Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
Parylene C, an emerging material in microelectromechanical systems, is of particular interest in biomedical and lab-on-a-chip applications where stable, chemically inert surfaces are desired. Practical implementation of Parylene C as a structural material requires the development of micropatterning techniques for its selective removal. Dry etching methods are currently the most suitable for batch processing of Parylene structures. A performance comparison of three different modes of Parylene C plasma etching was conducted using oxygen as the primary reactive species. Plasma, reactive ion and deep reactive ion etching techniques were explored. In addition, a new switched chemistry process with alternating cycles of fluoropolymer deposition and oxygen plasma etching was examined to produce structures with vertical sidewalls. Vertical etch rates, lateral etch rates, anisotropy and sidewall angles were characterized for each of the methods. This detailed characterization was enabled by the application of replica casting to obtain cross sections of etched structures in a non-destructive manner. Application of the developed etch recipes to the fabrication of complex Parylene C microstructures is also discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Plasma Discharges and Materials Processing
Lieberman, M. A., & Lichtenberg, A. J. (2005) · doi:10.1002/0471724254 · Cited by 4,748 · cited 1×
“The addition of fluorine containing gases such as CF4 and SF6 is thought to increase oxygen atom concentration compared to a pure O2 plasma and increase etch rate or to produce HF and leave unsaturated or radical sites for oxygen atom attack [22, 44, 45].”
Kirk‐Othmer Encyclopedia of Chemical Technology
(2007) · Reference Reviews · doi:10.1108/09504120710728879 · Cited by 1,156
Plasma deposition, treatment, and etching of polymers
d’Agostino, R. (1990) · Cited by 1,108
A New, General Synthetic Method for the Preparation of Linear Poly‐p‐xylylenes
Gorham, W. F. (1966) · Journal of Polymer Science Part A-1: Polymer Chemistry · doi:10.1002/pol.1966.150041209 · Cited by 666
Plasma etching : an introduction
Manos, D. M., & Flamm, D. L. (1989) · Cited by 496
Parylene flexible neural probes integrated with microfluidic channels
Takeuchi, S., Ziegler, D., Yoshida, Y., Mabuchi, K., & Suzuki, T. (2005) · Lab on a Chip · doi:10.1039/b417497f · Cited by 364 · cited 1×
“For example, Parylene C-based devices have been demonstrated as platforms for neuronal growth [14–16] and in implantable neuronal probes [17].”
Xie, J., Miao, Y., Shih, J., Tai, Y.-C., & Lee, T. D. (2005) · Analytical Chemistry · doi:10.1021/ac0510888 · Cited by 162
Self-citationVapor‐based polymer coatings for potential biomedical applications
Lahann, J. (2006) · Polymer International · doi:10.1002/pi.2098 · Cited by 154
Restoring lost cognitive function.
Berger, T. W., Ahuja, A., Courellis, S. H., Deadwyler, S. A., Erinjippurath, G., Gerhardt, G. A., Gholmieh, G., Granacki, J. J., Hampson, R., Hsaio, M. C., et al. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1511498 · Cited by 148
Parylene micromolding, a rapid and low-cost fabrication method for parylene microchannel
Noh, H. “., Huang, Y. H., & Hesketh, P. J. (2004) · Sensors and Actuators B Chemical · doi:10.1016/j.snb.2003.09.038 · Cited by 135 · cited 1×
“patterned mold and then thermocompression bonding with a second Parylene film was developed as an alternative to surface micromachining of microchannels [39, 40].”
Weisenberg, B. A., & Mooradian, D. L. (2002) · Journal of Biomedical Materials Research · doi:10.1002/jbm.10076 · Cited by 133 · cited 1×
“Its biocompatibility, biostability, low cytotoxicity and resistance against hydrolytic degradation [1, 12, 13] have resulted in increasing popularity of Parylene C in micro- and”
Toward the ultimate metal microelectrode
Loeb, G. E., Peck, R. A., & Martyniuk, J. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00107-7 · Cited by 126 · cited 1×
“Selective removal by ultraviolet laser ablation [35, 36] and manual mechanical removal on wire microelectrodes [37] has also been reported.”
Wang, X.-Q., Lin, Q., & Tai, Y. (1999) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.1999.746801 · Cited by 107 · cited 1×
“Parylene etching has been demonstrated in multiple modes including plasma etching [19, 25, 26], reactive ion beam etching (RIBE) [27], reactive ion etching (RIE) [28, 29] and high-density plasma etching [30].”
Self-citationPlasma Etching of Organic Polymers
Egitto, F. D., Vukanović, V., & Taylor, G. N. (1990) · Elsevier eBooks · doi:10.1016/b978-0-12-200430-8.50011-7 · Cited by 60
Laser exposure of Parylene-C insulated microelectrodes
Schmidt, E. M., Bak, M. J., & Christensen, P. (1995) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(95)00060-7 · Cited by 60 · cited 1×
“Selective removal by ultraviolet laser ablation [35, 36] and manual mechanical removal on wire microelectrodes [37] has also been reported.”
Biocomplatible parylene neurocages
Tooker, A., Meng, E. F., Erickson, J., Tai, Y., & Pine, J. (2005) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2005.1549727 · Cited by 48 · cited 1×
“For example, Parylene C-based devices have been demonstrated as platforms for neuronal growth [14–16] and in implantable neuronal probes [17].”
Self-citationDefinition of the Geometric Area of a Microelectrode Tip by Plasma Etching of Parylene
Levy, B. P., Campbell, S. L., & Rose, T. L. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325872 · Cited by 15 · cited 1×
“Parylene etching has been demonstrated in multiple modes including plasma etching [19, 25, 26], reactive ion beam etching (RIBE) [27], reactive ion etching (RIE) [28, 29] and high-density plasma etching [30].”
Selvarasah, S., Chao, S.-H., Chen, C.-L., Mao, D., Hopwood, J., Ryley, S., Sridhar, S., Khademhosseini, A., BUSNAINA, A. A., & Dokmeci, M. R. (2007) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/sensor.2007.4300185 · Cited by 12 · cited 2×
“of Parylene C can be etched using an Al mask [46].”
MethodPhotodefinable silicone MEMS gaskets and O-rings for microfluidics packaging
Miserendino, S., & Tai, Y. (2007) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2007.4433144 · Cited by 3
Self-citation
Cited by
Micromachining of Parylene C for bioMEMS
Kim, B. J., & Meng, E. (2016) · Polymers for Advanced Technologies · doi:10.1002/pat.3729 · Cited by 204
Self-citationTechniques and Considerations in the Microfabrication of Parylene C Microelectromechanical Systems
Ortigoza-Diaz, J., Scholten, K., Larson, C., Cobo, A., Hudson, T., Yoo, J., Baldwin, A., Weltman Hirschberg, A., & Meng, E. (2018) · Micromachines · doi:10.3390/mi9090422 · Cited by 164
“Across a broad range of processes, AZ P4620, a positivetone photoresist, was used as a Parylene etch mask for both O2 RIE and an O2 DRIE process (presented in [113]) to etch a variety of structures into Parylene film, ranging from 1 to 15 μm deep.”
MethodSelf-citationMaterials for microfabricated implantable devices: a review
Scholten, K., & Meng, E. (2015) · Lab on a Chip · doi:10.1039/c5lc00809c · Cited by 161
Self-citationWang, R., Huang, X., Liu, G., Wang, W., Dong, F., & Li, Z. (2010) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2009.2039773 · Cited by 63
A Flexible Microneedle Electrode Array With Solid Silicon Needles
Wang, R., Zhao, W., Wang, W., & Li, Z. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2012.2203790 · Cited by 55
Metadata
- Authors
- Meng, E., Li, P.-Y., & Tai, Y.-C.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2008-02-22
- Volume
- 18
- Issue
- 4
- Pages
- 045004
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2030786835
- Cited by
- 159
- References
- 19
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.