, Z., GUÈYE, P., MANTERO, A., MASCIALINO, B., MORETTO, P., et al. (2010) · International Journal of Modeling, Simulation, and Scientific Computing · doi:10.1142/s1793962310000122 · Cited by 538 · cited 1×
“The ‘Geant4-DNA’ physics package, which tracks electrons down to an energy of 7.4 eV, was used to provide the best accuracy to track the low-energy secondary electrons in water (Incerti et al 2010).”
MethodInfluentialPhysical basis and biological mechanisms of gold nanoparticle radiosensitization
Butterworth, K. T., McMahon, S. J., Currell, F. J., & Prise, K. M. (2012) · Nanoscale · doi:10.1039/c2nr31227a · Cited by 478 · cited 2×
“…characteristics of secondary electrons produced through interactions between photon beams and GNPs, as well as the spatial dose deposition by these electrons in the vicinity of GNPs (Jones et al 2010, Leung et al 2011, McMahon et al 2011a, 2011b, Lechtman et al 2011, 2013, Butterworth et al 2012).”
BackgroundSelf-citationCell-Specific Radiosensitization by Gold Nanoparticles at Megavoltage Radiation Energies
Jain, S., Coulter, J. A., Hounsell, A. R., Butterworth, K. T., McMahon, S. J., Hyland, W. B., Muir, M. F., Dickson, G. R., Prise, K. M., Currell, F. J., et al. (2011) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2010.08.044 · Cited by 475
Self-citationKrämer, M., & Scholz, M. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/314 · Cited by 453 · cited 1×
“Then amount of energy in infinitesimally small voxels are converted into a probability of lethal event, and those voxel probabilities are summed-up to produce a probability of cell survival (Krämer and Scholz 2000).”
Background
Cited by
Gold nanoparticles for applications in cancer radiotherapy: Mechanisms and recent advancements
Her, S., Jaffray, D. A., & Allen, C. (2017) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.12.012 · Cited by 865
Bernal, M. A., Bordage, M. C., Brown, J. M. C., Davídková, M., Delage, E., El Bitar, Z., Enger, S. A., Francis, Z., Guatelli, S., Ivanchenko, V. N., et al. (2015) · Physica Medica · doi:10.1016/j.ejmp.2015.10.087 · Cited by 536
Gold Nanoparticles as Radiosensitizers in Cancer Radiotherapy
Chen, Y., Yang, J., Fu, S., & Wu, J. (2020) · International Journal of Nanomedicine · doi:10.2147/ijn.s272902 · Cited by 319
Dou, Y., Guo, Y., Li, X., Li, X., Wang, S., Wang, L., Lv, G., Zhang, X., Wang, H., Gong, X., et al. (2016) · ACS Nano · doi:10.1021/acsnano.5b07473 · Cited by 288
Roadmap to Clinical Use of Gold Nanoparticles for Radiation Sensitization
Schuemann, J., Berbeco, R., Chithrani, D. B., Cho, S. H., Kumar, R., McMahon, S. J., Sridhar, S., & Krishnan, S. (2016) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2015.09.032 · Cited by 253
Self-citationNanoparticle radio-enhancement: principles, progress and application to cancer treatment
Kuncic, Z., & Lacombe, S. (2018) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa99ce · Cited by 236
“Modeling studies of incident protons radiation effects with AuNPs were carried out by Lin et al (2014, 2015).”
BackgroundGold Nanoparticles as a Potent Radiosensitizer: A Transdisciplinary Approach from Physics to Patient
Penninckx, S., Heuskin, A.-C., Michiels, C., & Lucas, S. (2020) · Cancers · doi:10.3390/cancers12082021 · Cited by 181
“[46] simulated the number of electrons emitted from a 50 nm GNP after X-ray exposition and reported very low values in the 10−5–10−4 range per incoming photon at best.”
BackgroundHullo, M., Grall, R., Perrot, Y., Mathé, C., Ménard, V., Yang, X., Lacombe, S., Porcel, E., Villagrasa, C., Chevillard, S., et al. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22094436 · Cited by 48
Enhancing Proton Therapy Efficacy Through Nanoparticle-Mediated Radiosensitization
Ma, J., Shen, H., & Mi, Z. (2024) · Cells · doi:10.3390/cells13221841 · Cited by 23
Metadata
- Authors
- Lin, Y., McMahon, S. J., Scarpelli, M., Paganetti, H., & Schuemann, J.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-11-21
- Volume
- 59
- Issue
- 24
- Pages
- 7675-7689
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2056355209
- Cited by
- 190
- References
- 32
- FWCI
- 12.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.