SU-8: a low-cost negative resist for MEMS
Open accessThe DOI matches its Crossref record.
Abstract
This paper describes the characterization of a home-made negative photoresist developed by IBM. This resist, called SU-8, can be produced with commercially available materials. Three blends were prepared for this article and some of its optical and mechanical properties are presented. One of its numerous advantages is the broad range of thicknesses which can be obtained in one spin: from 750 nm to with a conventional spin coater. The resist is exposed with a standard UV aligner and has an outstanding aspect ratio near 15 for lines and 10 for trenches. These ratios combined with the electroplating of copper allow the fabrication of highly integrated electromagnetic coils.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Greener Approaches to Organic Synthesis Using Microreactor Technology
Mason, B. P., Price, K. E., Steinbacher, J. L., Bogdan, A. R., & McQuade, D. T. (2007) · Chemical Reviews · doi:10.1021/cr050944c · Cited by 985
Microelectromechanical systems (MEMS): fabrication, design and applications
Judy, J. W. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/6/301 · Cited by 828
An Introduction to Microelectromechanical Systems Engineering
Maluf, N. (2002) · Measurement Science and Technology · doi:10.1088/0957-0233/13/2/701 · Cited by 694
Convery, N., & Gadegaard, N. (2019) · Micro and Nano Engineering · doi:10.1016/j.mne.2019.01.003 · Cited by 602
High-aspect-ratio, ultrathick, negative-tone near-UV photoresist and its applications for MEMS
Lorenz, H., Despont, M., Fahrni, N., Brugger, J., Vettiger, P., & Renaud, P. (1998) · Sensors and Actuators A: Physical · doi:10.1016/s0924-4247(98)80055-1 · Cited by 573
Self-citationVisualizing Graphene Based Sheets by Fluorescence Quenching Microscopy
Kim, J., Cote, L. J., Kim, F., & Huang, J. (2010) · Journal of the American Chemical Society · doi:10.1021/ja906730d · Cited by 526
New materials for micro-scale sensors and actuators
Wilson, S. A., Jourdain, R. P. J., Zhang, Q., Dorey, R. A., Bowen, C. R., Willander, M., Wahab, Q. U., Willander, M., Al-hilli, S. M., Nur, O., et al. (2007) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2007.03.001 · Cited by 514
Verpoorte, E., & De Rooij, N. F. (2003) · Proceedings of the IEEE · doi:10.1109/jproc.2003.813570 · Cited by 503
Lab-on-a-chip devices: How to close and plug the lab?
Temiz, Y., Lovchik, R. D., Kaigala, G. V., & Delamarche, E. (2015) · Microelectronic Engineering · doi:10.1016/j.mee.2014.10.013 · Cited by 475
Recent Developments in Polymer MEMS
Liu, C. (2007) · Advanced Materials · doi:10.1002/adma.200701709 · Cited by 422
Walia, S., Shah, C. M., Gutruf, P., Nili, H., Chowdhury, D. R., Withayachumnankul, W., Bhaskaran, M., & Sriram, S. (2015) · Applied Physics Reviews · doi:10.1063/1.4913751 · Cited by 392
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Xurography: rapid prototyping of microstructures using a cutting plotter
Bartholomeusz, D. A., Boutte, R. W., & Andrade, J. D. (2005) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2005.859087 · Cited by 360
Feng, R., & Farris, R. J. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/13/1/312 · Cited by 359
Surface tension-powered self-assembly of microstructures - The state-of-the-art
Syms, R. R. A., Yeatman, E. M., Bright, V. M., & Whitesides, G. M. (2003) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2003.811724 · Cited by 339
3D printing of functional microrobots
Li, J., & Pumera, M. (2021) · Chemical Society Reviews · doi:10.1039/d0cs01062f · Cited by 303
Heuschkel, M. O., Fejtl, M., Raggenbass, M., Bertrand, D., & Renaud, P. (2002) · Journal of Neuroscience Methods · doi:10.1016/s0165-0270(01)00514-3 · Cited by 291
Self-citationChemical Aspects of Three-Dimensional Photonic Crystals
Moon, J. H., & Yang, S. (2010) · Chemical Reviews · doi:10.1021/cr900080v · Cited by 267
SU‐8 as a structural material for labs‐on‐chips and microelectromechanical systems
Abgrall, P., Conedera, V., Camon, H., Gue, A., & Nguyen, N. (2007) · ELECTROPHORESIS · doi:10.1002/elps.200700333 · Cited by 242
Microfluidic systems with on-line UV detection fabricated in photodefinable epoxy
Jackman, R. J., Floyd, T. M., Ghodssi, R., Schmidt, M. A., & Jensen, K. F. (2001) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/11/3/316 · Cited by 220
Rapid prototyping of microfluidic chips in COC
Steigert, J., Haeberle, S., Brenner, T., Müller, C., Steinert, C. P., Koltay, P., Gottschlich, N., Reinecke, H., Rühe, J., Zengerle, R., et al. (2007) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/17/2/020 · Cited by 194
“The following process parameters are applicable to thicknesses of composite layers of SU-8 2100 [30] and SU-8 2025 [14, 31] up to 300 μm.”
BackgroundMethodMolding of Deep Polydimethylsiloxane Microstructures for Microfluidics and Biological Applications
Folch, A., Ayon, A., Hurtado, O., Schmidt, M. A., & Toner, M. (1999) · Journal of Biomechanical Engineering · doi:10.1115/1.2798038 · Cited by 174
3D microfabrication with inclined/rotated UV lithography
Han, M., Lee, W., Lee, S.-K., & Lee, S. S. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.10.006 · Cited by 172
Self-Assembly of 10-μm-Sized Objects into Ordered Three-Dimensional Arrays
Clark, T. D., Tien, J., Duffy, D. C., Paul, K. E., & Whitesides, G. M. (2001) · Journal of the American Chemical Society · doi:10.1021/ja010634l · Cited by 171
Optically Driven Soft Micro Robotics
Nocentini, S., Parmeggiani, C., Martella, D., & Wiersma, D. S. (2018) · Advanced Optical Materials · doi:10.1002/adom.201800207 · Cited by 170
Keller, S., Blagoi, G., Lillemose, M., Haefliger, D., & Boisen, A. (2008) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/18/12/125020 · Cited by 170
Multidirectional UV Lithography for Complex 3-D MEMS Structures
Yoon, Y.-K., Park, J.-H., & Allen, M. G. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.879669 · Cited by 160
“Very high-aspect-ratio microstructures have been implemented from SU-8 photoresist (PR) using UV or near-UV light sources [4]–[7].”
BackgroundHighly sensitive polymer-based cantilever-sensors for DNA detection
Calleja, M., Nordström, M., Álvarez, M., Tamayo, J., Lechuga, L. M., & Boisen, A. (2005) · Ultramicroscopy · doi:10.1016/j.ultramic.2005.06.039 · Cited by 159
Thinking Small: Progress on Microscale Neurostimulation Technology
Pancrazio, J. J., Deku, F., Ghazavi, A., Stiller, A. M., Rihani, R., Frewin, C. L., Varner, V. D., Gardner, T. J., & Cogan, S. F. (2017) · Neuromodulation: Technology at the Neural Interface · doi:10.1111/ner.12716 · Cited by 60
“Values for moduli of each substrate were taken from published literature: Iridium (24), carbon fiber (25,26), platinum (24), silicon (27), a-SiC (28), gold (29), SU-8 (30), Parylene C (31), nanocomposite (32), and human brain tissue (33).”
Guanxing, Z., Liu, Z., Deng, W., & Zhu, W. (2021) · Journal of Optics · doi:10.1088/2040-8986/abcc52 · Cited by 34
Varying-Length Polymer Microneedle Arrays Fabricated by Droplet Backside Exposure
Kwon, K. Y., Weber, A., & Li, W. (2014) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2014.2352412 · Cited by 23
Metadata
- Authors
- Lorenz, H., Despont, M., Fahrni, N., LaBianca, N., Renaud, P., & Vettiger, P.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 1997-09-01
- Volume
- 7
- Issue
- 3
- Pages
- 121-124
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2082983861
- Cited by
- 979
- References
- 0
- FWCI
- 15.58
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.