Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography
The DOI matches its Crossref record.
Abstract
Peripheral pulses have been recorded and analysed to determine the accuracy with which pulse transit times (PTTs) can be measured. Measurements of PTT between the ECG Q-wave and various peripheral sites were made in 10 normal subjects on 10 separate days. Mean values were determined for the ears (174 ms), fingers (245 ms), and toes (361 ms). The technique was sufficiently accurate to detect small changes in PTT due to changes in posture; sitting to lying, 5.2 ms. When comparing simultaneous measurements on bilateral sites only small differences in PTT were discovered, and these were not significant in the study group as a whole. However, these differences were significant in some individuals. When the subjects raised a single arm or leg, significant differences (38 ms and 49 ms respectively) were recorded between sides. The day-to-day repeatability sigma (expressed as the square root of the within-subject mean square variance) of individual PTT measurements on a subject (supine) was for ears, fingers and toes respectively 9.4, 9.2 and 12 ms. For right-left differences the repeatability was 7.2, 5.9 and 14 ms. Hence changes in PTTs, or differences between right and left sides, can be detected from single measurements with 95% confidence if they exceed approximately 20 ms in ears or fingers and 30 ms in toes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“An important study by Jago and Murray (1988) addressed the uncertainty in PPG measurements for a group of healthy adult subjects.”
BackgroundToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“spect to time [146], [148] have also been employed.”
BackgroundMethodLu, G., Yang, F., Taylor, J. A., & Stein, J. F. (2009) · Journal of Medical Engineering & Technology · doi:10.3109/03091900903150998 · Cited by 324
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Self-citationNon-constrained Blood Pressure Monitoring Using ECG and PPG for Personal Healthcare
Yoon, Y., Cho, J. H., & Yoon, G. (2009) · Journal of Medical Systems · doi:10.1007/s10916-008-9186-0 · Cited by 198
“In addition, there will be sex or age difference [16, 22].”
BackgroundResult
Metadata
- Authors
- Jago, J. R., & Murray, A.
- Venue
- Clinical Physics and Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1988-11
- Volume
- 9
- Issue
- 4
- Pages
- 319-329
- ISSN
- 0143-0815 (ISSN-L)
- OpenAlex
- W1979797421
- Cited by
- 74
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. https://app.cochat.ai/papers/10.1088/0143-0815/9/4/003
- The paper
- Jago, J. R., & Murray, A. (1988). Repeatability of peripheral pulse measurements on ears, fingers and toes using photoelectric plethysmography. Clinical Physics and Physiological Measurement. https://doi.org/10.1088/0143-0815/9/4/003
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.