Restoration of grasp following paralysis through brain-controlled stimulation of muscles
Open accessAbstract
Patients with spinal cord injury lack the connections between brain and spinal cord circuits that are essential for voluntary movement. Clinical systems that achieve muscle contraction through functional electrical stimulation (FES) have proven to be effective in allowing patients with tetraplegia to regain control of hand movements and to achieve a greater measure of independence in daily activities. In existing clinical systems, the patient uses residual proximal limb movements to trigger pre-programmed stimulation that causes the paralysed muscles to contract, allowing use of one or two basic grasps. Instead, we have developed an FES system in primates that is controlled by recordings made from microelectrodes permanently implanted in the brain. We simulated some of the effects of the paralysis caused by C5 or C6 spinal cord injury by injecting rhesus monkeys with a local anaesthetic to block the median and ulnar nerves at the elbow. Then, using recordings from approximately 100 neurons in the motor cortex, we predicted the intended activity of several of the paralysed muscles, and used these predictions to control the intensity of stimulation of the same muscles. This process essentially bypassed the spinal cord, restoring to the monkeys voluntary control of their paralysed muscles. This achievement is a major advance towards similar restoration of hand function in human patients through brain-controlled FES. We anticipate that in human patients, this neuroprosthesis would allow much more flexible and dexterous use of the hand than is possible with existing FES systems.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
CNS-based neuroprostheses, or brain-machine interfaces, decode neural electrical activity to control robotic limbs or to stimulate muscles for restoring limb function.
“CNS-based neuroprostheses, or brain–machine interfaces (BMIs), are systems whereby neural electrical activities are decoded and used to control robotic limbs [76, 89, 105] or to stimulate muscles for restoring limb function [35].”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [35]
All reported BMI experiments with human patients require the subject to be tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.
“Currently, all reported BMI experiments with human patients [26, 35, 57, 58, 150] require the subjects tethered percutaneously to a bench-top computer for neural signal acquisition and decoding.”
From Implantable neurotechnologies: a review of integrated circuit neural amplifiers (2016) · cites this paper as [35]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Targeting Recovery: Priorities of the Spinal Cord-Injured Population
Anderson, K. D. (2004) · Journal of Neurotrauma · doi:10.1089/neu.2004.21.1371 · Cited by 2,094 · see citing works
McDonald, J. W., & Sadowsky, C. L. (2002) · The Lancet · doi:10.1016/s0140-6736(02)07603-1 · Cited by 1,807 · see citing works
Learning to control a brain–machine interface for reaching and grasping by primates
Carmena, J. M., Lebedev, M. A., Crist, R. E., O'Doherty, J. E., Santucci, D. M., Dimitrov, D. F., Patil, P. G., Henriquez, C. S., & Nicolelis, M. A. L. (2003) · PLoS Biology · doi:10.1371/journal.pbio.0000042 · Cited by 1,761 · see citing works
Relation of pyramidal tract activity to force exerted during voluntary movement.
Evarts, E. V. (1968) · Journal of Neurophysiology · doi:10.1152/jn.1968.31.1.14 · Cited by 1,258 · see citing works
Direct control of paralysed muscles by cortical neurons
Moritz, C. T., Perlmutter, S. I., & Fetz, E. E. (2008) · Nature · doi:10.1038/nature07418 · Cited by 602 · see citing works
Spasticity after spinal cord injury
Adams, M. M., & Hicks, A. L. (2005) · Spinal Cord · doi:10.1038/sj.sc.3101757 · Cited by 517 · see citing works
Motor and sensory recovery following incomplete tetraplegia
Waters, R. L., Adkins, R. H., Yakura, J. S., & Sie, I. H. (1994) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/0003-9993(94)90034-5 · Cited by 438 · see citing works
Predicting Measures of Motor Performance from Multiple Cortical Spike Trains
Humphrey, D. R., Schmidt, E. M., & Thompson, W. (1970) · Science · doi:10.1126/science.170.3959.758 · Cited by 372 · see citing works
Peckham, P. H., Keith, M. W., Kilgore, K. L., Grill, J. H., Wuolle, K. S., Thrope, G. B., Gorman, P., Hobby, J., Mulcahey, M. J., Carroll, S., et al. (2001) · Archives of Physical Medicine and Rehabilitation · doi:10.1053/apmr.2001.25910 · Cited by 319 · see citing works
Implantable functional neuromuscular stimulation in the tetraplegic hand
Keith, M. W., Peckham, P. H., Thrope, G. B., Stroh, K. C., Smith, B., Buckett, J. R., Kilgore, K. L., & Jatich, J. W. (1989) · The Journal Of Hand Surgery · doi:10.1016/s0363-5023(89)80017-6 · Cited by 212 · see citing works
An Implanted Upper-Extremity Neuroprosthesis. Follow-up of Five Patients*
KILGORE, K. L., PECKHAM, P. H., KEITH, M. W., THROPE, G. B., WUOLLE, K. S., BRYDEN, A. M., & HART, R. L. (1997) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199704000-00008 · Cited by 192 · see citing works
Popović, M. R., Popović, D. B., & Keller, T. (2002) · Neurological Research · doi:10.1179/016164102101200311 · Cited by 155 · see citing works
Pohlmeyer, E. A., Oby, E. R., Perreault, E. J., Solla, S. A., Kilgore, K. L., Kirsch, R. F., & Miller, L. E. (2009) · PLoS ONE · doi:10.1371/journal.pone.0005924 · Cited by 137 · see citing works
Self-citationPrediction of upper limb muscle activity from motor cortical discharge during reaching
Pohlmeyer, E. A., Solla, S. A., Perreault, E. J., & Miller, L. E. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/4/003 · Cited by 118 · see citing works
Self-citationKern, H., Hofer, C., Mödlin, M., Forstner, C., Raschka‐Högler, D., Mayr, W., & Stöhr, H. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06933.x · Cited by 100 · see citing works
Benefits of FES gait in a spinal cord injured population
Nightingale, E. J., Raymond, J., Middleton, J. W., Crosbie, J., & Davis, G. M. (2007) · Spinal Cord · doi:10.1038/sj.sc.3102101 · Cited by 100 · see citing works
Kinetic Trajectory Decoding Using Motor Cortical Ensembles
Fagg, A. H., Ojakangas, G. W., Miller, L. E., & Hatsopoulos, N. G. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2029313 · Cited by 93 · see citing works
Self-citationAgarwal, S., Triolo, R. J., Kobetic, R., Miller, M. E., Bieri, C., Kukke, S. N., Rohde, L., & Davis, J. A. (2003) · PubMed · Cited by 74 · see citing works
Volitional control of single cortical neurons in a brain–machine interface
Moritz, C. T., & Fetz, E. E. (2011) · Journal of Neural Engineering · doi:10.1088/1741-2560/8/2/025017 · Cited by 70 · see citing works
Cherian, A., Krucoff, M. O., & Miller, L. E. (2011) · Journal of Neurophysiology · doi:10.1152/jn.00553.2010 · Cited by 42 · see citing works
Self-citationGupta, R., & Ashe, J. (2009) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2009.2023290 · Cited by 27 · see citing works
An Implanted Neuroprosthesis for High Tetraplegia
Bryden, A. M., Kilgore, K. L., Kirsch, R. F., Memberg, W. D., Peckham, P. H., & Keith, M. W. (2005) · Topics in Spinal Cord Injury Rehabilitation · doi:10.1310/g9t5-cck9-y0wt-4714 · Cited by 21 · see citing works
Oby, E. R., Éthier, C., Bauman, M. J., Perreault, E. J., Ko, J. H., & Miller, L. E. (2010) · Elsevier eBooks · doi:10.1016/b978-0-12-375027-3.00011-9 · Cited by 12 · see citing works
Self-citationA fully implanted drug delivery system for peripheral nerve blocks in behaving animals
Pohlmeyer, E. A., Jordon, L. R., Kim, P., & Miller, L. E. (2009) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2009.06.006 · Cited by 12 · see citing works
Self-citationA Personal User's View of Functional Electrical Stimulation Cycling
Fitzwater, R. (2002) · Artificial Organs · doi:10.1046/j.1525-1594.2002.06936.x · Cited by 12 · see citing works
Real-Time Control of the Hand by Intracortically Controlled Functional Neuromuscular Stimulation
Pohlmeyer, E. A., Perreault, E. J., Slutzky, M. W., Kilgore, K. L., Kirsch, R. F., Taylor, D. M., & Miller, L. E. (2007) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2007.4428464 · Cited by 12 · see citing works
Self-citation
Flagged first, then by citations
Research works printed but not linked: 2
- [15]Pohlmeyer EA IEEE 10th international conference on rehab robotics 454 458
- [18]Oby ER O'Weiss KG Statistical Signal Processing for Neuroscience and Neurotechnology 369 406 Academic Press, Elsevier 2010
Cited by
Sorted by citations
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848 · see citing works
Restoring cortical control of functional movement in a human with quadriplegia
Bouton, C. E., Shaikhouni, A., Annetta, N. V., Bockbrader, M. A., Friedenberg, D. A., Nielson, D. M., Sharma, G., Sederberg, P. B., Glenn, B. C., Mysiw, W. J., et al. (2016) · Nature · doi:10.1038/nature17435 · Cited by 924 · see citing works
Ajiboye, A. B., Willett, F. R., Young, D. R., Memberg, W. D., Murphy, B. A., Miller, J. P., Walter, B. L., Sweet, J. A., Hoyen, H. A., Keith, M. W., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(17)30601-3 · Cited by 862 · see citing works
Neural Manifolds for the Control of Movement
Gallego, J. Á., Perich, M. G., Miller, L. E., & Solla, S. A. (2017) · Neuron · doi:10.1016/j.neuron.2017.05.025 · Cited by 676 · see citing works
Self-citationBrain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 655 · see citing works
A brain–spine interface alleviating gait deficits after spinal cord injury in primates
Capogrosso, M., Milekovic, T., Borton, D., Wagner, F., Moraud, E. M., Mignardot, J.-B., Buse, N., Gandar, J., Barraud, Q., Xing, D., et al. (2016) · Nature · doi:10.1038/nature20118 · Cited by 635 · see citing works
Pandarinath, C., Nuyujukian, P., Blabe, C. H., Sorice, B. L., Saab, J., Willett, F. R., Hochberg, L. R., Shenoy, K. V., & Henderson, J. M. (2017) · eLife · doi:10.7554/elife.18554 · Cited by 566 · see citing works
“Additionally, Ethier et al ( Ethier et al., 2012 ). showed that monkeys whose grasping movements were prevented using a paralytic agent were still able to reliably generate grasping-related cortical activity, which could then be decoded to activate a functional electrical stimulation system that…”
BackgroundWodlinger, B., Downey, J. E., Tyler-Kabara, E. C., Schwartz, A. B., Boninger, M. L., & Collinger, J. L. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/1/016011 · Cited by 536 · see citing works
Spinal cord repair: advances in biology and technology
Courtine, G., & Sofroniew, M. V. (2019) · Nature Medicine · doi:10.1038/s41591-019-0475-6 · Cited by 508 · see citing works
Long-term stability of cortical population dynamics underlying consistent behavior
Gallego, J. Á., Perich, M. G., Chowdhury, R. H., Solla, S. A., & Miller, L. E. (2020) · Nature Neuroscience · doi:10.1038/s41593-019-0555-4 · Cited by 398 · see citing works
Self-citationRestoring sensorimotor function through intracortical interfaces: progress and looming challenges
Bensmaia, S. J., & Miller, L. E. (2014) · Nature Reviews Neuroscience · doi:10.1038/nrn3724 · Cited by 368 · see citing works
Self-citationJarosiewicz, B., Sarma, A. A., Bacher, D., Masse, N. Y., Simeral, J. D., Sorice, B., Oakley, E. M., Blabe, C., Pandarinath, C., Gilja, V., et al. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aac7328 · Cited by 340 · see citing works
Machine Learning for Neural Decoding
Glaser, J. I., Benjamin, A. S., Chowdhury, R. H., Perich, M. G., Miller, L. E., & Kording, K. P. (2020) · eNeuro · doi:10.1523/eneuro.0506-19.2020 · Cited by 338 · see citing works
Self-citationCortical population activity within a preserved neural manifold underlies multiple motor behaviors
Gallego, J. Á., Perich, M. G., Naufel, S. N., Éthier, C., Solla, S. A., & Miller, L. E. (2018) · Nature Communications · doi:10.1038/s41467-018-06560-z · Cited by 337 · see citing works
Self-citationBrain–machine interfaces in neurorehabilitation of stroke
Soekadar, S. R., Birbaumer, N., Slutzky, M. W., & Cohen, L. G. (2014) · Neurobiology of Disease · doi:10.1016/j.nbd.2014.11.025 · Cited by 335 · see citing works
A polymer optoelectronic interface restores light sensitivity in blind rat retinas
Ghezzi, D., Antognazza, M. R., Maccarone, R., Bellani, S., Lanzarini, E., Martino, N., Mete, M., Pertile, G., Bisti, S., Lanzani, G., et al. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.34 · Cited by 327 · see citing works
Summary of over Fifty Years with Brain-Computer Interfaces—A Review
Kawala‐Sterniuk, A., Browarska, N., Al‐Bakri, A. F., Pelc, M., Zygarlicki, J., Šidiková, M., Martínek, R., & Gorzelańczyk, E. J. (2021) · Brain Sciences · doi:10.3390/brainsci11010043 · Cited by 303 · see citing works
Brain–machine interfaces from motor to mood
Shanechi, M. M. (2019) · Nature Neuroscience · doi:10.1038/s41593-019-0488-y · Cited by 263 · see citing works
Khan, M. A., Das, R., Iversen, H. K., & Puthusserypady, S. K. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103843 · Cited by 262 · see citing works
Neural interfaces for the brain and spinal cord—restoring motor function
Andrew, J. O., & Zimmermann, J. B. (2012) · Nature Reviews Neurology · doi:10.1038/nrneurol.2012.219 · Cited by 254 · see citing works
A Brain-to-Brain Interface for Real-Time Sharing of Sensorimotor Information
Pais-Vieira, M., Lebedev, M., Kunicki, C., Wang, J., & Nicolelis, M. A. L. (2013) · Scientific Reports · doi:10.1038/srep01319 · Cited by 252 · see citing works
Hramov, A. E., Maksimenko, V., & Pisarchik, A. N. (2021) · Physics Reports · doi:10.1016/j.physrep.2021.03.002 · Cited by 218 · see citing works
Wenger, N., Moraud, E. M., Raspopovic, S., Bonizzato, M., DiGiovanna, J., Musienko, P., Morari, M., Micera, S., & Courtine, G. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008325 · Cited by 209 · see citing works
Neuromodulation in the restoration of function after spinal cord injury.
James, N., McMahon, S., Field-Fote, E., & Bradbury, E. (2018) · Lancet Neurology · doi:10.1016/s1474-4422(18)30287-4 · Cited by 140 · see citing works
Krucoff, M. O., Rahimpour, S., Slutzky, M. W., Edgerton, V. R., & Turner, D. A. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00584 · Cited by 188 · see citing works
Artoni, F., Fanciullacci, C., Bertolucci, F., Panarese, A., Makeig, S., Micera, S., & Chisari, C. (2017) · NeuroImage · doi:10.1016/j.neuroimage.2017.07.013 · Cited by 184 · see citing works
Flint, R. D., Wright, Z. A., Scheid, M. R., & Slutzky, M. W. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056005 · Cited by 180 · see citing works
MXene-infused bioelectronic interfaces for multiscale electrophysiology and stimulation
Driscoll, N., Erickson, B. A., Murphy, B. B., Richardson, A. G., Robbins, G., Apollo, N. V., Mentzelopoulos, G., Mathis, T. S., Hantanasirisakul, K., Bagga, P., et al. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abf8629 · Cited by 180 · see citing works
Abiotic-biotic characterization of Pt/Ir microelectrode arrays in chronic implants
Prasad, A., Xue, Q.-S., Dieme, R., Sankar, V., Mayrand, R. C., Nishida, T., Streit, W. J., & Sanchez, J. C. (2014) · Frontiers in Neuroengineering · doi:10.3389/fneng.2014.00002 · Cited by 178 · see citing works
A low-power stretchable neuromorphic nerve with proprioceptive feedback
Lee, Y., Liu, Y., Seo, D.-G., Oh, J. Y., Kim, Y., Li, J., Kang, J., Kim, J., Mun, J., Foudeh, A. M., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00918-x · Cited by 177 · see citing works
Wang, J., Wang, H., Thakor, N. V., & Lee, C. (2019) · ACS Nano · doi:10.1021/acsnano.9b00140 · Cited by 177 · see citing works
Combining Decoder Design and Neural Adaptation in Brain-Machine Interfaces
Shenoy, K. V., & Carmena, J. M. (2014) · Neuron · doi:10.1016/j.neuron.2014.08.038 · Cited by 175 · see citing works
Borton, D., Micera, S., Millán, J. D. R., & Courtine, G. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3005968 · Cited by 171 · see citing works
Bioelectronics for electrical stimulation: materials, devices and biomedical applications
Huang, Y., Yao, K., Zhang, Q., Huang, X., Chen, Z., Zhou, Y., & Yu, X. (2024) · Chemical Society Reviews · doi:10.1039/d4cs00413b · Cited by 166 · see citing works
Wearable Triboelectric Nanogenerators for Therapeutics
Xiao, X., Chen, G., Libanori, A., & Chen, J. (2021) · Trends in Chemistry · doi:10.1016/j.trechm.2021.01.001 · Cited by 151 · see citing works
Brain-controlled modulation of spinal circuits improves recovery from spinal cord injury
Bonizzato, M., Pidpruzhnykova, G., DiGiovanna, J., Shkorbatova, P., Pavlova, N., Micera, S., & Courtine, G. (2018) · Nature Communications · doi:10.1038/s41467-018-05282-6 · Cited by 149 · see citing works
Teaching brain-machine interfaces as an alternative paradigm to neuroprosthetics control
Iturrate, I., Chavarriaga, R., Montesano, L., Minguez, J., & Millán, J. D. R. (2015) · Scientific Reports · doi:10.1038/srep13893 · Cited by 149 · see citing works
Implantable intracortical microelectrodes: reviewing the present with a focus on the future
Wang, Y., Yang, X., Zhang, X., Wang, Y., & Pei, W. (2023) · Microsystems & Nanoengineering · doi:10.1038/s41378-022-00451-6 · Cited by 145 · see citing works
Ortiz-Catalan, M., Brånemark, R., Håkansson, B., & Delbeke, J. (2012) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-11-33 · Cited by 144 · see citing works
Wearable and Implantable Electroceuticals for Therapeutic Electrostimulations
Long, Y., Li, J., Yang, F., Wang, J., & Wang, X. (2021) · Advanced Science · doi:10.1002/advs.202004023 · Cited by 139 · see citing works
Wang, J., Wang, H., He, T., He, B., Thakor, N. V., & Lee, C. (2019) · Advanced Science · doi:10.1002/advs.201900149 · Cited by 137 · see citing works
Stavisky, S. D., Kao, J. C., Nuyujukian, P., Ryu, S. I., & Shenoy, K. V. (2015) · Journal of Neural Engineering · doi:10.1088/1741-2560/12/3/036009 · Cited by 136 · see citing works
Synergy-Based FES for Post-Stroke Rehabilitation of Upper-Limb Motor Functions
Niu, C. M., Bao, Y., Zhuang, C., Li, S., Wang, T., Cui, L., Xie, Q., & Lan, N. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2891004 · Cited by 133 · see citing works
Brain–Computer Interface after Nervous System Injury
Burns, A., Adeli, H., & Buford, J. A. (2014) · The Neuroscientist · doi:10.1177/1073858414549015 · Cited by 131 · see citing works
Translating the Brain-Machine Interface
Thakor, N. V. (2013) · Science Translational Medicine · doi:10.1126/scitranslmed.3007303 · Cited by 128 · see citing works
Preparatory activity and the expansive null-space
Churchland, M. M., & Shenoy, K. V. (2024) · Nature reviews. Neuroscience · doi:10.1038/s41583-024-00796-z · Cited by 126 · see citing works
Brain-Machine Interfaces beyond Neuroprosthetics
Moxon, K. A., & Foffani, G. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.036 · Cited by 125 · see citing works
Configuration of electrical spinal cord stimulation through real-time processing of gait kinematics
Capogrosso, M., Wagner, F. B., Gandar, J., Moraud, E. M., Wenger, N., Milekovic, T., Shkorbatova, P. Y., Pavlova, N., Евгеньевич, М. П., Bézard, E., et al. (2018) · Nature Protocols · doi:10.1038/s41596-018-0030-9 · Cited by 123 · see citing works
Rapid control and feedback rates enhance neuroprosthetic control
Shanechi, M. M., Orsborn, A. L., Moorman, H. G., Gowda, S., Dangi, S., & Carmena, J. M. (2017) · Nature Communications · doi:10.1038/ncomms13825 · Cited by 122 · see citing works
Sensors and Decoding for Intracortical Brain Computer Interfaces
Homer, M. L., Nurmikko, A. V., Donoghue, J. P., & Hochberg, L. R. (2013) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-071910-124640 · Cited by 121 · see citing works
Decoding and perturbing decision states in real time
Peixoto, D., Verhein, J. R., Kiani, R., Kao, J. C., Nuyujukian, P., Chandrasekaran, C., Brown, J., Fong, S., Ryu, S. I., Shenoy, K. V., et al. (2021) · Nature · doi:10.1038/s41586-020-03181-9 · Cited by 120 · see citing works
Advances in Neuroprosthetic Learning and Control
Carmena, J. M. (2013) · PLoS Biology · doi:10.1371/journal.pbio.1001561 · Cited by 117 · see citing works
Graphene oxide doped conducting polymer nanocomposite film for electrode-tissue interface
Tian, H., Liu, J., Wei, D., Kang, X., Zhang, C., Du, J., Yang, B. T., Chen, X., Zhu, H., NuLi, Y., et al. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2013.11.058 · Cited by 115 · see citing works
Shanechi, M. M., Orsborn, A. L., & Carmena, J. M. (2016) · PLoS Computational Biology · doi:10.1371/journal.pcbi.1004730 · Cited by 114 · see citing works
Nason, S. R., Vaskov, A. K., Willsey, M. S., Welle, E. J., An, H., Vu, P. P., Bullard, A. J., Nu, C. S., Kao, J. C., Shenoy, K. V., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0591-0 · Cited by 113 · see citing works
Brain-machine interfaces: an overview.
Lebedev, M. (2014) · Translational Neuroscience · doi:10.2478/s13380-014-0212-z · Cited by 112 · see citing works
Perceiving invisible light through a somatosensory cortical prosthesis
Thomson, E. E., Carra, R. B., & Nicolelis, M. A. L. (2013) · Nature Communications · doi:10.1038/ncomms2497 · Cited by 111 · see citing works
Liu, X., Zhang, M., Richardson, A. G., Lucas, T. H., & der Spiegel, J. V. (2016) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2016.2622738 · Cited by 109 · see citing works
Barra, B., Conti, S., Perich, M. G., Zhuang, K., Schiavone, G., Fallegger, F., Galan, K., James, N. D., Barraud, Q., Delacombaz, M., et al. (2022) · Nature Neuroscience · doi:10.1038/s41593-022-01106-5 · Cited by 109 · see citing works
Mind Reading and Writing: The Future of Neurotechnology
Roelfsema, P. R., Denys, D., & Klink, P. C. (2018) · Trends in Cognitive Sciences · doi:10.1016/j.tics.2018.04.001 · Cited by 107 · see citing works
Jarosiewicz, B., Masse, N. Y., Bacher, D., Cash, S. S., Eskandar, E. N., Friehs, G. M., Donoghue, J. P., & Hochberg, L. R. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046012 · Cited by 106 · see citing works
Interfaces with the Peripheral Nerve for the Control of Neuroprostheses
del Valle, J., & Navarro, X. (2013) · International Review of Neurobiology · doi:10.1016/b978-0-12-420045-6.00002-x · Cited by 105 · see citing works
Nishimura, Y., Perlmutter, S. I., & Fetz, E. E. (2013) · Frontiers in Neural Circuits · doi:10.3389/fncir.2013.00057 · Cited by 105 · see citing works
Design and analysis of closed-loop decoder adaptation algorithms for brain-machine interfaces
Dangi, S., Orsborn, A. L., Moorman, H. G., & Carmena, J. M. (2013) · Neural Computation · doi:10.1162/neco_a_00460 · Cited by 103 · see citing works
Latent Factors and Dynamics in Motor Cortex and Their Application to Brain–Machine Interfaces
Pandarinath, C., Ames, K. C., Russo, A. A., Farshchian, A., Miller, L. E., Dyer, E. L., & Kao, J. C. (2018) · The Journal of Neuroscience · doi:10.1523/jneurosci.1669-18.2018 · Cited by 103 · see citing works
Self-citationA unifying model of concurrent spatial and temporal modularity in muscle activity
Delis, I., Panzeri, S., Pozzo, T., & Berret, B. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00245.2013 · Cited by 103 · see citing works
Review: Human Intracortical Recording and Neural Decoding for Brain–Computer Interfaces
Brandman, D. M., Cash, S. S., & Hochberg, L. R. (2017) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2017.2677443 · Cited by 102 · see citing works
Interfacing the Somatosensory System to Restore Touch and Proprioception: Essential Considerations
Weber, D. J., Friesen, R., & Miller, L. E. (2012) · Journal of Motor Behavior · doi:10.1080/00222895.2012.735283 · Cited by 98 · see citing works
Self-citationThe Smartest Materials: The Future of Nanoelectronics in Medicine
Cohen‐Karni, T., Langer, R., & Kohane, D. S. (2012) · ACS Nano · doi:10.1021/nn302915s · Cited by 95 · see citing works
Flint, R. D., Scheid, M. R., Wright, Z. A., Solla, S. A., & Slutzky, M. W. (2016) · Journal of Neuroscience · doi:10.1523/jneurosci.2339-15.2016 · Cited by 93 · see citing works
Recent development of implantable and flexible nerve electrodes
Shi, Y., Liu, R., He, L. M., Feng, H., Li, Y., & Li, Z. (2020) · Smart Materials in Medicine · doi:10.1016/j.smaim.2020.08.002 · Cited by 90 · see citing works
Closed-loop control of spinal cord stimulation to restore hand function after paralysis
Zimmermann, J. B., & Andrew, J. O. (2014) · Frontiers in Neuroscience · doi:10.3389/fnins.2014.00087 · Cited by 88 · see citing works
Cui, Y., Khan, S. U., Deng, Y., Zhao, M., & Hou, M. (2020) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2020.142170 · Cited by 87 · see citing works
Neuroprosthetic technology for individuals with spinal cord injury
Collinger, J. L., Foldes, S. T., Bruns, T. M., Wodlinger, B., Gaunt, R. A., & Weber, D. J. (2013) · Journal of Spinal Cord Medicine · doi:10.1179/2045772313y.0000000128 · Cited by 87 · see citing works
The Emergence of Single Neurons in Clinical Neurology
Cash, S. S., & Hochberg, L. R. (2015) · Neuron · doi:10.1016/j.neuron.2015.03.058 · Cited by 86 · see citing works
Brain-Machine Interfaces: Powerful Tools for Clinical Treatment and Neuroscientific Investigations
Slutzky, M. W. (2018) · The Neuroscientist · doi:10.1177/1073858418775355 · Cited by 84 · see citing works
Deep learning approaches for neural decoding across architectures and recording modalities
Livezey, J. A., & Glaser, J. I. (2020) · Briefings in Bioinformatics · doi:10.1093/bib/bbaa355 · Cited by 84 · see citing works
Implantable neurotechnologies: a review of integrated circuit neural amplifiers
Ng, K. A., Greenwald, E., Xu, Y. P., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1431-3 · Cited by 83 · see citing works
Area 2 of primary somatosensory cortex encodes kinematics of the whole arm
Chowdhury, R. H., Glaser, J. I., & Miller, L. E. (2020) · eLife · doi:10.7554/elife.48198 · Cited by 82 · see citing works
Self-citationBrain-controlled neuromuscular stimulation to drive neural plasticity and functional recovery
Éthier, C., Gallego, J. Á., & Miller, L. E. (2015) · Current Opinion in Neurobiology · doi:10.1016/j.conb.2015.03.007 · Cited by 82 · see citing works
Self-citationNeuroprosthetic-enabled control of graded arm muscle contraction in a paralyzed human
Friedenberg, D. A., Schwemmer, M. A., Landgraf, A. J., Annetta, N. V., Bockbrader, M. A., Bouton, C. E., Zhang, M., Rezai, A. R., Mysiw, W. J., Bresler, H. S., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-08120-9 · Cited by 80 · see citing works
Soft human–machine interfaces: design, sensing and stimulation
Dong, W., Wang, Y., Zhou, Y., Bai, Y., Ju, Z., Guo, J., Gu, G., Bai, K., Ouyang, G., Chen, S., et al. (2018) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-018-0060-z · Cited by 80 · see citing works
Decoding Local Field Potentials for Neural Interfaces
Andrew, J. O., & Hall, T. M. (2016) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2016.2612001 · Cited by 77 · see citing works
The science and engineering behind sensitized brain-controlled bionic hands
Pandarinath, C., & Bensmaı̈a, S. J. (2021) · Physiological Reviews · doi:10.1152/physrev.00034.2020 · Cited by 76 · see citing works
Design and validation of a real-time spiking-neural-network decoder for brain–machine interfaces
Dethier, J., Nuyujukian, P., Ryu, S. I., Shenoy, K. V., & Boahen, K. A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/3/036008 · Cited by 75 · see citing works
Brain control of bimanual movement enabled by recurrent neural networks
Deo, D. R., Willett, F. R., Avansino, D. T., Hochberg, L. R., Henderson, J. M., & Shenoy, K. V. (2024) · Scientific Reports · doi:10.1038/s41598-024-51617-3 · Cited by 73 · see citing works
Stabilizing brain-computer interfaces through alignment of latent dynamics
Karpowicz, B. M., Ali, Y. H., Wimalasena, L. N., Sedler, A. R., Keshtkaran, M. R., Bodkin, K. L., Ma, X., Rubin, D. B., Williams, Z. M., Cash, S. S., et al. (2025) · Nature Communications · doi:10.1038/s41467-025-59652-y · Cited by 73 · see citing works
Self-citationExtracting kinetic information from human motor cortical signals
Flint, R. D., Wang, P. T., Wright, Z. A., King, C., Krucoff, M. O., Schuele, S., Rosenow, J. M., Hsu, F. P. K., Liu, C. Y., Lin, J. J., et al. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2014.07.049 · Cited by 72 · see citing works
Implantable Self‐Powered Systems for Electrical Stimulation Medical Devices
Cui, X. J., Wu, L., Zhang, C., & Li, Z. (2024) · Advanced Science · doi:10.1002/advs.202412044 · Cited by 71 · see citing works
Intrafascicular stimulation of monkey arm nerves evokes coordinated grasp and sensory responses
Ledbetter, N. M., Ethier, C., Oby, E. R., Hiatt, S. D., Wilder, A. M., Ko, J. H., Agnew, S. P., Miller, L. E., & Clark, G. A. (2013) · Journal of Neurophysiology · doi:10.1152/jn.00688.2011 · Cited by 69 · see citing works
Self-citationThe utility of multichannel local field potentials for brain–machine interfaces
Hwang, E. J., & Andersen, R. A. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/4/046005 · Cited by 69 · see citing works
Collinger, J. L., Kryger, M. A., Barbara, R., Betler, T., Bowsher, K., Brown, E. H. P., Clanton, S. T., Degenhart, A. D., Foldes, S. T., Gaunt, R. A., et al. (2014) · Clinical and Translational Science · doi:10.1111/cts.12086 · Cited by 68 · see citing works
Intention estimation in brain–machine interfaces
Fan, J. M., Nuyujukian, P., Kao, J. C., Chestek, C. A., Ryu, S. I., & Shenoy, K. V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/1/016004 · Cited by 68 · see citing works
Alam, M., Rodrigues, W., Pham, B., & Thakor, N. V. (2016) · Brain Research · doi:10.1016/j.brainres.2016.05.039 · Cited by 68 · see citing works
Dendritic calcium signals in rhesus macaque motor cortex drive an optical brain-computer interface
Trautmann, E. M., O’Shea, D. J., Sun, X., Marshel, J. H., Crow, A., Hsueh, B., Vesuna, S. S., Cofer, L. B., Bohner, G., Allen, W., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-23884-5 · Cited by 67 · see citing works
The PennBMBI: Design of a General Purpose Wireless Brain-Machine-Brain Interface System
Liu, X., Zhang, M., Subei, B., Richardson, A. G., Lucas, T. H., & der Spiegel, J. V. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2015.2392555 · Cited by 66 · see citing works
Performance sustaining intracortical neural prostheses
Nuyujukian, P., Kao, J. C., Fan, J. M., Stavisky, S. D., Ryu, S. I., & Shenoy, K. V. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/066003 · Cited by 66 · see citing works
Neurostimulation for Stroke Rehabilitation
Ting, W. K., Fadul, F. A.-R., Fecteau, S., & Éthier, C. (2021) · Frontiers in Neuroscience · doi:10.3389/fnins.2021.649459 · Cited by 64 · see citing works
Brain-Computer-Spinal Interface Restores Upper Limb Function After Spinal Cord Injury
Samejima, S., Khorasani, A., Ranganathan, V. N., Nakahara, J., Tolley, N. M., Boissenin, A., Shalchyan, V., Daliri, M. R., Smith, J. R., & Moritz, C. T. (2021) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2021.3090269 · Cited by 64 · see citing works
Motor cortical activity changes during neuroprosthetic-controlled object interaction
Downey, J. E., Brane, L., Gaunt, R. A., Tyler-Kabara, E. C., Boninger, M. L., & Collinger, J. L. (2017) · Scientific Reports · doi:10.1038/s41598-017-17222-3 · Cited by 63 · see citing works
- Authors
- Ethier, C., Oby, E. R., Bauman, M. J., & Miller, L. E.
- Affiliations
- Northwestern University (US)
- University of Pittsburgh (US)
- Corresponding author
- Miller, L. E.
- Venue
- Nature
- Published
- 2012-04-18
- Volume
- 485
- Issue
- 7398
- Pages
- 368-371
- ISSN
- 0028-0836 (ISSN-L)
- 1476-4687
- PMC
- PMC3358575
- OpenAlex
- W1988067967
- Cited by
- 485
- References
- 26
- Citations by year
- 2026: 9 · 2025: 22 · 2024: 24 · 2023: 27 · 2022: 24 · 2021: 33 · 2020: 29 · 2019: 28 · 2018: 42 · 2017: 44 · 2016: 46 · 2015: 38 · 2014: 55 · 2013: 46 · 2012: 18
- FWCI
- 20.69
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Licence
- www.springer.com/tdm (tdm)
- Locations
- Nature (publishedVersion)
- PubMed (publishedVersion)
- PubMed Central (acceptedVersion)
- RePEc: Research Papers in Economics (submittedVersion)
- Funders
- National Institute of Neurological Disorders and Stroke (R01NS053603, F31NS071737, #NS053603)
- Topics
- Life Sciences › Neuroscience › Cellular and Molecular Neuroscience › Neuroscience and Neural Engineering
- Health Sciences › Medicine › Pathology and Forensic Medicine › Spinal Cord Injury Research
- Life Sciences › Neuroscience › Cognitive Neuroscience › EEG and Brain-Computer Interfaces
- Keywords
- brain-computer interface, functional electrical stimulation, paralysis, spinal cord injury, motor cortex, neural prostheses, hand grasping, rhesus monkeys, tetraplegia, hand function recovery, prosthetic hand control
- MeSH terms
- Animals, Electric Stimulation, Electrodes, Implanted, Hand, Macaca mulatta, Microelectrodes, Motor Cortex, Movement, Muscles, Nerve Block, Paralysis, Quadriplegia, Spinal Cord Injuries, Hand Strength, Prostheses and Implants
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review