Experimental validation of atomic force microscopy-based cell elasticity measurements
Open accessThe DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Abstract
Atomic force microscopy (AFM) is widely used for measuring the elasticity of living cells yielding values ranging from 100 Pa to 100 kPa, much larger than those obtained using bead-tracking microrheology or micropipette aspiration (100-500 Pa). AFM elasticity measurements appear dependent on tip geometry with pyramidal tips yielding elasticities 2-3 fold larger than spherical tips, an effect generally attributed to the larger contact area of spherical tips. In AFM elasticity measurements, experimental force-indentation curves are analyzed using contact mechanics models that infer the tip-cell contact area from the tip geometry and indentation depth. The validity of these assumptions has never been verified. Here we utilize combined AFM-confocal microscopy of epithelial cells expressing a GFP-tagged membrane marker to directly characterize the indentation geometry and measure the indentation depth. Comparison with data derived from AFM force-indentation curves showed that the experimentally measured contact area for spherical tips agrees well with predicted values, whereas for pyramidal tips, the contact area can be grossly underestimated at forces larger than ∼0.2 nN leading to a greater than two-fold overestimation of elasticity. These data suggest that a re-examination of absolute cellular elasticities reported in the literature may be necessary and we suggest guidelines for avoiding elasticity measurement artefacts introduced by extraneous cantilever-cell contact.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Force measurements with the atomic force microscope: Technique, interpretation and applications
Butt, H.-J., Cappella, B., & Kappl, M. (2005) · Surface Science Reports · doi:10.1016/j.surfrep.2005.08.003 · Cited by 4,297
Calibration of atomic-force microscope tips
Hutter, J. L., & Bechhoefer, J. (1993) · Review of Scientific Instruments · doi:10.1063/1.1143970 · Cited by 4,194 · cited 1×
“The cantilevers were calibrated by the thermal noise method before each experiment [22].”
MethodManiotis, A. J., Chen, C. S., & Ingber, D. E. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.3.849 · Cited by 1,601
Micropipette aspiration of living cells
Hochmuth, R. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00175-x · Cited by 1,423 · cited 2×
“Unlike previous measurements, our validated measurements were comparable in magnitude to elasticities obtained using other measurement methods such as micropipette aspiration or microrheology (100–500 Pa [13, 14]).”
MethodResultDetermination of Elastic Moduli of Thin Layers of Soft Material Using the Atomic Force Microscope
Dimitriadis, E. K., Horkay, F., Maresca, J., Kachar, B., & Chadwick, R. S. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75620-8 · Cited by 1,230
Rotsch, C., & Radmacher, M. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76614-8 · Cited by 971
Ory, D. S., Neugeboren, B. A., & Mulligan, R. C. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.21.11400 · Cited by 912 · cited 2×
“Briefly, PH-PLCδ-GFP (a kind gift from Dr Tamas Balla, NIH) was excised from EGFPN1 (Takara-Clontech, CA, USA), inserted into the retroviral vector pLNCX2 (Takara-Clontech), and transfected into 293GPG cells for packaging (a kind gift from Prof Daniel Ory, Washington University [21]).”
MethodAFM indentation study of breast cancer cells
Li, Q. S., Lee, G. Y. H., Ong, C. N., & Lim, C. T. (2008) · Biochemical and Biophysical Research Communications · doi:10.1016/j.bbrc.2008.07.078 · Cited by 897
Atomic force microscopy probing of cell elasticity
Kuznetsova, T. G., Starodubtseva, M. N., Yegorenkov, N. I., Chizhik, S. A., & Zhdanov, R. I. (2007) · Micron · doi:10.1016/j.micron.2007.06.011 · Cited by 794
Particle-Tracking Microrheology of Living Cells: Principles and Applications
Wirtz, D. (2009) · Annual Review of Biophysics · doi:10.1146/annurev.biophys.050708.133724 · Cited by 670 · cited 2×
“Unlike previous measurements, our validated measurements were comparable in magnitude to elasticities obtained using other measurement methods such as micropipette aspiration or microrheology (100–500 Pa [13, 14]).”
MethodResult
Cited by
Calvo, F., Ege, N., Grande-Garcia, A., Hooper, S., Jenkins, R. P., Chaudhry, S. I., Harrington, K., Williamson, P., Moeendarbary, E., Charras, G., et al. (2013) · Nature Cell Biology · doi:10.1038/ncb2756 · Cited by 1,478
Self-citationActin cortex mechanics and cellular morphogenesis
Salbreux, G., Charras, G., & Paluch, E. (2012) · Trends in Cell Biology · doi:10.1016/j.tcb.2012.07.001 · Cited by 871
Self-citationThe cytoplasm of living cells behaves as a poroelastic material
Moeendarbary, E., Valon, L., Fritzsche, M., Harris, A. R., Moulding, D. A., Thrasher, A. J., Stride, E., Mahadevan, L., & Charras, G. T. (2013) · Nature Materials · doi:10.1038/nmat3517 · Cited by 686
Self-citationRice, A. J., Cortes, E., Lachowski, D., Cheung, B. C. H., Karim, S. A., Morton, J. P., & del Río Hernández, A. (2017) · Oncogenesis · doi:10.1038/oncsis.2017.54 · Cited by 523
Characterizing the mechanics of cultured cell monolayers
Harris, A. R., Peter, L., Bellis, J., Baum, B., Kabla, A. J., & Charras, G. T. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1213301109 · Cited by 387
Self-citationCell mechanics: principles, practices, and prospects
Moeendarbary, E., & Harris, A. R. (2014) · WIREs Systems Biology and Medicine · doi:10.1002/wsbm.1275 · Cited by 342
Self-citationA molecular mechanotransduction pathway regulates collective migration of epithelial cells
Das, T., Safferling, K., Rausch, S., Grabe, N., Boehm, H., & Spatz, J. P. (2015) · Nature Cell Biology · doi:10.1038/ncb3115 · Cited by 335
Dividing Cells Regulate Their Lipid Composition and Localization
Atilla-Gokcumen, G. E., Muro, E., Relat-Goberna, J., Sasse, S., Bedigian, A., Coughlin, M. L., Garcia-Manyes, S., & Eggert, U. S. (2014) · Cell · doi:10.1016/j.cell.2013.12.015 · Cited by 312
Measuring viscoelasticity of soft biological samples using atomic force microscopy
Efremov, Y. M., Okajima, T., & Raman, A. (2020) · Soft Matter · doi:10.1039/c9sm01020c · Cited by 243
Cellular Pressure and Volume Regulation and Implications for Cell Mechanics
Jiang, H., & Sun, S. X. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.06.021 · Cited by 219
“For such high loading rates, the cell volume should be nearly conserved, as we predict in this model; cells should appear to be incompressible (33,34).”
BackgroundMethodHigh-Throughput Assessment of Cellular Mechanical Properties
Darling, E. M., & Di Carlo, D. (2015) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071114-040545 · Cited by 214
“A spherical tip provides more conformal contact and lower local strains than sharp tips, and, if appropriately sized, provides a more accurate bulk measurement of the mechanical property of the cell, lessening the influence of individual intracellular components (93).”
Cell-geometry-dependent changes in plasma membrane order direct stem cell signalling and fate
von Erlach, T. C., Bertazzo, S., Wozniak, M. A., Horejs, C.-M., Maynard, S. A., Attwood, S., Robinson, B. K., Autefage, H., Kallepitis, C., del Río Hernández, A., et al. (2018) · Nature Materials · doi:10.1038/s41563-017-0014-0 · Cited by 204
The Effect of the Endothelial Cell Cortex on Atomic Force Microscopy Measurements
Vargas-Pinto, R., Gong, H., Vahabikashi, A., & Johnson, M. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.05.034 · Cited by 182
Force spectroscopy of single cells using atomic force microscopy
Viljoen, A., Mathelié-Guinlet, M., Ray, A., Strohmeyer, N., Oh, Y. J., Hinterdorfer, P., Müller, D. J., Alsteens, D., & Dufrêne, Y. F. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00062-x · Cited by 176
FAK controls the mechanical activation of YAP, a transcriptional regulator required for durotaxis
Lachowski, D., Cortes, E., Robinson, B., Rice, A., Rombouts, K., & Del Río Hernández, A. E. (2018) · The FASEB Journal · doi:10.1096/fj.201700721r · Cited by 175
“The force–distance curves were used to calculate elastic moduli in the AFM software through the application of the Hertz contact model (19).”
Actin kinetics shapes cortical network structure and mechanics
Fritzsche, M., Erlenkämper, C., Moeendarbary, E., Charras, G., & Kruse, K. (2016) · Science Advances · doi:10.1126/sciadv.1501337 · Cited by 170
“Analysis of force indentations was restricted to depths of 100 to 500 nm (leading to forces less than 200 pN) to maximize the contribution of cortex stiffness to cantilever deflection, enabling us to probe cell cortex elasticity while minimizing contributions from the cytoplasm (50, 60).”
BackgroundSelf-citation
Metadata
- Authors
- Harris, A. R., & Charras, G. T.
- Venue
- Nanotechnology
- Publisher
- IOP Publishing
- Published
- 2011-07-28
- Volume
- 22
- Issue
- 34
- Pages
- 345102
- ISSN
- 0957-4484 (ISSN-L)
- 1361-6528
- OpenAlex
- W2041205033
- Cited by
- 195
- References
- 27
- FWCI
- 5.73
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.