Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Despite major advances in x-ray sources, detector arrays, gantry mechanical design and especially computer performance, one component of computed tomography (CT) scanners has remained virtually constant for the past 25 years-the reconstruction algorithm. Fundamental advances have been made in the solution of inverse problems, especially tomographic reconstruction, but these works have not been translated into clinical and related practice. The reasons are not obvious and seldom discussed. This review seeks to examine the reasons for this discrepancy and provides recommendations on how it can be resolved. We take the example of field of compressive sensing (CS), summarizing this new area of research from the eyes of practical medical physicists and explaining the disconnection between theoretical and application-oriented research. Using a few issues specific to CT, which engineers have addressed in very specific ways, we try to distill the mathematical problem underlying each of these issues with the hope of demonstrating that there are interesting mathematical problems of general importance that can result from in depth analysis of specific issues. We then sketch some unconventional CT-imaging designs that have the potential to impact on CT applications, if the link between applied mathematicians and engineers/physicists were stronger. Finally, we close with some observations on how the link could be strengthened. There is, we believe, an important opportunity to rapidly improve the performance of CT and related tomographic imaging techniques by addressing these issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 11×
“The RIP analysis is potentially useful for CT-system design; one could imagine designing a system with fixed numbers of measurements such that δ2s is minimized, where s is the expected sparsity of a typical signal.”
BackgroundMethodInfluentialStable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Cramming More Components onto Integrated Circuits (1965)
Moore, G. (2021) · Ideas That Created the Future · doi:10.7551/mitpress/12274.003.0027 · Cited by 6,241
Maximum likelihood estimation from incomplete data via the EM algorithm
Dempster, A. P. (1977) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 4,543
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
The Mathematics of Computerized Tomography
Natterer, F., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1429631 · Cited by 2,524
Cited by
Artificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803
Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT
Han, Y., & Ye, J. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823768 · Cited by 588
Advances in medical image analysis with vision Transformers: A comprehensive review
Azad, R., Kazerouni, A., Heidari, M., Aghdam, E. K., Molaei, A., Jia, Y., Jose, A., Roy, R., & Merhof, D. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103000 · Cited by 485
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Tensor-Based Formulation and Nuclear Norm Regularization for Multienergy Computed Tomography
Semerci, O., Hao, N., Kilmer, M. E., & Miller, E. L. (2014) · IEEE Transactions on Image Processing · doi:10.1109/tip.2014.2305840 · Cited by 389
CNN-Based Projected Gradient Descent for Consistent CT Image Reconstruction
Gupta, H., Jin, K. H., Nguyen, H. Q., McCann, M. T., & Unser, M. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2832656 · Cited by 380
Evaluation of sparse-view reconstruction from flat-panel-detector cone-beam CT
Bian, J., Siewerdsen, J. H., Han, X., Sidky, E. Y., Prince, J. L., Pelizzari, C. A., & Pan, X. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/22/001 · Cited by 373
Self-citationTIGRE: a MATLAB-GPU toolbox for CBCT image reconstruction
Biguri, A., Dosanjh, M., Hancock, S., & Soleimani, M. (2016) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/2/5/055010 · Cited by 370
Compressed-Sensing MRI With Random Encoding
Haldar, J. P., Hernando, D., & Liang, Z.-P. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2085084 · Cited by 308
Compressed sensing electron tomography
Leary, R., Saghi, Z., Midgley, P. A., & Holland, D. J. (2013) · Ultramicroscopy · doi:10.1016/j.ultramic.2013.03.019 · Cited by 281
Successes and challenges in non-destructive testing of aircraft composite structures
TOWSYFYAN, H., BIGURI, A., BOARDMAN, R., & BLUMENSATH, T. (2020) · Chinese Journal of Aeronautics · doi:10.1016/j.cja.2019.09.017 · Cited by 272
Willemink, M. J., Leiner, T., de Jong, P. A., de Heer, L. M., Nievelstein, R. A. J., Schilham, A. M. R., & Budde, R. P. J. (2013) · European Radiology · doi:10.1007/s00330-012-2764-z · Cited by 268
Compressed sensing based cone‐beam computed tomography reconstruction with a first‐order methoda)
Choi, K., Wang, J., Zhu, L., Suh, T., Boyd, S., & Xing, L. (2010) · Medical Physics · doi:10.1118/1.3481510 · Cited by 255
Laser absorption spectroscopy for combustion diagnosis in reactive flows: A review
Liu, C., & Xu, L. (2019) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2018.1448854 · Cited by 230
“T he fi ltered back-projection (FBP) algorithm that is commonly used based on the analytical solution of the Radon transform (138).”
MethodModelling the physics in the iterative reconstruction for transmission computed tomography
Nuyts, J., De Man, B., Fessler, J. A., Zbijewski, W., & Beekman, F. J. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/12/r63 · Cited by 199
“The very fact that the object is discretized into a finite number of basis functions inherently leads to discrepancies between the measured projection data and the simulated re-projections estimated during the reconstruction (Zbijewski and Beekman 2004a, Pan et al 2009, Herman and Davidi 2008).”
BackgroundInvestigation of iterative image reconstruction in three-dimensional optoacoustic tomography
Wang, K., Su, R., Oraevsky, A. A., & Anastasio, M. A. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/17/5399 · Cited by 191
An Introduction to Sparse Stochastic Processes
Unser, M., & Tafti, P. D. (2014) · Cambridge University Press eBooks · doi:10.1017/cbo9781107415805 · Cited by 184
Compressive sensing in medical imaging
Graff, C. G., & Sidky, E. Y. (2015) · Applied Optics · doi:10.1364/ao.54.000c23 · Cited by 184
“Even though the goal of this model is to obtain a CSG, much work has been performed in adapting this constrained TV-minimization model to x-ray CT [54-60].”
MethodSelf-citationRobust principal component analysis-based four-dimensional computed tomography
Gao, H., Cai, J.-F., Shen, Z., & Zhao, H. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/11/002 · Cited by 181
“Tremendous effort has been devoted to dose reduction (Xing et al 2006, Jiang et al 2008, Pan et al 2009, Fahimian et al 2010, Wang et al 2010).”
BackgroundIn vivo small animal imaging: Current status and future prospects
Kagadis, G. C., Loudos, G., Katsanos, K., Langer, S. G., & Nikiforidis, G. C. (2010) · Medical Physics · doi:10.1118/1.3515456 · Cited by 164
Basics of iterative reconstruction methods in computed tomography: A vendor-independent overview
Stiller, W. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.10.025 · Cited by 160
Metadata
- Authors
- Pan, X., Sidky, E. Y., & Vannier, M.
- Venue
- Inverse Problems
- Publisher
- IOP Publishing
- Published
- 2009-12-01
- Volume
- 25
- Issue
- 12
- Pages
- 123009
- ISSN
- 0266-5611 (ISSN-L)
- 1361-6420
- OpenAlex
- W2071847032
- Cited by
- 572
- References
- 53
- FWCI
- 18.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.