Open accessAbstract
A novel structure for chronically implantable cortical electrodes using polyimide bio-polymer was devised, which provides both flexibility for micro-motion compliance between brain tissues and the skull and at the brain/implant interface and stiffness for better surgical handling. A 5–10 µm thick silicon backbone layer was attached to the tip of the electrode to enhance the structural stiffness. This stiff segment was then followed by a 1 mm flexible segment without a silicon backbone layer. The fabricated implants have tri-shanks with five recording sites (20 µm × 20 µm) and two vias of 40 µm × 40 µm on each shank. In vitro cytotoxicity tests of prototype implants revealed no adverse toxic effects on cells. Bench test impedance values were assessed, resulting in an average impedance value of ∼2 MΩ at 1 KHz. For a 5 µm thick silicon backbone electrode, the stiffness of polyimide-based electrodes was increased ten times over that of electrodes without the silicon backbone layer. Furthermore, polyimide-based electrodes with 5 µm and 10 µm thick silicon backbone layer penetrated pia of rat brain without buckling that has been observed in implants without silicon reinforcement.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A high-yield microassembly structure for three-dimensional microelectrode arrays
Bai, Q., Wise, K. D., & Anderson, D. J. (2000) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.827288 · Cited by 245
Rousche, P. J., & Normann, R. A. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.750552 · Cited by 187
Cited by
Response of brain tissue to chronically implanted neural electrodes
Polikov, V. S., Tresco, P. A., & Reichert, W. M. (2005) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2005.08.015 · Cited by 1,896
Recent advances in nanocellulose for biomedical applications
Jorfi, M., & Foster, E. J. (2015) · Journal of Applied Polymer Science · doi:10.1002/app.41719 · Cited by 738
A Review of Organic and Inorganic Biomaterials for Neural Interfaces
Fattahi, P., Yang, G., Kim, G., & Abidian, M. R. (2014) · Advanced Materials · doi:10.1002/adma.201304496 · Cited by 580
Hassler, C., Boretius, T., & Stieglitz, T. (2011) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.22169 · Cited by 501
Multifunctional Nanobiomaterials for Neural Interfaces
Abidian, M. R., & Martin, D. C. (2009) · Advanced Functional Materials · doi:10.1002/adfm.200801473 · Cited by 416
Metadata
- Authors
- Lee, K.-K., He, J., Singh, A., Massia, S., Ehteshami, G., Kim, B., & Raupp, G.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2003-08-19
- Volume
- 14
- Issue
- 1
- Pages
- 32-37
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W1972080956
- Cited by
- 161
- References
- 2
- FWCI
- 1.00
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Polyimide-based intracortical neural implant with improved structural stiffness. https://app.cochat.ai/papers/10.1088/0960-1317/14/1/305
- The paper
- Lee, K.-K., He, J., Singh, A., Massia, S., Ehteshami, G., Kim, B., & Raupp, G. (2004). Polyimide-based intracortical neural implant with improved structural stiffness. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/14/1/305
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.