A radiomics model from joint FDG-PET and MRI texture features for the prediction of lung metastases in soft-tissue sarcomas of the extremities
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
This study aims at developing a joint FDG-PET and MRI texture-based model for the early evaluation of lung metastasis risk in soft-tissue sarcomas (STSs). We investigate if the creation of new composite textures from the combination of FDG-PET and MR imaging information could better identify aggressive tumours. Towards this goal, a cohort of 51 patients with histologically proven STSs of the extremities was retrospectively evaluated. All patients had pre-treatment FDG-PET and MRI scans comprised of T1-weighted and T2-weighted fat-suppression sequences (T2FS). Nine non-texture features (SUV metrics and shape features) and forty-one texture features were extracted from the tumour region of separate (FDG-PET, T1 and T2FS) and fused (FDG-PET/T1 and FDG-PET/T2FS) scans. Volume fusion of the FDG-PET and MRI scans was implemented using the wavelet transform. The influence of six different extraction parameters on the predictive value of textures was investigated. The incorporation of features into multivariable models was performed using logistic regression. The multivariable modeling strategy involved imbalance-adjusted bootstrap resampling in the following four steps leading to final prediction model construction: (1) feature set reduction; (2) feature selection; (3) prediction performance estimation; and (4) computation of model coefficients. Univariate analysis showed that the isotropic voxel size at which texture features were extracted had the most impact on predictive value. In multivariable analysis, texture features extracted from fused scans significantly outperformed those from separate scans in terms of lung metastases prediction estimates. The best performance was obtained using a combination of four texture features extracted from FDG-PET/T1 and FDG-PET/T2FS scans. This model reached an area under the receiver-operating characteristic curve of 0.984 ± 0.002, a sensitivity of 0.955 ± 0.006, and a specificity of 0.926 ± 0.004 in bootstrapping evaluations. Ultimately, lung metastasis risk assessment at diagnosis of STSs could improve patient outcomes by allowing better treatment adaptation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Textural Features for Image Classification
Haralick, R. M., Shanmugam, K., & Dinstein, I. (1973) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1973.4309314 · Cited by 22,886
Least squares quantization in PCM
Lloyd, S. (1982) · IEEE Transactions on Information Theory · doi:10.1109/tit.1982.1056489 · Cited by 15,836 · cited 1×
“…define decision thresholds in the volume such that the number of voxels with reconstructed level rk is the same in the quantized volume for all k (i.e. for all gray levels), whereas Lloyd-Max quantization attempts to minimize the mean-squared quantization error of the output (Max 1960, Lloyd 1982).”
BackgroundSiegel, R., Ma, J., Zou, Z., & Jemal, A. (2014) · CA: A Cancer Journal for Clinicians · doi:10.3322/caac.21208 · Cited by 11,499
Radiomics: extracting more information from medical images using advanced feature analysis
Lambin, P., Rios-Velazquez, E., Leijenaar, R., Carvalho, S., van Stiphout, R. G. P. M., Granton, P., Zegers, C. M. L., Gillies, R., Boellard, R., Dekker, A., et al. (2012) · European Journal of Cancer · doi:10.1016/j.ejca.2011.11.036 · Cited by 6,084
Decoding tumour phenotype by noninvasive imaging using a quantitative radiomics approach
Aerts, H. J. W. L., Velazquez, E. R., Leijenaar, R. T. H., Parmar, C., Grossmann, P., Carvalho, S., Bussink, J., Monshouwer, R., Haibe-Kains, B., Rietveld, D., et al. (2014) · Nature Communications · doi:10.1038/ncomms5006 · Cited by 5,132 · cited 8×
“More than 50 sub-types are recognized by the World Health Organization (WHO). STSs are relatively uncommon, representing approximately 0.7% of new adult malignancies in the United States (Siegel et al 2014). The majority of new cases are either intermediate or high-grade tumours and may arise in virtually all sites, w…”
MethodInfluentialFisher, R. A. (1936) · BMJ · doi:10.1136/bmj.1.3923.554-a · Cited by 4,980
Detecting Novel Associations in Large Data Sets
Reshef, D. N., Reshef, Y. A., Finucane, H. K., Grossman, S. R., McVean, G., Turnbaugh, P. J., Lander, E. S., Mitzenmacher, M., & Sabeti, P. C. (2011) · Science · doi:10.1126/science.1205438 · Cited by 3,339
Radiomics: the process and the challenges
Kumar, V., Gu, Y., Basu, S., Berglund, A., Eschrich, S. A., Schabath, M. B., Forster, K., Aerts, H. J. W. L., Dekker, A., Fenstermacher, D., et al. (2012) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2012.06.010 · Cited by 2,258
Texture analysis using gray level run lengths
Galloway, M. M. (1975) · Computer Graphics and Image Processing · doi:10.1016/s0146-664x(75)80008-6 · Cited by 2,141
Quantizing for minimum distortion
Max, J. (1960) · IEEE Transactions on Information Theory · doi:10.1109/tit.1960.1057548 · Cited by 2,038
Textural features corresponding to textural properties
Amadasun, M., & King, R. (1989) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/21.44046 · Cited by 1,148
CERR: A computational environment for radiotherapy research
Deasy, J. O., Blanco, A. I., & Clark, V. H. (2003) · Medical Physics · doi:10.1118/1.1568978 · Cited by 872
Permutation Methods: A Basis for Exact Inference
Ernst, M. D. (2004) · Statistical Science · doi:10.1214/088342304000000396 · Cited by 802
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Tixier, F., Le Rest, C. C., Hatt, M., Albarghach, N., Pradier, O., Metges, J.-P., Corcos, L., & Visvikis, D. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082404 · Cited by 696
Decoding global gene expression programs in liver cancer by noninvasive imaging
Segal, E., Sirlin, C. B., Ooi, C., Adler, A. S., Gollub, J., Chen, X., Chan, B. K., Matcuk, G. R., Barry, C. T., Chang, H. Y., et al. (2007) · Nature Biotechnology · doi:10.1038/nbt1306 · Cited by 629
Billingsley, K. G., Burt, M. E., Jara, E., Ginsberg, R. J., Woodruff, J. M., Leung, D. H. Y., & Brennan, M. F. (1999) · Annals of Surgery · doi:10.1097/00000658-199905000-00002 · Cited by 623
Collewet, G., Strzelecki, M., & Mariette, F. (2004) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2003.09.001 · Cited by 518
Exploring feature-based approaches in PET images for predicting cancer treatment outcomes
El Naqa, I., Grigsby, P. W., Apte, A., Kidd, E., Donnelly, E., Khullar, D., Chaudhari, S., Yang, D., Schmitt, M., Laforest, R., et al. (2009) · Pattern Recognition · doi:10.1016/j.patcog.2008.08.011 · Cited by 480
Self-citationUse of gray value distribution of run lengths for texture analysis
Chu, A., Sehgal, C. M., & Greenleaf, J. F. (1990) · Pattern Recognition Letters · doi:10.1016/0167-8655(90)90112-f · Cited by 464
Identification of noninvasive imaging surrogates for brain tumor gene-expression modules
Diehn, M., Nardini, C., Wang, D. S., McGovern, S., Jayaraman, M., Liang, Y., Aldape, K., Cha, S., & Kuo, M. D. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0801279105 · Cited by 440
Hatt, M., Majdoub, M., Vallières, M., Tixier, F., Le Rest, C. C., Groheux, D., Hindié, E., Martineau, A., Pradier, O., Hustinx, R., et al. (2015) · Journal of Nuclear Medicine · doi:10.2967/jnumed.114.144055 · Cited by 438
Self-citationPredicting outcomes in radiation oncology—multifactorial decision support systems
Lambin, P., van Stiphout, R. G. P. M., Starmans, M. H. W., Rios-Velazquez, E., Nalbantov, G., Aerts, H. J. W. L., Roelofs, E., van Elmpt, W., Boutros, P. C., Granone, P., et al. (2013) · Nature Reviews Clinical Oncology · doi:10.1038/nrclinonc.2012.196 · Cited by 402
Cook, G. J. R., Yip, C., Siddique, M., Goh, V., Chicklore, S., Roy, A., Marsden, P., Ahmad, S., & Landau, D. (2013) · Journal of Nuclear Medicine · doi:10.2967/jnumed.112.107375 · Cited by 394
Texture Indexes and Gray Level Size Zone Matrix Application to Cell Nuclei Classification
Thibault, G., Fertil, B., Navarro, C. L., Pereira, S., Cau, P., Lévy, N., Séqueira, J., & Mari, J.-L. (2009) · HAL · Cited by 374
Image characterizations based on joint gray level—run length distributions
Dasarathy, B. V., & Holder, E. B. (1991) · Pattern Recognition Letters · doi:10.1016/0167-8655(91)80014-2 · Cited by 304
Tumor Heterogeneity and Personalized Medicine
Longo, D. L. (2012) · New England Journal of Medicine · doi:10.1056/nejme1200656 · Cited by 246
Lewis, J. J., & Brennan, M. F. (1996) · Current Problems in Surgery · doi:10.1016/s0011-3840(96)80013-x · Cited by 241
Sarcoma tumor FDG uptake measured by PET and patient outcome: a retrospective analysis
Eary, J. F., O'Sullivan, F., Powitan, Y., Chandhury, K., Vernon, C., Bruckner, J. D., & Conrad, E. U. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-0859-5 · Cited by 213
Billingsley, K. G., Lewis, J. J., Leung, D. H. Y., Casper, E. S., Woodruff, J. M., & Brennan, M. F. (1999) · Cancer · doi:10.1002/(sici)1097-0142(19990115)85:2<389::aid-cncr17>3.0.co;2-j · Cited by 204
Combined PET/CT image characteristics for radiotherapy tumor response in lung cancer
Vaidya, M., Creach, K. M., Frye, J., Dehdashti, F., Bradley, J. D., & El Naqa, I. (2012) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2011.10.014 · Cited by 201
Self-citationSchwarzbach, M. H. M., Dimitrakopoulou-Strauss, A., Willeke, F., Hinz, U., Strauss, L. G., Zhang, Y.-M., Mechtersheimer, G., Attigah, N., Lehnert, T., & Herfarth, C. (2000) · Annals of Surgery · doi:10.1097/00000658-200003000-00011 · Cited by 189
van Velden, F. H. P., Cheebsumon, P., Yaqub, M., Smit, E. F., Hoekstra, O. S., Lammertsma, A. A., & Boellaard, R. (2011) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-011-1845-6 · Cited by 182
Classifier performance prediction for computer‐aided diagnosis using a limited dataset
Sahiner, B., Chan, H., & Hadjiiski, L. M. (2008) · Medical Physics · doi:10.1118/1.2868757 · Cited by 116
Naqa, I. E., Suneja, G., Lindsay, P. E., Hope, A. J., Alaly, J., Vićić, M., Bradley, J. D., Apte, A., & Deasy, J. O. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/22/001 · Cited by 102
Metastasis in Soft Tissue Sarcomas: Prognostic Criteria and Treatment Perspectives
Komdeur, R., Hoekstra, H. J., van den Berg, E., Molenaar, W. M., Pras, E., de Vries, E. G. E., & van der Graaf, W. T. A. (2002) · Cancer and Metastasis Reviews · doi:10.1023/a:1020893200768 · Cited by 60
Cited by
Zwanenburg, A., Vallières, M., Abdalah, M. A., Aerts, H. J. W. L., Andrearczyk, V., Apte, A., Ashrafinia, S., Bakas, S., Beukinga, R. J., Boellaard, R., et al. (2020) · Radiology · doi:10.1148/radiol.2020191145 · Cited by 4,177
“We defined a general radiomics image processing scheme based on descriptions in the literature (3,6,17,20).”
Self-citationBakas, S., Akbari, H., Sotiras, A., Bilello, M., Rozycki, M., Kirby, J. S., Freymann, J. B., Farahani, K., & Davatzikos, C. (2017) · Scientific Data · doi:10.1038/sdata.2017.117 · Cited by 3,049
Radiomics in medical imaging—“how-to” guide and critical reflection
van Timmeren, J. E., Cester, D., Tanadini-Lang, S., Alkadhi, H., & Baessler, B. (2020) · Insights into Imaging · doi:10.1186/s13244-020-00887-2 · Cited by 1,316
Applications and limitations of radiomics
Yip, S. S. F., & Aerts, H. J. W. L. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/13/r150 · Cited by 1,210
Machine and deep learning methods for radiomics
Avanzo, M., Wei, L., Stancanello, J., Vallières, M., Rao, A., Morin, O., Mattonen, S. A., & El Naqa, I. (2020) · Medical Physics · doi:10.1002/mp.13678 · Cited by 605
Self-citation
Metadata
- Authors
- Vallières, M., Freeman, C. R., Skamene, S. R., & El Naqa, I.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2015-06-29
- Volume
- 60
- Issue
- 14
- Pages
- 5471-5496
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2099698084
- Cited by
- 897
- References
- 36
- FWCI
- 46.56
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.