The effect of surface-electrode resistance on the performance of ionic polymer-metal composite (IPMC) artificial muscles
Open accessThe DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Reported in this study are the effects of the surface-electrode resistance on the performance of ionic polymer-metal composite (IPMC) artificial muscles. The IPMC artificial muscles manufactured in this study is composed of a perfluorinated ion-exchange membrane, platinum composited by using a chemical processing technique that employs a platinum salt and appropriate reducing agents. Furthermore, the IPMC artificial muscles were optimized for producing improved forces by changing multiple process parameters including the time-dependent concentrations of the salt and reducing agents. However, the analytical results confirmed that the platinum electrode is successfully deposited on the surface of the material where platinum particles stay in a dense form that appears to introduce a significant level of surface-electrode resistance. In order to address this problem, a thin layer of silver (or copper) was electrochemically deposited on top of the platinum electrode to reduce the surface-electrode resistance. Actuation tests were performed for such IPMC artificial muscles under a low voltage. The test results show that the lower surface-electrode resistance generates higher actuation capability in the IPMC artificial muscles. This observation is briefly discussed based on the role that the equivalent circuit for the IPMC plays and a possible electrophoretic cation-transport phenomenon under the influence of an electric field.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of polymer chemistry
(1995) · Choice Reviews Online · doi:10.5860/choice.33-2140 · Cited by 15,218
Physical chemistry of surfaces
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4499 · Cited by 11,648
A polymer gel with electrically driven motility
Osada, Y., Okuzaki, H., & Hori, H. (1992) · Nature · doi:10.1038/355242a0 · Cited by 1,306
Shahinpoor, M., Bar-Cohen, Y., Simpson, J. O., & Smith, J. (1998) · Smart Materials and Structures · doi:10.1088/0964-1726/7/6/001 · Cited by 1,021
Self-citationKUHN, W., HARGITAY, B., KATCHALSKY, A., & EISENBERG, H. (1950) · Nature · doi:10.1038/165514a0 · Cited by 490
Mechanoelectric effects in ionic gels
Gennes, P. G. D., Okumura, K., Shahinpoor, M., & Kim, K. J. (2000) · Europhysics Letters (EPL) · doi:10.1209/epl/i2000-00299-3 · Cited by 333
Self-citationSadeghipour, K., Salomon, R., & Neogi, S. (1992) · Smart Materials and Structures · doi:10.1088/0964-1726/1/2/012 · Cited by 254
Asaka, K., Oguro, K., Nishimura, Y., Mizuhata, M., & Takenaka, H. (1995) · Polymer Journal · doi:10.1295/polymj.27.436 · Cited by 249
Solid polymer electrolyte water electrolysis
TAKENAKA, H., TORIKAI, E., KAWAMI, Y., & WAKABAYASHI, N. (1982) · International Journal of Hydrogen Energy · doi:10.1016/0360-3199(82)90050-7 · Cited by 226
Rapid swelling and deswelling of reversible gels of polymeric acids by ionization
Katchalsky, A. (1949) · Experientia · doi:10.1007/bf02172636 · Cited by 208
Shahinpoor, M. (1992) · Smart Materials and Structures · doi:10.1088/0964-1726/1/1/014 · Cited by 199
Self-citationNew solid polymer electrolyte composites for water electrolysis
Millet, P., Pineri, M., & Durand, R. (1989) · Journal of Applied Electrochemistry · doi:10.1007/bf01062295 · Cited by 176
Micro-Electro-Mechanics of Ionic Polymeric Gels As Electrically Controllable Artificial Muscles
Shahinpoor, M. (1995) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x9500600302 · Cited by 164
Self-citationElectrolytically Activated Contractile Polymer
Hamlen, R. P., Kent, C.-W., & SHAFER, S. N. (1965) · Nature · doi:10.1038/2061149b0 · Cited by 132
In Situ Electrode Formation on a Nafion Membrane by Chemical Platinization
Liu, R., Her, W., & Fedkiw, P. S. (1992) · Journal of The Electrochemical Society · doi:10.1149/1.2069162 · Cited by 130
Kühn, W. (1949) · Cellular and Molecular Life Sciences · doi:10.1007/bf02172635 · Cited by 128
Batteries with Solid Ion Exchange Electrolytes
Grubb, W. T. (1959) · Journal of The Electrochemical Society · doi:10.1149/1.2427329 · Cited by 115
Mosdale, R., Gebel, G., & Pinéri, M. (1996) · Journal of Membrane Science · doi:10.1016/0376-7388(96)00110-x · Cited by 97
Polymer electrolyte actuator with gold electrodes
Oguro, K., Fujiwara, N., Asaka, K., Onishi, K., & Sewa, S. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.349698 · Cited by 97
Electromechanical Transduction with Charged Polyelectrolyte Membranes
Grodzinsky, A. J., & Melcher, J. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324600 · Cited by 51
Preparation of solid polymer electrolyte composites: investigation of the precipitation process
Millet, P., Andolfatto, F., & Durand, R. (1995) · Journal of Applied Electrochemistry · doi:10.1007/bf00262961 · Cited by 40
The Venus Flytrap as a model for a biomimetic material with built-in sensors and actuators
Shahinpoor, M., & Thompson, M. S. (1995) · Materials Science and Engineering C · doi:10.1016/0928-4931(95)00105-0 · Cited by 32
Self-citation
Cited by
Ionic polymer-metal composites: I. Fundamentals
Shahinpoor, M., & Kim, K. J. (2001) · Smart Materials and Structures · doi:10.1088/0964-1726/10/4/327 · Cited by 1,126
Self-citationArtificial Muscle Technology: Physical Principles and Naval Prospects
Madden, J. D. W., Vandesteeg, N. A., Anquetil, P. A., Madden, P. G. A., Takshi, A., Pytel, R. Z., Lafontaine, S. R., Wieringa, P. A., & Hunter, I. W. (2004) · IEEE Journal of Oceanic Engineering · doi:10.1109/joe.2004.833135 · Cited by 1,035
Ionic polymer metal composites: II. Manufacturing techniques
Kim, K. J., & Shahinpoor, M. (2003) · Smart Materials and Structures · doi:10.1088/0964-1726/12/1/308 · Cited by 584
Self-citationNemat-Nasser, S., & Wu, Y. (2003) · Journal of Applied Physics · doi:10.1063/1.1563300 · Cited by 381
Shahinpoor, M., & Kim, K. J. (2004) · Smart Materials and Structures · doi:10.1088/0964-1726/13/6/009 · Cited by 379
Self-citation
Metadata
- Authors
- Shahinpoor, M., & Kim, K. J.
- Venue
- Smart Materials and Structures
- Publisher
- IOP Publishing
- Published
- 2000-08-01
- Volume
- 9
- Issue
- 4
- Pages
- 543-551
- ISSN
- 0964-1726 (ISSN-L)
- 1361-665X
- OpenAlex
- W1980063106
- Cited by
- 283
- References
- 22
- FWCI
- 7.75
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.