The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
A single-pixel wireless contact lens display
Abstract
We present the design, construction and in vivo rabbit testing of a wirelessly powered contact lens display. The display consists of an antenna, a 500 × 500 µm2 silicon power harvesting and radio integrated circuit, metal interconnects, insulation layers and a 750 × 750 µm2 transparent sapphire chip containing a custom-designed micro-light emitting diode with peak emission at 475 nm, all integrated onto a contact lens. The display can be powered wirelessly from ∼1 m in free space and ∼2 cm in vivo on a rabbit. The display was tested on live, anesthetized rabbits with no observed adverse effect. In order to extend display capabilities, design and fabrication of micro-Fresnel lenses on a contact lens are presented to move toward a multipixel display that can be worn in the form of a contact lens. Contact lenses with integrated micro-Fresnel lenses were also tested on live rabbits and showed no adverse effect.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“These issues include (i) the use of opaque electronic materials for sensors, integrated circuit (IC) chips, metal antennas, and interconnects that can block users’ vision (15, 17, 18);”
From Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays (2018) · cites this paper as [17]
Citations
Cites
A Method of Measuring Eye Movemnent Using a Scieral Search Coil in a Magnetic Field
Robinson, D. A. (1963) · IEEE Transactions on Bio-medical Electronics · doi:10.1109/tbmel.1963.4322822 · Cited by 2,234
A method of measuring eye movements using a scleral search coil in a magnetic field
Robinson, D. A. (1963) · Medical Entomology and Zoology · Cited by 1,709
A contact lens with embedded sensor for monitoring tear glucose level
Yao, H., Shum, A. J., Cowan, M., Lähdesmäki, I., & Parviz, B. A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2010.12.042 · Cited by 513
Self-citationWireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes
Leonardi, M., Pitchon, E. M., Bertsch, A., Renaud, P., & Mermoud, A. (2009) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.2008.01404.x · Cited by 300
Chu, M. X., Miyajima, K., Takahashi, D., Arakawa, T., Sano, K., Sawada, S.-I., Kudo, H., Iwasaki, Y., Akiyoshi, K., Mochizuki, M., et al. (2011) · Talanta · doi:10.1016/j.talanta.2010.10.055 · Cited by 279
Wearable devices: new ways to manage information
Billinghurst, M., & Starner, T. E. (1999) · Computer · doi:10.1109/2.738305 · Cited by 258
Self-assembled single-crystal silicon circuits on plastic
Stauth, S. A., & Parviz, B. A. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0602893103 · Cited by 215
A RF to DC Voltage Conversion Model for Multi-Stage Rectifiers in UHF RFID Transponders
Barnett, R. E., Liu, J., & Lazar, S. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2008.2010991 · Cited by 207
初, 明. (2011) · Medical Entomology and Zoology · Cited by 157
Badugu, R., Lakowicz, J. R., & Geddes, C. D. (2003) · Analytical Chemistry · doi:10.1021/ac0303721 · Cited by 151
A fully integrated RF-powered contact lens with a single element display
Pandey, J., Liao, Y.-T., Lingley, A., Mirjalili, R., Parviz, B., & Otis, B. P. (2010) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2010.2081989 · Cited by 96
Self-citationHigh-Resolution 128 $times$ 96 Nitride Microdisplay
Choi, H. W., Jeon, C., & Dawson, M. D. (2004) · IEEE Electron Device Letters · doi:10.1109/led.2004.826541 · Cited by 82
Initial Clinical Testing of a Holographic Non-Invasive Contact Lens Glucose Sensor
Domschke, A., March, W. F., Kabilan, S., & Lowe, C. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.89 · Cited by 81
Clinical Trial of a Noninvasive Contact Lens Glucose Sensor
March, W. F., Mueller, A., & Herbrechtsmeier, P. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.782 · Cited by 74
Parviz, B. A. (2009) · IEEE Spectrum · doi:10.1109/mspec.2009.5210042 · Cited by 33
Koch, P. M., & Prasad, R. (2009) · IEEE Spectrum · doi:10.1109/mspec.2009.4808386 · Cited by 24
A Liquid-Crystal Contact-Lens Device for Measurement of Corneal Temperature
Kinn, J. B., & Tell, R. A. (1973) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1973.324238 · Cited by 22
Self-assembled inorganic micro-display on plastic
Saeedi, E., Kim, S. S., & Parviz, B. A. (2007) · Proceedings, IEEE micro electro mechanical systems · doi:10.1109/memsys.2007.4433172 · Cited by 18
Experimental Implantation and Long-term Testing of an Intraocular Vision Aid in Rabbits
Szurman, P. (2005) · Archives of Ophthalmology · doi:10.1001/archopht.123.7.964 · Cited by 14
Experimental Implantation and long–term testing of an Intraocular Vision Aid in rabbits
Warga, M., Szurman, P., Grisanti, S., Ziemssen, F., Kaczmarek, R. T., & Bartz-Schmidt, K. U. (2004) · Investigative Ophthalmology & Visual Science · Cited by 11
Possibilities for continuous glucose monitoring by a functional contact lens
Lähdesmäki, I., Shum, A. J., & Parviz, B. A. (2010) · IEEE Instrumentation & Measurement Magazine · doi:10.1109/mim.2010.5475161 · Cited by 10
Kim, K. Y., Lee, S. Y., & Kim, H. C. (2005) · doi:10.1109/iembs.2004.1403664 · Cited by 9
Experimental Implantation and Long-term Testing of an Intraocular Vision Aid in Rabbits
Liu, D. T. L. (2006) · Archives of Ophthalmology · doi:10.1001/archopht.124.4.609-b · Cited by 5
III-V nitride-based LEDs and lasers: Current status and future opportunities
Nakamura, S. (2002) · Technical digest - International Electron Devices Meeting/Technical digest · doi:10.1109/iedm.2000.904247 · Cited by 5
Contact lens oximetry: a valid concept?
Scott, V. (1996) · doi:10.1049/ic:19960777 · Cited by 2
Research works printed but not linked: 8
- Kim K Lee S Kim H, 2004, IEMBS ’04. 26th Annual Inter. Conf. of the IEEE, 1, 2287
- Scott V Tarassenko L Glynn C Hill A, 1996, Pulse Oximetry: A Critical Appraisal, IEE Colloquium (3 January–3 March)
- Phillips A J, 2007, Contact Lenses, 218
- Saeedi E Kim S Parviz B A, 2007, IEEE 20th Int. Conf. on MEMS, 755
- Nakamura S, 2002, Electron Devices Meeting, 2000. IEDM Technical Digest. International, 9
- Ahlbom A, 1998, Health Phys., 74, 494
- Swerdlow A, 2010, Exposure to High Frequency Electromagnetic Fields, Biological Effects and Health Consequences (100 kHz–300 GHz), 208
- Sweeney D F, 2007, Contact Lenses, 273
Cited by
Sorted by citations
An optoelectronic framework enabled by low-dimensional phase-change films
Hosseini, P., Wright, C. D., & Bhaskaran, H. (2014) · Nature · doi:10.1038/nature13487 · Cited by 762
Soft, smart contact lenses with integrations of wireless circuits, glucose sensors, and displays
Park, J., Kim, J., Kim, S.-Y., Cheong, W. H., Jang, J., Park, Y.-G., Na, K., Kim, Y.-T., Heo, J. H., Lee, C. Y., et al. (2018) · Science Advances · doi:10.1126/sciadv.aap9841 · Cited by 671
Lee, M., Lee, K., Kim, S.-Y., Lee, H., Park, J., Kwang-hyuk, C., Kim, H.-K., Kim, D.-G., Lee, D.-Y., Nam, S., et al. (2013) · Nano Letters · doi:10.1021/nl401070p · Cited by 673
An electric-eel-inspired soft power source from stacked hydrogels
Schroeder, T. B. H., Guha, A., Lamoureux, A., VanRenterghem, G., Sept, D., Shtein, M., Yang, J., & Mayer, M. (2017) · Nature · doi:10.1038/nature24670 · Cited by 591
Billinghurst, M., Clark, A., & Lee, G. (2015) · now publishers, Inc. eBooks · doi:10.1561/9781601989215 · Cited by 539
Metadata
- Authors
- Lingley, A. R., Ali, M., Liao, Y., Mirjalili, R., Klonner, M., Sopanen, M., Suihkonen, S., Shen, T., Otis, B. P., Lipsanen, H., & Parviz, B. A.
- Affiliations
- University of Washington (US)
- Aalto University (FI)
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2011-11-22
- Volume
- 21
- Issue
- 12
- Pages
- 125014
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2050813770
- Cited by
- 148
- References
- 26
- Citations by year
- 2026: 4 · 2025: 6 · 2024: 7 · 2023: 6 · 2022: 14 · 2021: 15 · 2020: 9 · 2019: 11 · 2018: 10 · 2017: 8 · 2016: 10 · 2015: 10 · 2014: 12 · 2013: 14 · 2012: 12
- FWCI
- 8.50
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Micromechanics and Microengineering (publishedVersion)
- Funders
- Agilent Technologies
- Defense Advanced Research Projects Agency
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Wireless Power Transfer Systems
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
- Keywords
- wireless power transfer, micro-LEDs, in vivo evaluation, rabbit eye, wearable displays
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review