Why do commercial CT scanners still employ traditional, filtered back-projection for image reconstruction?
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Despite major advances in x-ray sources, detector arrays, gantry mechanical design and especially computer performance, one component of computed tomography (CT) scanners has remained virtually constant for the past 25 years-the reconstruction algorithm. Fundamental advances have been made in the solution of inverse problems, especially tomographic reconstruction, but these works have not been translated into clinical and related practice. The reasons are not obvious and seldom discussed. This review seeks to examine the reasons for this discrepancy and provides recommendations on how it can be resolved. We take the example of field of compressive sensing (CS), summarizing this new area of research from the eyes of practical medical physicists and explaining the disconnection between theoretical and application-oriented research. Using a few issues specific to CT, which engineers have addressed in very specific ways, we try to distill the mathematical problem underlying each of these issues with the hope of demonstrating that there are interesting mathematical problems of general importance that can result from in depth analysis of specific issues. We then sketch some unconventional CT-imaging designs that have the potential to impact on CT applications, if the link between applied mathematicians and engineers/physicists were stronger. Finally, we close with some observations on how the link could be strengthened. There is, we believe, an important opportunity to rapidly improve the performance of CT and related tomographic imaging techniques by addressing these issues.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Maximum Likelihood from Incomplete Data Via the EM Algorithm
Dempster, A. P., Laird, N. M., & Rubin, D. B. (1977) · Journal of the Royal Statistical Society Series B: Statistical Methodology · doi:10.1111/j.2517-6161.1977.tb01600.x · Cited by 50,444
Candes, E. J., Romberg, J., & Tao, T. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2005.862083 · Cited by 15,639
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017 · cited 11×
“The RIP analysis is potentially useful for CT-system design; one could imagine designing a system with fixed numbers of measurements such that δ2s is minimized, where s is the expected sparsity of a typical signal.”
BackgroundMethodInfluentialStable signal recovery from incomplete and inaccurate measurements
Candès, E. J., Romberg, J. K., & Tao, T. (2006) · Communications on Pure and Applied Mathematics · doi:10.1002/cpa.20124 · Cited by 7,036
Sparse MRI: The application of compressed sensing for rapid MR imaging
Lustig, M., Donoho, D., & Pauly, J. M. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21391 · Cited by 6,952
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Cramming More Components onto Integrated Circuits (1965)
Moore, G. (2021) · Ideas That Created the Future · doi:10.7551/mitpress/12274.003.0027 · Cited by 6,241
Maximum likelihood estimation from incomplete data via the EM algorithm
Dempster, A. P. (1977) · Journal of the Royal Statistical Society Series A (Statistics in Society) · Cited by 4,543
Gordon, R., Bender, R., & Herman, G. T. (1970) · Journal of Theoretical Biology · doi:10.1016/0022-5193(70)90109-8 · Cited by 2,791
The Mathematics of Computerized Tomography
Natterer, F., & Wang, G. (2002) · Medical Physics · doi:10.1118/1.1429631 · Cited by 2,524
Iterative hard thresholding for compressed sensing
Blumensath, T., & Davies, M. E. (2009) · Applied and Computational Harmonic Analysis · doi:10.1016/j.acha.2009.04.002 · Cited by 2,275
Sparsity and incoherence in compressive sampling
Candès, E., & Romberg, J. (2007) · Inverse Problems · doi:10.1088/0266-5611/23/3/008 · Cited by 2,075
Sidky, E. Y., & Pan, X. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/17/021 · Cited by 1,995
Self-citationEM reconstruction algorithms for emission and transmission tomography.
Lange, K. L., & Carson, R. E. (1984) · PubMed · Cited by 1,769
The Mathematics of Computerized Tomography
Natterer, F. (1986) · Vieweg+Teubner eBooks · doi:10.1007/978-3-663-01409-6 · Cited by 1,768
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Exact Reconstruction of Sparse Signals via Nonconvex Minimization
Chartrand, R. (2007) · IEEE Signal Processing Letters · doi:10.1109/lsp.2007.898300 · Cited by 1,277 · cited 1×
“We have adapted constrained, TV-minimization to CT [62,63] and exploited non-convex optimization [64] to digital breast tomosynthesis [65,66].”
MethodChen, G.-H., Tang, J., & Leng, S. (2008) · Medical Physics · doi:10.1118/1.2836423 · Cited by 1,141
Accurate image reconstruction from few-views and limited-angle data in divergent-beam CT
Sidky, E. Y., Kao, C.-M., & Pan, X. (2006) · Journal of X-Ray Science and Technology: Clinical Applications of Diagnosis and Therapeutics · doi:10.3233/xst-2006-00155 · Cited by 1,091
Self-citationBarrett, H. H., Myers, K. J., & Rathee, S. (2004) · Medical Physics · doi:10.1118/1.1677252 · Cited by 1,065
Space-alternating generalized expectation-maximization algorithm
Fessler, J. A., & Hero, A. O. (1994) · IEEE Transactions on Signal Processing · doi:10.1109/78.324732 · Cited by 1,063
Image Restoration by the Method of Convex Projections: Part 1ߞTheory
Youla, D. C., & Webb, H. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307555 · Cited by 1,021
Parallel optimization: Theory, algorithms, and applications
(1998) · Computers & Mathematics with Applications · doi:10.1016/s0898-1221(98)90713-1 · Cited by 813
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Kalender, W. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r03 · Cited by 689
Ordered subsets algorithms for transmission tomography
Erdogan, H., & Fessler, J. A. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/11/311 · Cited by 556
Optimal short scan convolution reconstruction for fan beam CT
Parker, D. L. (1982) · Medical Physics · doi:10.1118/1.595078 · Cited by 525
Highly Undersampled Magnetic Resonance Image Reconstruction via Homotopic $\ell_{0}$-Minimization
Trzasko, J., & Manduca, A. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.927346 · Cited by 490
Distance-driven projection and backprojection in three dimensions
Man, B. D., & Basu, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/11/024 · Cited by 459
Iterative reconstruction techniques in emission computed tomography
Qi, J., & Leahy, R. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/15/r01 · Cited by 415
X‐ray scatter correction algorithm for cone beam CT imaging
Ning, R., Tang, X., & Conover, D. (2004) · Medical Physics · doi:10.1118/1.1711475 · Cited by 322
Fast algorithms for nonconvex compressive sensing: MRI reconstruction from very few data
Chartrand, R. (2009) · 2009 IEEE International Symposium on Biomedical Imaging: From Nano to Macro · doi:10.1109/isbi.2009.5193034 · Cited by 312
Delaney, A. H., & Bresler, Y. (1998) · IEEE Transactions on Image Processing · doi:10.1109/83.660997 · Cited by 304
The RADON TRANSFORM and LOCAL TOMOGRAPHY
Ramm, A. G., & Katsevich, A. I. (2020) · CRC Press eBooks · doi:10.1201/9781003069331 · Cited by 301
Handbook of Medical Imaging, Volume 1. Physics and Psychophysics
(2000) · SPIE eBooks · doi:10.1117/3.832716 · Cited by 227
Real-time 3D computed tomographic reconstruction using commodity graphics hardware
Xu, F., & Mueller, K. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/006 · Cited by 223
Cone-Beam Reconstruction Using Filtered Backprojection
Turbell, H. (2001) · Cited by 199
Sparseness prior based iterative image reconstruction for retrospectively gated cardiac micro‐CT
Song, J., Liu, Q. H., Johnson, G. A., & Badea, C. T. (2007) · Medical Physics · doi:10.1118/1.2795830 · Cited by 183
The ultrahyperbolic differential equation with four independent variables
John, F. (1938) · Duke Mathematical Journal · doi:10.1215/s0012-7094-38-00423-5 · Cited by 181
Sidky, E. Y., Pan, X., Reiser, I. S., Nishikawa, R. M., Moore, R. H., & Kopans, D. B. (2009) · Medical Physics · doi:10.1118/1.3232211 · Cited by 181
Self-citationAccurate image reconstruction from few-view and limited-angle data in diffraction tomography
LaRoque, S. J., Sidky, E. Y., & Pan, X. (2008) · Journal of the Optical Society of America A · doi:10.1364/josaa.25.001772 · Cited by 156
Self-citationLi, M., Yang, H., & Kudo, H. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/15/303 · Cited by 132
Image covariance and lesion detectability in direct fan-beam x-ray computed tomography
Wunderlich, A., & Noo, F. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/10/002 · Cited by 113
Material Separation with Dual-Layer CT
Carmi, R., Naveh, G., & Altman, A. (2006) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.2005.1596697 · Cited by 110
Zhuang, T., Leng, S., Nett, B. E., et al. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/24/007 · Cited by 108
Hyperfast parallel‐beam and cone‐beam backprojection using the cell general purpose hardware
Kachelrieß, M., Knaup, M., & Bockenbach, O. (2007) · Medical Physics · doi:10.1118/1.2710328 · Cited by 96
Image reconstruction in peripheral and central regions‐of‐interest and data redundancy
Pan, X., Zou, Y. S., & Xia, D. (2005) · Medical Physics · doi:10.1118/1.1844171 · Cited by 82
Self-citationCharacterization and suppression of edge and aliasing artefacts in iterative x-ray CT reconstruction
Zbijewski, W. B., & Beekman, F. J. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/010 · Cited by 56
Recent developments in wide-detector cardiac computed tomography
Choi, S. I., George, R. T., Schuleri, K. H., Chun, E. J., Lima, J. A. C., & Lardo, A. C. (2009) · International journal of cardiac imaging · doi:10.1007/s10554-009-9443-4 · Cited by 55
On Theory of Compressive Sensing via L_1-Minimization: Simple Derivations and Extensions
Zhang, Y. (2008) · Rice Research Repository (Rice University) · Cited by 42
Consistency conditions upon 3D CT data and the wave equation
Patch, S. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/15/306 · Cited by 42
Sidky, E. Y., Reiser, I., Nishikawa, R. M., Pan, X., Chartrand, R., Kopans, D. B., & Moore, R. H. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.772796 · Cited by 28
Self-citation
Cited by
Artificial intelligence in radiology
Hosny, A., Parmar, C., Quackenbush, J., Schwartz, L. H., & Aerts, H. J. W. L. (2018) · Nature Reviews Cancer · doi:10.1038/s41568-018-0016-5 · Cited by 3,803
Framing U-Net via Deep Convolutional Framelets: Application to Sparse-View CT
Han, Y., & Ye, J. C. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823768 · Cited by 588
Advances in medical image analysis with vision Transformers: A comprehensive review
Azad, R., Kazerouni, A., Heidari, M., Aghdam, E. K., Molaei, A., Jia, Y., Jose, A., Roy, R., & Merhof, D. (2024) · Medical Image Analysis · doi:10.1016/j.media.2023.103000 · Cited by 485
Iterative reconstruction techniques for computed tomography Part 1: Technical principles
Willemink, M. J., de Jong, P. A., Leiner, T., de Heer, L. M., Nievelstein, R. A. J., Budde, R. P. J., & Schilham, A. M. R. (2013) · European Radiology · doi:10.1007/s00330-012-2765-y · Cited by 443
Medical image processing on the GPU – Past, present and future
Eklund, A., Dufort, P., Forsberg, D., & LaConte, S. M. (2013) · Medical Image Analysis · doi:10.1016/j.media.2013.05.008 · Cited by 397
Metadata
- Authors
- Pan, X., Sidky, E. Y., & Vannier, M.
- Venue
- Inverse Problems
- Publisher
- IOP Publishing
- Published
- 2009-12-01
- Volume
- 25
- Issue
- 12
- Pages
- 123009
- ISSN
- 0266-5611 (ISSN-L)
- 1361-6420
- OpenAlex
- W2071847032
- Cited by
- 572
- References
- 53
- FWCI
- 18.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.