Lab-on-chip technologies: making a microfluidic network and coupling it into a complete microsystem—a review
Open accessThe DOI matches its Crossref record; 84 of the 84 references it cites were found in a registry or an index.
Abstract
Microfluidics is an emerging field that has given rise to a large number of scientific and technological developments over the last few years. This review reports on the use of various materials, such as silicon, glass and polymers, and their related technologies for the manufacturing of simple microchannels and complex systems. It also presents the main application fields concerned with the different technologies and the most significant results reported by academic and industrial teams. Finally, it demonstrates the advantage of developing approaches for associating polymer technologies for manufacturing of fluidic elements with integration of active or sensitive elements, particularly silicon devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Young, R. J., & Lovell, P. A. (1992) · Springer eBooks · doi:10.1007/978-1-4615-3478-5 · Cited by 2,116
Microfluidic devices fabricated in Poly(dimethylsiloxane) for biological studies
Sia, S. K., & Whitesides, G. M. (2003) · ELECTROPHORESIS · doi:10.1002/elps.200305584 · Cited by 1,717
Seidel, H., Csepregi, L., Heuberger, A., & Baumgärtel, H. (1990) · Journal of The Electrochemical Society · doi:10.1149/1.2086277 · Cited by 1,633
A gas chromatographic air analyzer fabricated on a silicon wafer
Terry, S. C., Jerman, J. H., & Angell, J. B. (1979) · IEEE Transactions on Electron Devices · doi:10.1109/t-ed.1979.19791 · Cited by 1,452
An Integrated Nanoliter DNA Analysis Device
Burns, M. A., Johnson, B. N., Brahmasandra, S. N., Handique, K., Webster, J. R., Krishnan, M., Sammarco, T. S., Man, P. M., Jones, D., Heldsinger, D., et al. (1998) · Science · doi:10.1126/science.282.5388.484 · Cited by 1,299
An introduction to the mechanical properties of solid polymers
(2004) · Choice Reviews Online · doi:10.5860/choice.42-2247 · Cited by 1,284
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Seemann, R., Brinkmann, M., Pfohl, T., & Herminghaus, S. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/1/016601 · Cited by 1,049
Wongkaew, N., Simsek, M., Griesche, C., & Baeumner, A. J. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.8b00172 · Cited by 657
Wong, I., & Ho, C.-M. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-009-0443-4 · Cited by 531
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Lab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
A practical guide for the fabrication of microfluidic devices using glass and silicon
Iliescu, C., Taylor, H., Avram, M., Miao, J., & Franssila, S. (2012) · Biomicrofluidics · doi:10.1063/1.3689939 · Cited by 385
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Ultra-thin chips for high-performance flexible electronics
Gupta, S., Navaraj, W. T., Lorenzelli, L., & Dahiya, R. (2018) · npj Flexible Electronics · doi:10.1038/s41528-018-0021-5 · Cited by 363
Recent Advances in Analytical Chemistry by 3D Printing
Gross, B., Lockwood, S. Y., & Spence, D. M. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04344 · Cited by 359
3D printing for chemical, pharmaceutical and biological applications
Capel, A. J., Rimington, R. P., Lewis, M. P., & Christie, S. D. R. (2018) · Nature Reviews Chemistry · doi:10.1038/s41570-018-0058-y · Cited by 312
Lab on Fiber Technology for biological sensing applications
Vaiano, P., Carotenuto, B., Pisco, M., Ricciardi, A., Quero, G., Consales, M., Crescitelli, A., Esposito, E., & Cusano, A. (2016) · Laser & Photonics Reviews · doi:10.1002/lpor.201600111 · Cited by 306
Campbell, S. B., Wu, Q., Yazbeck, J., Liu, C., Okhovatian, S., & Radisic, M. (2021) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.0c00640 · Cited by 297
Evolution of Biochip Technology: A Review from Lab-on-a-Chip to Organ-on-a-Chip
Azizipour, N., Avazpour, R., Rosenzweig, D. H., Sawan, M., & Ajji, A. (2020) · Micromachines · doi:10.3390/mi11060599 · Cited by 277
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
SU‐8 as a structural material for labs‐on‐chips and microelectromechanical systems
Abgrall, P., Conedera, V., Camon, H., Gue, A., & Nguyen, N. (2007) · ELECTROPHORESIS · doi:10.1002/elps.200700333 · Cited by 242
Self-citationFlexible Microfluidics: Fundamentals, Recent Developments, and Applications
Fallahi, H., Zhang, J., Phan, H.-P., & Nguyen, N.-T. (2019) · Micromachines · doi:10.3390/mi10120830 · Cited by 224
“Third, microfluidic systems are often portable and can be used for point-of-care applications or deployed in remote locations [33,34].”
BackgroundDesign of capillary microfluidics for spinning cell-laden microfibers
Yu, Y., Shang, L., Guo, J., Wang, J., & Zhao, Y. (2018) · Nature Protocols · doi:10.1038/s41596-018-0051-4 · Cited by 218
Integration and detection of biochemical assays in digital microfluidic LOC devices
Malic, L., Brassard, D., Veres, T., & Tabrizian, M. (2010) · Lab Chip · doi:10.1039/b917668c · Cited by 207
Paper-based microfluidic analytical devices for colorimetric detection of toxic ions: A review
Sriram, G., Bhat, M. P., Patil, P., Uthappa, U. T., Jung, H.-Y., Altalhi, T., Kumeria, T., Aminabhavi, T. M., Pai, R. K., Madhuprasad, et al. (2017) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2017.06.005 · Cited by 204
Lab-on-fiber technology: a new vision for chemical and biological sensing
Ricciardi, A., Crescitelli, A., Vaiano, P., Quero, G., Consales, M., Pisco, M., Esposito, E., & Cusano, A. (2015) · The Analyst · doi:10.1039/c5an01241d · Cited by 204
Three-dimensional femtosecond laser processing for lab-on-a-chip applications
Sima, F., Sugioka, K., Vázquez, R. M., Osellame, R., Kelemen, L., & Ormos, P. (2018) · Nanophotonics · doi:10.1515/nanoph-2017-0097 · Cited by 196
Optical Oxygen Sensors for Applications in Microfluidic Cell Culture
Grist, S. M., Chrostowski, L., & Cheung, K. C. (2010) · Sensors · doi:10.3390/s101009286 · Cited by 169
“In many cases, the eventual goal for microfluidic systems is to create “lab-on-a-chip”-type microfluidic devices, which integrate all of the necessary steps for analysis onto a single chip [25,26].”
BackgroundBasement membrane properties and their recapitulation in organ-on-chip applications
Salimbeigi, G., Vrana, N. E., Ghaemmaghami, A. M., Huri, P. Y., & McGuinness, G. B. (2022) · Materials Today Bio · doi:10.1016/j.mtbio.2022.100301 · Cited by 57
Metadata
- Authors
- Abgrall, P., & Gué, A.-M.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2007-04-24
- Volume
- 17
- Issue
- 5
- Pages
- R15-R49
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2060921962
- Cited by
- 561
- References
- 84
- FWCI
- 18.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.