Determining the optimal PDMS–PDMS bonding technique for microfluidic devices
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
A number of polydimethysiloxane (PDMS) bonding techniques have been reported in the literature over the last several years as the focus on multilayer PDMS microfluidic devices has increased. Oxygen plasma bonding, despite cost, additional fabrication time and inconsistent bonding results, has remained a widely used method for bonding PDMS layers. A comparative study of four rapid, inexpensive alternative PDMS–PDMS bonding approaches was undertaken to determine relative bond strength. These include corona discharge, partial curing, cross-linker variation and uncured PDMS adhesive. Partial curing and uncured PDMS adhesive demonstrated a considerable improvement in bond strength and consistency by retaining average bond strengths of over 600 kPa, which was more than double the average bond strength of oxygen plasma. A description of each technique and their performance relative to oxygen plasma bonding is included.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Bhattacharya, S., Datta, A., Berg, J. M., & Gangopadhyay, S. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.844746 · Cited by 859
Effenhauser, C. S., Bruin, G. J. M., Paulus, A., & Ehrat, M. (1997) · Analytical Chemistry · doi:10.1021/ac9703919 · Cited by 640
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
PDMS bonding by means of a portable, low-cost corona system
Haubert, K., Drier, T., & Beebe, D. (2006) · Lab on a Chip · doi:10.1039/b610567j · Cited by 307
Duffy, D. C., Schueller, O. J. A., Brittain, S. T., & Whitesides, G. M. (1999) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/9/3/301 · Cited by 205
A PDMS-based gas permeation pump for on-chip fluid handling in microfluidic devices
Eddings, M. A., & Gale, B. K. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/11/021 · Cited by 160
Self-citationSamel, B., Chowdhury, M. K., & Stemme, G. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/8/038 · Cited by 89
A disposable, dead volume-free and leak-free in-plane PDMS microvalve
Go, J. S., & Shoji, S. (2004) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2003.12.028 · Cited by 85
Cited by
3D printing of soft robotic systems
Wallin, T. J., Pikul, J., & Shepherd, R. F. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0002-2 · Cited by 942
Bonding of thermoplastic polymer microfluidics
Tsao, C.-W., & DeVoe, D. L. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0361-x · Cited by 601
Bend, stretch, and touch: Locating a finger on an actively deformed transparent sensor array
Sarwar, M. S., Dobashi, Y., Preston, C., Wyss, J. K. M., Mirabbasi, S., & Madden, J. D. W. (2017) · Science Advances · doi:10.1126/sciadv.1602200 · Cited by 370
Tsao, C.-W. (2016) · Micromachines · doi:10.3390/mi7120225 · Cited by 367
An outlook on microfluidics: the promise and the challenge
Battat, S., Weitz, D. A., & Whitesides, G. M. (2022) · Lab on a Chip · doi:10.1039/d1lc00731a · Cited by 333
Shakeri, A., Khan, S., & Didar, T. F. (2021) · Lab on a Chip · doi:10.1039/d1lc00288k · Cited by 312
Highly Stretchable and Self‐Deformable Alternating Current Electroluminescent Devices
Wang, J., Yan, C., Chee, K. J., & Lee, P. S. (2015) · Advanced Materials · doi:10.1002/adma.201405486 · Cited by 289
A facile route for irreversible bonding of plastic-PDMS hybrid microdevices at room temperature
Tang, L., & Lee, N. Y. (2010) · Lab on a Chip · doi:10.1039/b924753j · Cited by 267
Sugioka, K., Xu, J., Wu, D., Hanada, Y., Wang, Z., Cheng, Y., & Midorikawa, K. (2014) · Lab Chip · doi:10.1039/c4lc00548a · Cited by 259
Flexible Plasmonics on Unconventional and Nonplanar Substrates
Aksu, S., Huang, M., Artar, A., Yanik, A. A., Selvarasah, S., Dokmeci, M. R., & Altug, H. (2011) · Advanced Materials · doi:10.1002/adma.201102430 · Cited by 253
Chan, H. N., Chen, Y., Shu, Y., Chen, Y., Tian, Q., & Wu, H. (2015) · Microfluidics and Nanofluidics · doi:10.1007/s10404-014-1542-4 · Cited by 244
Silicones for Stretchable and Durable Soft Devices: Beyond Sylgard-184
Park, S., Mondal, K., Treadway, R. M., Kumar, V., Ma, S., Holbery, J. D., & Dickey, M. D. (2018) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b18394 · Cited by 227
PDMS Bonding Technologies for Microfluidic Applications: A Review
Borók, A., Laboda, K., & Bonyár, A. (2021) · Biosensors · doi:10.3390/bios11080292 · Cited by 225
“PDMS pre-polymer gluing 12 671 kPa average burst pressure (air), variation: 545–690 kPa [60]”
BackgroundMethodResultInfluentialFlexible Microfluidics: Fundamentals, Recent Developments, and Applications
Fallahi, H., Zhang, J., Phan, H.-P., & Nguyen, N.-T. (2019) · Micromachines · doi:10.3390/mi10120830 · Cited by 224
“The hydrophobic ature f PDMS, which is n t favourable for applications that require surface adhesion such as cell culture [73,74], can be overcome by applying oxygen plasma to make t e PDMS surface hydrophilic due to polar silanol groups, leading to better wetting [75,76].”
BackgroundFabrication of fillable microparticles and other complex 3D microstructures
McHugh, K. J., Nguyen, T. D., Linehan, A. R., Yang, D., Behrens, A. M., Rose, S., Tochka, Z. L., Tzeng, S. Y., Norman, J. J., Anselmo, A. C., et al. (2017) · Science · doi:10.1126/science.aaf7447 · Cited by 211
Liu, M., Wang, Z., Liu, P., Wang, Z., Yao, H., & Yao, X. (2019) · Science Advances · doi:10.1126/sciadv.aaw5643 · Cited by 209
3D printing of liquid metals as fugitive inks for fabrication of 3D microfluidic channels
Parekh, D. P., Ladd, C., Panich, L., Moussa, K., & Dickey, M. D. (2016) · Lab on a Chip · doi:10.1039/c6lc00198j · Cited by 205
Carlson, A., Wang, S., Elvikis, P., Ferreira, P. M., Huang, Y., & Rogers, J. A. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201201023 · Cited by 175
Reliable microfluidic on-chip incubation of droplets in delay-lines
Frenz, L., Blank, K., Brouzes, E., & Griffiths, A. D. (2009) · Lab Chip · doi:10.1039/b816049j · Cited by 170
A low temperature surface modification assisted method for bonding plastic substrates
Vlachopoulou, M.-E., Tserepi, A., Pavli, P., Argitis, P., Sanopoulou, M., & Misiakos, K. (2009) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/19/1/015007 · Cited by 164
Polymer integration for packaging of implantable sensors
Qin, Y., Howlader, M. M. R., Deen, M. J., Haddara, Y. M., & Selvaganapathy, P. R. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.05.063 · Cited by 163
Electronics with shape actuation for minimally invasive spinal cord stimulation
Woodington, B. J., Curto, V. F., Yu, Y.-L., Martínez-Domínguez, H., Coles, L., Malliaras, G. G., Proctor, C. M., & Barone, D. G. (2021) · Science Advances · doi:10.1126/sciadv.abg7833 · Cited by 75
“Initially, fabrication of the device fluidics was explored using siliconesilicone bonding via O2 plasma activation, a common technique used in silicone fabrication (25, 26), but this option does not enable the device to hold high-enough internal pressures.”
MethodGhasemi Toudeshkchouei, M., Zahedi, P., & Shavandi, A. (2020) · Materials · doi:10.3390/ma13071483 · Cited by 39
“Subsequently, the chip was treated with oxygen-plasma [30] to stick it on the glass and prevent rapid swelling under exposure of solvents like acetone [31].”
Method
Metadata
- Authors
- Eddings, M. A., Johnson, M. A., & Gale, B. K.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2008-04-25
- Volume
- 18
- Issue
- 6
- Pages
- 067001
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2039001850
- Cited by
- 567
- References
- 10
- FWCI
- 18.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.