The DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Characterization of common carotid artery blood-flow waveforms in normal human subjects
Open accessAbstract
Knowledge of human blood-flow waveforms is required for in vitro investigations and numerical modelling. Parameters of interest include: velocity and flow waveform shapes, inter- and intra-subject variability and frequency content. We characterized the blood-velocity waveforms in the left and right common carotid arteries (CCAs) of 17 normal volunteers (24 to 34 years), analysing 3560 cardiac cycles in total. Instantaneous peak-velocity (Vpeak) measurements were obtained using pulsed-Doppler ultrasound with simultaneous collection of ECG data. An archetypal Vpeak waveform was created using velocity and timing parameters at waveform feature points. We report the following timing (post-R-wave) and peak-velocity parameters: cardiac interbeat interval (T(RR)) = 0.917 s (intra-subject standard deviation = +/- 0.045 s); cycle-averaged peak-velocity (V(CYC)) = 38.8 cm s(-1) (+/-1.5 cm s(-1)); maximum systolic Vpeak = 108.2 cm s(-1) (+/-3.8 cm s(-1)) at 0.152 s (+/-0.008 s); dicrotic notch Vpeak = 19.4 cm s(-1) (+/-2.9 cm s(-1)) at 0.398 s (+/-0.007 s). Frequency components below 12 Hz constituted 95% of the amplitude spectrum. Flow waveforms were computed from Vpeak by analytical solution of Womersley flow conditions (derived mean flow = 6.0 ml s(-1)). We propose that realistic, pseudo-random flow waveform sequences can be generated for experimental studies by varying, from cycle to cycle, only T(RR) and V(CYC) of a single archetypal waveform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brigham, E. O., & Yuen, C. K. (1978) · IEEE Transactions on Systems, Man, and Cybernetics · doi:10.1109/tsmc.1978.4309919 · Cited by 1,038
Hemodynamics and atherosclerosis. Insights and perspectives gained from studies of human arteries.
Glagov, S., Zarins, C. K., Giddens, D. P., & Ku, D. N. (1988) · PubMed · Cited by 1,029
Phase contrast cine magnetic resonance imaging.
Pelc, N. J., Herfkens, R. J., Shimakawa, A. S., & Enzmann, D. R. (1991) · PubMed · Cited by 610
Perktold, K., & Rappitsch, G. (1995) · Journal of Biomechanics · doi:10.1016/0021-9290(95)95273-8 · Cited by 493
Bigger, J. T., Fleiss, J. L., Steinman, R. C., Rolnitzky, L. M., Schneider, W. J., & Stein, P. K. (1995) · Circulation · doi:10.1161/01.cir.91.7.1936 · Cited by 443
Three‐dimensional phase contrast angiography
Dumoulin, C. L., Souza, S. P., Walker, M. F., & Wagle, W. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910090117 · Cited by 432
Schöning, M., Walter, J., & Scheel, P. (1994) · Stroke · doi:10.1161/01.str.25.1.17 · Cited by 299
Diameter and compliance in the human common carotid artery — variations with age and sex
Hansen, F., Mangell, P., Sonesson, B., & Länne, T. (1995) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)00090-5 · Cited by 293
Van Hoogenhuyze, D., Weinstein, N., Martin, G. J., Weiss, J. S., Schaad, J. W., Sahyouni, X. N., Fintel, D., Remme, W. J., & Singer, D. H. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90327-h · Cited by 206
Hemodynamics of the normal human carotid bifurcation: In vitro and in vivo studies
Ku, D. N., Giddens, D. P., Phillips, D. J., & Strandness, D. E. (1985) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(85)90003-1 · Cited by 187
Cited by
Vignon-Clementel, I. E., Alberto Figueroa, C., Jansen, K. E., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.04.014 · Cited by 646
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638
A coupled momentum method for modeling blood flow in three-dimensional deformable arteries
Figueroa, C. A., Vignon-Clementel, I. E., Jansen, K. E., Hughes, T. J. R., & Taylor, C. A. (2006) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2005.11.011 · Cited by 547
Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery
Garbey, M., Sun, N., Merla, A., & Pavlidis, I. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891930 · Cited by 402
Pulse Wave Propagation in the Arterial Tree
van de Vosse, F. N., & Stergiopulos, N. (2011) · Annual Review of Fluid Mechanics · doi:10.1146/annurev-fluid-122109-160730 · Cited by 387
Metadata
- Authors
- Holdsworth, D. W., Norley, C. J. D., Frayne, R., Steinman, D. A., & Rutt, B. K.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 20
- Issue
- 3
- Pages
- 219-240
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2055473405
- Cited by
- 338
- References
- 21
- FWCI
- 2.26
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Characterization of common carotid artery blood-flow waveforms in normal human subjects. https://app.cochat.ai/papers/10.1088/0967-3334/20/3/301
- The paper
- Holdsworth, D. W., Norley, C. J. D., Frayne, R., Steinman, D. A., & Rutt, B. K. (1999). Characterization of common carotid artery blood-flow waveforms in normal human subjects. Physiological Measurement. https://doi.org/10.1088/0967-3334/20/3/301
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.