Pt–Pb alloy nanoparticle/carbon nanotube nanocomposite: a strong electrocatalyst for glucose oxidation
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
A Pt–Pb alloy nanoparticle/multi-walled carbon nanotube (Pt–Pb/MWCNT) nanocomposite was prepared by electrodepositing Pt–Pb alloy onto MWCNTs that were vertically aligned on Ta plates. The 10–40 nm diameter Pt–Pb alloy nanoparticles were mainly deposited at the tips, and sparsely dispersed on the sidewalls of the bamboo-like MWCNTs, as demonstrated by scanning electron microscopy, transmission electron microscopy (TEM), and x-ray diffraction. The high resolution TEM (HRTEM) image showed a snowflake-like morphology for the Pt–Pb nanoparticles. This Pt–Pb/MWCNT nanocomposite exhibited much stronger electrocatalytic activity toward glucose oxidation than pristine MWCNTs, Pt–Pb on glassy carbon, and Pt/MWCNT and Au/MWCNT nanocomposites, in both neutral and alkaline solutions. This Pt–Pb/MWCNT nanocomposite electrode is hence promising for development as a nonenzymatic glucose sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Helical microtubules of graphitic carbon
Iijima, S. (1991) · Nature · doi:10.1038/354056a0 · Cited by 43,098
Ajayan, P. M. (1999) · Chemical Reviews · doi:10.1021/cr970102g · Cited by 3,151
Electronic structure of atomically resolved carbon nanotubes
Wilder, J. W. G., Venema, L. C., Rinzler, A. G., Smalley, R. E., & Dekker, C. (1998) · Nature · doi:10.1038/34139 · Cited by 3,061
Atomic structure and electronic properties of single-walled carbon nanotubes
Odom, T. W., Huang, J.-L., Kim, P., & Lieber, C. M. (1998) · Nature · doi:10.1038/34145 · Cited by 2,500
Carbon nanotubule membranes for electrochemical energy storage and production
Che, G., Lakshmi, B. B., Fisher, E. R., & Martin, C. R. (1998) · Nature · doi:10.1038/30694 · Cited by 1,767
Carbon nanotube electrode for oxidation of dopamine
Britto, P. J., Santhanam, K. S. V., & Ajayan, P. M. (1996) · Bioelectrochemistry and Bioenergetics · doi:10.1016/0302-4598(96)05078-7 · Cited by 885
Luo, H., Shi, Z., Li, N., Gu, Z., & Zhuang, Q. (2001) · Analytical Chemistry · doi:10.1021/ac000967l · Cited by 829
Nonenzymatic Glucose Detection Using Mesoporous Platinum
Park, S., Chung, T. D., & Kim, H. C. (2003) · Analytical Chemistry · doi:10.1021/ac0263465 · Cited by 594
Improved Charge Transfer at Carbon Nanotube Electrodes
Britto, P. J., Santhanam, K. S. V., Rubio, A., Alonso, J. A., & Ajayan, P. M. (1999) · Advanced Materials · doi:10.1002/(sici)1521-4095(199902)11:2<154::aid-adma154>3.0.co;2-b · Cited by 515
Kinetics and mechanism of glucose electrooxidation on different electrode-catalysts
Vassilyev, Y. B., Khazova, O. A., & Nikolaeva, N. N. (1985) · Journal of Electroanalytical Chemistry and Interfacial Electrochemistry · doi:10.1016/0022-0728(85)85084-1 · Cited by 422
Cited by
Nitrogen-Doped Carbon Nanotube Arrays with High Electrocatalytic Activity for Oxygen Reduction
Gong, K., Du, F., Xia, Z., Durstock, M., & Dai, L. (2009) · Science · doi:10.1126/science.1168049 · Cited by 7,188
Nitrogen-Doped Graphene as Efficient Metal-Free Electrocatalyst for Oxygen Reduction in Fuel Cells
Qu, L., Liu, Y., Baek, J.-B., & Dai, L. (2010) · ACS Nano · doi:10.1021/nn901850u · Cited by 3,948
Metal-Free Catalysts for Oxygen Reduction Reaction
Dai, L., Xue, Y., Qu, L., Choi, H.-J., & Baek, J.-B. (2015) · Chemical Reviews · doi:10.1021/cr5003563 · Cited by 2,380
Carbon Nanomaterials for Advanced Energy Conversion and Storage
Dai, L., Chang, D. W., Baek, J., & Lu, W. (2012) · Small · doi:10.1002/smll.201101594 · Cited by 1,546
Electrochemical Non-enzymatic Glucose Sensors: A Perspective and an Evaluation
Toghill, K. E., & Compton, R. G. (2010) · International Journal of Electrochemical Science · doi:10.1016/s1452-3981(23)15359-4 · Cited by 926
A Comprehensive Review of Glucose Biosensors Based on Nanostructured Metal-Oxides
Rahman, M. M., Ahammad, A. J. S., Jin, J.-H., Ahn, S. J., & Lee, J.-J. (2010) · Sensors · doi:10.3390/s100504855 · Cited by 762
“Ir, Ru, Cu, and Pd [2,33-37]; and (3) metal-dispersed carbon nanotubes (CNTs) framework in which”
BackgroundJiang, L.-C., & Zhang, W.-D. (2010) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.10.038 · Cited by 667
Self-citationEfficient electrochemical production of glucaric acid and H2 via glucose electrolysis
Liu, W.-J., Xu, Z., Zhao, D., Pan, X.-Q., Li, H.-C., Hu, X., Fan, Z.-Y., Wang, W.-K., Zhao, G.-H., Jin, S., et al. (2020) · Nature Communications · doi:10.1038/s41467-019-14157-3 · Cited by 612
Gao, C., Guo, Z., Liu, J.-H., & Huang, X.-J. (2012) · Nanoscale · doi:10.1039/c2nr11757f · Cited by 424
Nonenzymatic electrochemical glucose sensor based on MnO2/MWNTs nanocomposite
Chen, J., Zhang, W.-D., & Ye, J.-S. (2008) · Electrochemistry Communications · doi:10.1016/j.elecom.2008.06.022 · Cited by 408
Self-citationCuO Nanospheres Based Nonenzymatic Glucose Sensor
Reitz, E., Jia, W., Gentile, M., Wang, Y., & Lei, Y. (2008) · Electroanalysis · doi:10.1002/elan.200804327 · Cited by 346
Xiao, F., Zhao, F., Mei, D., Mo, Z., & Zeng, B. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.04.045 · Cited by 344
Xiao, J., Kuang, Q., Yang, S., Xiao, F., Wang, S., & Guo, L. (2013) · Scientific Reports · doi:10.1038/srep02300 · Cited by 332
Kang, X., Mai, Z., Zou, X., Cai, P., & Mo, J. (2007) · Analytical Biochemistry · doi:10.1016/j.ab.2007.07.005 · Cited by 289
Cui, H.-F., Ye, J.-S., Zhang, W.-D., Li, C.-M., Luong, J. H. T., & Sheu, F.-S. (2007) · Analytica Chimica Acta · doi:10.1016/j.aca.2007.05.047 · Cited by 254
Self-citationGold nanowire array electrode for non-enzymatic voltammetric and amperometric glucose detection
Cherevko, S., & Chung, C.-H. (2009) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2009.07.023 · Cited by 251
Hsu, Y.-W., Hsu, T.-K., Sun, C.-L., Nien, Y.-T., Pu, N.-W., & Ger, M.-D. (2012) · Electrochimica Acta · doi:10.1016/j.electacta.2012.03.094 · Cited by 247
Wu, H.-X., Cao, W.-M., Li, Y., Liu, G., Wen, Y., Yang, H.-F., & Yang, S.-P. (2010) · Electrochimica Acta · doi:10.1016/j.electacta.2010.02.017 · Cited by 235
Pt–Pb nanowire array electrode for enzyme-free glucose detection
Bai, Y., Sun, Y., & Sun, C. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.06.003 · Cited by 207
Electrochemical nonenzymatic sensing of glucose using advanced nanomaterials
Dhara, K., & Mahapatra, D. R. (2018) · Microchimica Acta · doi:10.1007/s00604-017-2609-1 · Cited by 207
A highly sensitive nonenzymatic glucose sensor based on NiO-modified multi-walled carbon nanotubes
Zhang, W.-D., Chen, J., Jiang, L.-C., Yu, Y.-X., & Zhang, J.-Q. (2010) · Microchimica Acta · doi:10.1007/s00604-010-0288-2 · Cited by 205
“These stable, high-density, well-aligned MWCNTs with a large, electrochemically accessible surface area, high purity and high electrical conductivity, have been demonstrated to be high-performance electrode materials for electrochemical sensors [11, 25, 33, 34].”
BackgroundSelf-citationJeon, I.-Y., Yu, D., Bae, S.-Y., Choi, H.-J., Chang, D. W., Dai, L., & Baek, J.-B. (2011) · Chemistry of Materials · doi:10.1021/cm201542m · Cited by 175
Metal nanostructures for non-enzymatic glucose sensing
Tee, S. Y., Teng, C. P., & Ye, E. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2016.04.009 · Cited by 172
Upadhyay, S., Rao, G. R., Sharma, M. K., Bhattacharya, B. K., Rao, V. K., & Vijayaraghavan, R. (2009) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2009.08.036 · Cited by 169
“The PtNPs in combination with other etals such as gold, lead, tin and CNT showed better electrocatlytic properties than their counterparts (Cui et al., 2006; Kang et l., 2007; Lang et al., 2004; Zou et al., 2008,).”
BackgroundCuS nanotubes for ultrasensitive nonenzymatic glucose sensors
Zhang, X., Wang, G., Gu, A., Wei, Y., & Fang, B. (2008) · Chemical Communications · doi:10.1039/b814725f · Cited by 158
Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination
El Khatib, K. M., & Abdel Hameed, R. M. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.01.042 · Cited by 158
Metadata
- Authors
- Cui, H.-F., Ye, J.-S., Liu, X., Zhang, W.-D., & Sheu, F.-S.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2006-04-11
- Volume
- 17
- Issue
- 9
- Pages
- 2334-2339
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2034071868
- Cited by
- 196
- References
- 21
- FWCI
- 12.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.