Reference liquids for the calibration of dielectric sensors and measurement instruments
The DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
A comparative study of microwave complex dielectric permittivity data from different laboratories is provided for liquids. Four liquids - water, cyclohexane, methanol and dimethyl sulphoxide - are recommended as reference materials because their parameter sets from different measurements result in almost identical predictions of their dielectric properties in the frequency range up to 10 GHz. Within the limits of experimental error this agreement includes that of the extrapolated low frequency permittivity with the recently determined static permittivity of the liquids. Parameters for water are given for the frequency range 0 - 60 degrees C. For cyclohexane, which does not display relaxation behaviour up to the submillimetre frequency range, the frequency-independent permittivity is represented between 10 and 50 degrees C. Relaxation and static permittivity data for methanol and dimethyl sulphoxide are presented at 25 degrees C.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dispersion and Absorption in Dielectrics I. Alternating Current Characteristics
Cole, K. S., & Cole, R. H. (1941) · The Journal of Chemical Physics · doi:10.1063/1.1750906 · Cited by 10,152
(1979) · Elsevier eBooks · doi:10.1016/b978-0-12-147701-1.x5001-5 · Cited by 1,784
Speedy, R. J., & Angell, C. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.433153 · Cited by 926
Complex permittivity of water as a function of frequency and temperature
Kaatze, U. (1989) · Journal of Chemical & Engineering Data · doi:10.1021/je00058a001 · Cited by 905
Self-citationDielectric constant of water from 0 to 100 C
Malmberg, C., & Maryott, A. A. (1956) · Journal of research of the National Bureau of Standards · doi:10.6028/jres.056.001 · Cited by 851
Kindt, J. T., & Schmuttenmaer, C. A. (1996) · The Journal of Physical Chemistry · doi:10.1021/jp960141g · Cited by 687
Broadband Complex Refractive Indices of Ice and Water
Ray, P. S. (1972) · Applied Optics · doi:10.1364/ao.11.001836 · Cited by 601 · cited 1×
“It is only mentioned that interpolation formulae for the extrapolated high frequency permittivity and the relaxation time of water have been presented for various temperature and frequency ranges [4, 5, 65], some of them derived for a description of the complex permittivity data by a Cole–Cole [66] instead of a Debye…”
Ro/nne, C., Thrane, L., Åstrand, P.-O., Wallqvist, A., Mikkelsen, K. V., & Keiding, S. R. (1997) · The Journal of Chemical Physics · doi:10.1063/1.474242 · Cited by 587 · cited 1×
“[43, 90, 103] and methanol [90], at such high frequencies,”
Dielectric spectra of some common solvents in the microwave region. Water and lower alcohols
Barthel, J., Bachhuber, K., Buchner, R., & Hetzenauer, H. (1990) · Chemical Physics Letters · doi:10.1016/0009-2614(90)87204-5 · Cited by 512
THz Spectroscopy of LiquidH2OandD2O
Rønne, C., Åstrand, P.-O., & Keiding, S. R. (1999) · Physical Review Letters · doi:10.1103/physrevlett.82.2888 · Cited by 366
Ellison, W. J., Lamkaouchi, K., & Moreau, J.-M. (1996) · Journal of Molecular Liquids · doi:10.1016/0167-7322(96)00926-9 · Cited by 312 · cited 9×
“T (◦C) [4] [5, 34] [35] [53] [54] [55] [56] [58] [26] ε̄s 0 87.”
InfluentialTHE DIELECTRIC CONSTANT OF WATER AS A FUNCTION OF TEMPERATURE AND PRESSURE1,2
Owen, B. B., Miller, R. C., Milner, C. E., & Cogan, H. L. (1961) · The Journal of Physical Chemistry · doi:10.1021/j100828a035 · Cited by 249 · cited 1×
“T (◦C) [4] [5, 34] [35] [53] [54] [55] [56] [58] [26] ε̄s 0 87.”
High frequency permittivity and its use in the investigation of solution properties
Barthel, J. M. G., & Buchner, R. (1991) · Pure and Applied Chemistry · doi:10.1351/pac199163101473 · Cited by 223 · cited 2×
“The dielectric spectrum of methanol has been alternatively discussed, including the use of three Debye relaxation terms to describe the data at frequencies up to 293 GHz [89, 90].”
The dielectric relaxation time of supercooled water
Bertolini, D., Cassettari, M., & Salvetti, G. (1982) · The Journal of Chemical Physics · doi:10.1063/1.443323 · Cited by 203 · cited 1×
“Static permittivities of water at low temperatures: [60]; • [61]; [62]; [63]; [64]; ◦, ε̄s (table 5); dotted line, relation (8) with parameters from [5]; full line, equation (8) with parameters given in the text.”
Dielectric spectrum of dimethyl sulfoxide/water mixtures as a function of composition
Kaatze, U., Pottel, R., & Schaefer, M. (1989) · The Journal of Physical Chemistry · doi:10.1021/j100351a057 · Cited by 200 · cited 2×
“The spectra from this laboratory [97, 99] used for the extrapolation, however, included complex permittivities which had been obtained with methods utilizing reference Figure 10.”
Self-citationMeasurements of the optical constants of liquid H_2O and D_2O between 6 and 450 cm^−1
Afsar, M. N., & Hasted, J. B. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.000902 · Cited by 194
Hydrogen network fluctuations and dielectric spectrometry of liquids
Kaatze, U., Behrends, R., & Pottel, R. (2002) · Journal of Non-Crystalline Solids · doi:10.1016/s0022-3093(02)01084-0 · Cited by 187 · cited 1×
“[43, 90, 103] and methanol [90], at such high frequencies,”
Self-citationBroadband dielectric spectrometry of liquids and biosystems
Kaatze, U., & Feldman, Y. (2006) · Measurement Science and Technology · doi:10.1088/0957-0233/17/2/r01 · Cited by 174
Self-citationBarthel, J., Bachhuber, K., Buchner, R., Gill, J. B., & Kleebauer, M. (1990) · Chemical Physics Letters · doi:10.1016/0009-2614(90)85071-j · Cited by 162
High Frequency Dispersion in n-Propanol
Cole, R. H., & Davidson, D. W. (1952) · The Journal of Chemical Physics · doi:10.1063/1.1700767 · Cited by 133
The dielectric constant of water and heavy water between 0 and 40.degree.
Vidulich, G. A., Evans, D. F., & Kay, R. L. (1967) · The Journal of Physical Chemistry · doi:10.1021/j100862a028 · Cited by 130 · cited 1×
“T (◦C) [4] [5, 34] [35] [53] [54] [55] [56] [58] [26] ε̄s 0 87.”
Gregory, A. P., & Clarke, R. N. (2005) · Measurement Science and Technology · doi:10.1088/0957-0233/16/7/013 · Cited by 127
W.J.T. (1972) · Journal of Molecular Structure · doi:10.1016/0022-2860(72)85198-6 · Cited by 99
Khirade, P. W., Chaudhari, A., Shinde, J. B., Helambe, S. N., & Mehrotra, S. C. (1999) · Journal of Chemical & Engineering Data · doi:10.1021/je980118j · Cited by 70
The temperature variation of the near millimetre wavelength optical constants of water
Hasted, J. B., Husain, S., Frescura, F. A. M., & Birch, J. R. (1987) · Infrared Physics · doi:10.1016/0020-0891(87)90044-3 · Cited by 70
Langhe, P. D., Martens, L., & Zutter, D. D. (1994) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/19.368062 · Cited by 66
Entropy reduction by motional sideband excitation
DEHMELT, H. G. (1976) · Nature · doi:10.1038/262777a0 · Cited by 64
Folgerø, K., Friisø, T., Hilland, J., & Tjomsland, T. (1995) · Measurement Science and Technology · doi:10.1088/0957-0233/6/7/022 · Cited by 60
New techniques for dispersive Fourier transform spectrometry of liquids
Afsar, M. N., Hasted, J. B., & Chamberlain, J. (1976) · Infrared Physics · doi:10.1016/0020-0891(76)90051-8 · Cited by 58
Pressure and temperature dependence of the electrical permittivities of formamide and water
Dunn, L. A., & Stokes, R. H. (1969) · Transactions of the Faraday Society · doi:10.1039/tf9696502906 · Cited by 54 · cited 2×
“IUPAC recommended [56] and previous NBS [69] data.”
Submillimetre Wave Dielectric Dispersion in Water
Zafar, M., Hasted, J. B., & Chamberlain, J. M. (1973) · Nature Physical Science · doi:10.1038/physci243106a0 · Cited by 53
Measurement of Complex Permittivity of Liquids at Frequencies from 5 to 40 GHz
Loon, R. V., & Finsy, R. (1973) · Review of Scientific Instruments · doi:10.1063/1.1686354 · Cited by 42
Simple sensor system for measuring the dielectric properties of saline solutions
Hilland, J. (1997) · Measurement Science and Technology · doi:10.1088/0957-0233/8/8/011 · Cited by 41
Temperature variation of the near millimetre wavelength optical constants of PMMA
Mény, C., Léotin, J., Dugas, J., & Birch, J. R. (1991) · Infrared Physics · doi:10.1016/0020-0891(91)90029-f · Cited by 30
Efficient and accurate full-wave analysis of the open-ended coaxial cable
Panariello, G., Verolino, L., & Vitolo, G. (2001) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.932251 · Cited by 26
Hydrogen Network Fluctuations and the Microwave Dielectric Properties of Liquid Water
Kaatze, U. (2000) · Subsurface Sensing Technologies and Applications · doi:10.1023/a:1026559430935 · Cited by 24
Self-citation
Cited by
Interactions and dynamics in electrolyte solutions by dielectric spectroscopy
Buchner, R., & Hefter, G. (2009) · Physical Chemistry Chemical Physics · doi:10.1039/b906555p · Cited by 318
The mechanism of the dielectric relaxation in water
Popov, I., Ishai, P. B., Khamzin, A., & Feldman, Y. (2016) · Physical Chemistry Chemical Physics · doi:10.1039/c6cp02195f · Cited by 179
Juan, C. G., Bronchalo, E., Potelon, B., Quendo, C., Avila-Navarro, E., & Sabater-Navarro, J. M. (2019) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2018.2866743 · Cited by 177
Metadata
- Authors
- Kaatze, U.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 2007-02-27
- Volume
- 18
- Issue
- 4
- Pages
- 967-976
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2078049308
- Cited by
- 162
- References
- 36
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.