Cited by 55Neuroscience and Neural EngineeringAdvanced MEMS and NEMS TechnologiesAnalog and Mixed-Signal Circuit Design

A Flexible Microneedle Electrode Array With Solid Silicon Needles

Wang, Renxin, Zhao, Wei, Wang, Wei, Li, Zhihong·2012·Journal of Microelectromechanical Systems

Abstract

We propose a novel fabrication process to make flexible microneedle electrode array. The process includes creation of a silicon microneedle electrode array using a silicon-on-insulator substrate followed by its release using parylene films as the support material. The proposed structure provides flexibility of a parylene thin film and rigidity of a silicon structure. Using tissue-penetration tests and impedance spectroscopy, we demonstrate that such a structure is promising in invasive neural electrical stimulation and recording.

Integrity signals

Registry

Crossref · 10.1109/jmems.2012.2203790

Cites

18 of 18 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Wang, R., Zhao, W., Wang, W., & Li, Z.
Affiliations
  • Peking University (CN)
  • Chinese Academy of Sciences (CN)
Venue
Journal of Microelectromechanical Systems
Published
2012-10
Volume
21
Issue
5
Pages
1084-1089
ISSN
  • 1057-7157 (ISSN-L)
  • 1941-0158
OpenAlex
W2011118497
Cited by
55
References
18
Citations by year
2026: 1 · 2025: 7 · 2024: 2 · 2023: 1 · 2022: 4 · 2021: 6 · 2020: 2 · 2019: 3 · 2018: 6 · 2017: 5 · 2016: 5 · 2015: 5 · 2014: 3 · 2013: 5
FWCI
1.71
Type
journal article
Language
en
Open access
closed
Locations
Journal of Microelectromechanical Systems (publishedVersion)
Funders
Tsinghua University
Topics
  • Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced MEMS and NEMS Technologies
  • Physical Sciences › Engineering › Biomedical Engineering › Analog and Mixed-Signal Circuit Design
Keywords
silicon microneedles, silicon-on-insulator, tissue penetration, neural recording, flexible electronics, impedance spectroscopy

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review