A novel masking method for high aspect ratio penetrating microelectrode arrays
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
Neural interfaces connect signal processing electronics to the nervous system via implanted microelectrode arrays such as the Utah electrode array (UEA). The penetrating electrodes of the UEA are encapsulated with parylene-C. In order to form active electrode sites, parylene-C must be removed from the electrode tips. Masking the electrodes to selectively de-insulate the tips has been accomplished by poking the electrode through aluminum foil. This mechanical poking process lacks precise control over the length of exposed tips. The non-uniformity in tip exposure can change the electrode impedance across the array, which causes variability in recording and stimulating characteristics. This paper focuses on the development of a fabrication technology to produce uniformly exposed tip lengths, over a range of 30–350 µm. A novel batch-oriented and wafer-scale method to de-insulate the electrode tips of the UEA is presented which uses a photoresist to mask the samples and an oxygen plasma to etch parylene-C. The tip exposure is controlled by varying the spin speed during photoresist coating of the electrode array. At 100 rpm, the non-uniformity of the batch-processed arrays was 14.74 ± 7.49% while in the case of a wafer-scale process it was 3.0 ± 0.2% for 10 × 10 electrodes; this indicates that the wafer-scale process leads to better uniformity in tip exposure. A set of photoresist-based process parameters were also tested to ensure that the electrical and mechanical properties of parylene-C were not compromised by the process.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Campbell, P. K., Jones, K. E., Huber, R. J., Horch, K. W., & Normann, R. A. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.83588 · Cited by 881
Self-citationSelective Stimulation of Cat Sciatic Nerve Using an Array of Varying-Length Microelectrodes
Branner, A., Stein, R. B., & Normann, R. A. (2001) · Journal of Neurophysiology · doi:10.1152/jn.2001.85.4.1585 · Cited by 359
Self-citationSelective Electrical Interfaces with the Nervous System
Rutten, W. L. C. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.020702.153427 · Cited by 276
Endoneural selective stimulating using wire-microelectrode arrays
Smit, J. P. A., Rutten, W. L. C., & Boom, H. B. K. (1999) · IEEE Transactions on Rehabilitation Engineering · doi:10.1109/86.808943 · Cited by 20
Cited by
Szostak, K. M., Grand, L., & Constandinou, T. G. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00665 · Cited by 168
“To address this, masking can be done by piercing a sheet of aluminum foil through needles (Bhandari et al., 2009b).”
BackgroundSensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121
“Although these MEA implants have shown their mettle as chronically viable implants as described in this review, further improvements in their reliability and further control of their critical dimensions on the micrometer scale are expected from improvements to current manufacturing approaches and from innovations in b…”
A wafer-scale etching technique for high aspect ratio implantable MEMS structures
Bhandari, R., Negi, S., Rieth, L., & Solzbacher, F. (2010) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2010.06.011 · Cited by 71
Self-citationChallenges for Large-Scale Cortical Interfaces
Nurmikko, A. (2020) · Neuron · doi:10.1016/j.neuron.2020.10.015 · Cited by 68
A Flexible Microneedle Electrode Array With Solid Silicon Needles
Wang, R., Zhao, W., Wang, W., & Li, Z. (2012) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2012.2203790 · Cited by 55
Metadata
- Authors
- Bhandari, R., Negi, S., Rieth, L., Normann, R. A., & Solzbacher, F.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2009-01-30
- Volume
- 19
- Issue
- 3
- Pages
- 035004
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2085311892
- Cited by
- 39
- References
- 4
- FWCI
- 2.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A novel masking method for high aspect ratio penetrating microelectrode arrays. https://app.cochat.ai/papers/10.1088/0960-1317/19/3/035004
- The paper
- Bhandari, R., Negi, S., Rieth, L., Normann, R. A., & Solzbacher, F. (2009). A novel masking method for high aspect ratio penetrating microelectrode arrays. Journal of Micromechanics and Microengineering. https://doi.org/10.1088/0960-1317/19/3/035004
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.