Dynamic ranges of velocity and spatial resolution of particle image velocimetry
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
To observe instantaneous fields of vorticity and rate-of-strain using PIV (particle image velocimetry) measurements of the velocity field, it is necessary to achieve maximum dynamic ranges in space and in velocity while simultaneously making accurate, low-noise measurements for the differentiation process. In this paper the dynamic ranges achievable with PIV are established in the context of the super-resolution algorithm described previously which seeks to extract the maximum possible information from a particle image field. Bounds on the dynamic spatial range and the dynamic velocity range are established in terms of optical parameters, and simple rules are derived for optimum design of PIV optical systems for various types of image recording media.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Particle-Imaging Techniques for Experimental Fluid Mechanics
Adrian, R. J. (1991) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fl.23.010191.001401 · Cited by 3,405
Self-citationEffect of resolution on the speed and accuracy of particle image velocimetry interrogation
Prasad, A. K., Adrian, R. J., Landreth, C. C., & Offutt, P. W. (1992) · Experiments in Fluids · doi:10.1007/bf00218156 · Cited by 493
Self-citationDigital particle image velocimetry: theory and application
Westerweel, J. (1993) · Research Repository (Delft University of Technology) · Cited by 415
Super-resolution particle imaging velocimetry
Keane, R. D., Adrian, R. J., & Zhang, Y. (1995) · Measurement Science and Technology · doi:10.1088/0957-0233/6/6/013 · Cited by 251
Self-citationStatistical investigation of errors in particle image velocimetry
GUEZENNEC, Y. G., & Kiritsis, N. (1990) · Experiments in Fluids · doi:10.1007/bf00215022 · Cited by 49
Cited by
Shake-The-Box: Lagrangian particle tracking at high particle image densities
Schanz, D., Gesemann, S., & Schröder, A. (2016) · Experiments in Fluids · doi:10.1007/s00348-016-2157-1 · Cited by 717
Spanwise structure and scale growth in turbulent boundary layers
TOMKINS, C. D., & ADRIAN, R. J. (2003) · Journal of Fluid Mechanics · doi:10.1017/s0022112003005251 · Cited by 599
Self-citationParticle Image Velocimetry for Complex and Turbulent Flows
Westerweel, J., Elsinga, G. E., & Adrian, R. J. (2013) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-120710-101204 · Cited by 557
Self-citationCierpka, C., & Kähler, C. J. (2012) · Journal of Visualization · doi:10.1007/s12650-011-0107-9 · Cited by 450
On the uncertainty of digital PIV and PTV near walls
Kähler, C. J., Scharnowski, S., & Cierpka, C. (2012) · Experiments in Fluids · doi:10.1007/s00348-012-1307-3 · Cited by 294
PIV uncertainty quantification by image matching
Sciacchitano, A., Wieneke, B., & Scarano, F. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/4/045302 · Cited by 286
Uncertainty quantification in particle image velocimetry
Sciacchitano, A. (2019) · Measurement Science and Technology · doi:10.1088/1361-6501/ab1db8 · Cited by 268
Collaborative framework for PIV uncertainty quantification: comparative assessment of methods
Sciacchitano, A., Neal, D. R., Smith, B. L., Warner, S. O., Vlachos, P. P., Wieneke, B., & Scarano, F. (2015) · Measurement Science and Technology · doi:10.1088/0957-0233/26/7/074004 · Cited by 244
PIV optimization for the study of turbulent flow using spectral analysis
Foucaut, J. M., Carlier, J., & Stanislas, M. (2004) · Measurement Science and Technology · doi:10.1088/0957-0233/15/6/003 · Cited by 205
“In this configuration, the Airy disk diameter is of the order of 12 µm which gives a size of the order of 1.5 pixel (Adrian(1997)).”
InfluentialLandslide generated impulse waves.
Fritz, H. M., Hager, W. H., & Minor, H.-E. (2003) · Experiments in Fluids · doi:10.1007/s00348-003-0659-0 · Cited by 197
3D Lagrangian Particle Tracking in Fluid Mechanics
Schröder, A., & Schanz, D. (2023) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-031822-041721 · Cited by 180
Time-resolved reconstruction of the full velocity field around a dynamically-scaled flapping wing
Poelma, C., Dickson, W. B., & Dickinson, M. H. (2006) · Experiments in Fluids · doi:10.1007/s00348-006-0172-3 · Cited by 176
“Furthermore, the curvature of the focal plane was small compared to the depth-offield [which was estimated at approximately 3.8 cm for f/ 5.6 and a magnification factor M of 0.044 (Adrian 1997)], so that the entire image was in focus.”
BackgroundInfluentialExperimental investigation of Rayleigh–Taylor mixing at small Atwood numbers
RAMAPRABHU, P., & ANDREWS, M. J. (2004) · Journal of Fluid Mechanics · doi:10.1017/s0022112003007419 · Cited by 169
“Following the method of Adrian (1997), we determined the error in our velocity measurements to be ∼ ± 0.05 cm s−1 based on the uncertainty associated with the location of a particle.”
MethodInfluentialParticle image velocimetry - Classical operating rules from today’s perspective
Scharnowski, S., & Kähler, C. J. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106185 · Cited by 166
Metadata
- Authors
- Adrian, R. J.
- Venue
- Measurement Science and Technology
- Publisher
- IOP Publishing
- Published
- 1997-12-01
- Volume
- 8
- Issue
- 12
- Pages
- 1393-1398
- ISSN
- 0957-0233 (ISSN-L)
- 1361-6501
- OpenAlex
- W2004761778
- Cited by
- 328
- References
- 5
- FWCI
- 5.34
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.