Polymer-based flexible capacitive sensor for three-axial force measurements
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
We have developed a flexible-substrate-based three-axial force sensor, composed of finger-shaped electrode capacitors, whose operation is based on the measurement of a capacitance change induced upon applying a three-axial load. The electrode design supports high sensitivity to shear forces. An overall flexibility of the sensor and elasticity of the capacitor's dielectric is obtained by integrating three polymers in the sensor's technology process, namely polyimide, parylene-C, and polydimethylsiloxane, combined with standard metallization processes. We have theoretically modeled the sensor's capacitance and its three-axial force sensitivity. The unit capacitors have static capacitances in the range of 20 pF. The electro-mechanical characterization of the capacitors reveals in the normal direction a sensitivity S z = 0.024 kPa −1 for pressures <10 kPa, whereas for higher pressures the measured sensitivity S z = 6.6 × 10 −4 kPa −1 . Typical measured shear force sensitivity S x = 2.8 × 10 −4 kPa −1 . These values give our transducer high potential for use in skin-like sensing applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
Reach and grasp by people with tetraplegia using a neurally controlled robotic arm
Hochberg, L. R., Bacher, D., Jarosiewicz, B., Masse, N. Y., Simeral, J. D., Vogel, J., Haddadin, S., Liu, J., Cash, S. S., van der Smagt, P., et al. (2012) · Nature · doi:10.1038/nature11076 · Cited by 2,719
Someya, T., Sekitani, T., Iba, S., Kato, Y., Kawaguchi, H., & Sakurai, T. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401918101 · Cited by 1,921
Soft Robotics: Biological Inspiration, State of the Art, and Future Research
Trivedi, D., Rahn, C. D., Kier, W. M., & Walker, I. D. (2008) · Applied Bionics and Biomechanics · doi:10.1080/11762320802557865 · Cited by 1,708 · cited 1×
“Moreover, the tactile interaction between a human and a robot should pass via a soft medium for future human-friendly robotics [9, 10], which requires a wide-area flexible sensory organ as synthetic skin.”
BackgroundJohansson, R. S., & Westling, G. (1984) · Experimental Brain Research · doi:10.1007/bf00237997 · Cited by 1,703
Someya, T., Kato, Y., Sekitani, T., Iba, S., Noguchi, Y., Murase, Y., Kawaguchi, H., & Sakurai, T. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0502392102 · Cited by 1,389 · cited 1×
“Technologies of nanowire-based field-effect transistors [11], organic field-effect transistors [12–15] integrated with temperature sensing [14], or thin-film transistors [15] show promising concepts, but they address the detection of only uniaxial pressure, normal to the sensor.”
BackgroundNanowire active-matrix circuitry for low-voltage macroscale artificial skin
Takei, K., Takahashi, T., Ho, J. C., Ko, H., Gillies, A. G., Leu, P. W., Fearing, R. S., & Javey, A. (2010) · Nature Materials · doi:10.1038/nmat2835 · Cited by 1,274
Wada, K., & Shibata, T. (2007) · IEEE Transactions on Robotics · doi:10.1109/tro.2007.906261 · Cited by 583 · cited 1×
“A therapeutic seal-robot calms patients of hospitals and nursing homes [4].”
BackgroundMenz, H. B., Morris, M. E., & Lord, S. R. (2005) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/60.12.1546 · Cited by 520
Albu-Schaffer, A., Eiberger, O., Grebenstein, M., Haddadin, S., Ott, C., Wimbock, T., Wolf, S., & Hirzinger, G. (2008) · IEEE Robotics & Automation Magazine · doi:10.1109/mra.2008.927979 · Cited by 506
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Park, J., Lee, Y., Hong, J., Lee, Y., Ha, M., Jung, Y., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn505953t · Cited by 649
Park, S., Kim, H., Vosgueritchian, M., Cheon, S., Kim, H., Koo, J. H., Kim, T. R., Lee, S., Schwartz, G., Chang, H., et al. (2014) · Advanced Materials · doi:10.1002/adma.201402574 · Cited by 565
Flexible Three‐Axial Force Sensor for Soft and Highly Sensitive Artificial Touch
Viry, L., Levi, A., Totaro, M., Mondini, A., Mattoli, V., Mazzolai, B., & Beccai, L. (2014) · Advanced Materials · doi:10.1002/adma.201305064 · Cited by 480
Recent Progress on Flexible Capacitive Pressure Sensors: From Design and Materials to Applications
Mishra, R. B., El‐Atab, N., Hussain, A. M., & Hussain, M. M. (2021) · Advanced Materials Technologies · doi:10.1002/admt.202001023 · Cited by 433
MoS2‐Based Tactile Sensor for Electronic Skin Applications
Park, M., Park, Y. J., Chen, X., Park, Y., Kim, M., & Ahn, J. (2016) · Advanced Materials · doi:10.1002/adma.201505124 · Cited by 425
Recent Developments for Flexible Pressure Sensors: A Review
Xu, F., Li, X., Shi, Y., Li, L., Wang, W., He, L., & Liu, R. (2018) · Micromachines · doi:10.3390/mi9110580 · Cited by 341
Zhu, M., He, T., & Lee, C. (2020) · Applied Physics Reviews · doi:10.1063/5.0016485 · Cited by 287
Recent Progress in Technologies for Tactile Sensors
Chi, C., Sun, X., Xue, N., Li, T., & Liu, C. (2018) · Sensors · doi:10.3390/s18040948 · Cited by 247
“Reprinted from [59], copyright (2012), with permission from IOP Publishing.”
BackgroundMethodInfluentialSun, X., Sun, J., Li, T., Zheng, S., Wang, C., Tan, W., Zhang, J., Liu, C., Ma, T., Qi, Z., et al. (2019) · Nano-Micro Letters · doi:10.1007/s40820-019-0288-7 · Cited by 229
“A variety of flexible materials such as polyethylene (PE) [12], polydimethylsiloxane (PDMS) [13, 14], polyurethane (PU) [15] and polyimide (PI) [16] have been applied to tactile sensors, and the operational principles of tactile sensors mainly include piezoresistive [17–19], capacitive [20], piezoelectric [21] and opt…”
BackgroundLow-cost flexible pressure sensor based on dielectric elastomer film with micro-pores
Lee, B.-Y., Kim, J., Kim, H., Kim, C., & Lee, S.-D. (2016) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2016.01.037 · Cited by 212
Liang, G., Wang, Y., Mei, D., Xi, K., & Chen, Z. (2015) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2015.2418095 · Cited by 187
“Instead of using a PDMS bump, upper and lower comb-shaped electrodes, which constitute four capacitors, have been utilized in the capacitive sensor unit [14], [15].”
Method
Metadata
- Authors
- Dobrzynska, J. A., & Gijs, M. A. M.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2012-11-30
- Volume
- 23
- Issue
- 1
- Pages
- 015009
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2089910578
- Cited by
- 170
- References
- 33
- FWCI
- 5.93
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.