The difference in pulse transit time to the toe and finger measured by photoplethysmography
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
Blood pressure pulse wave velocity (PWV) is a parameter which is related to arterial distensibility. Its direct assessment, by measuring the appearance time of a pressure pulse in two sites along an artery and the distance between the two sites, is complicated and inaccurate. In the current study, pulse transit time (PTT) to the toes and fingers of 44 normotensive male subjects was measured by photoplethysmography (PPG) and ECG. The arrival time of the pulses at the toe and finger was determined from the foot of the systolic rise of the PPG signal, i.e. at end-diastolic time. Two parameters, which are related to PWV, were tested: the time delay between the ECG R-wave and the arrival time of the pulses at the toe (E-T PTT), and the difference in the transit time of the blood pressure pulses between the toe and finger (T-F PTTD). E-T PTT and T-F PTTD decreased as functions of the subject's age and systolic blood pressure (SBP), but their dependence on the diastolic blood pressure (DBP) was not statistically significant. The decrease of the PTT parameters with age is attributed to the direct structural decrease of the arterial compliance with age and not to functional effects associated with the increase of the blood pressure with age, since the PTT parameters did not depend on DBP though the measurements were performed at end-diastole.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Aortic pulse wave velocity as a marker of cardiovascular risk in hypertensive patients
Blacher, J., Asmar, R., Djane, S., London, G. M., & Safar, M. E. (1999) · Hypertension · doi:10.1161/01.hyp.33.5.1111 · Cited by 1,493
Asmar, R., Benetos, A., Topouchian, J., Laurent, P., Pannier, B., Brisac, A.-M., Target, R., & Levy, B. I. (1995) · Hypertension · doi:10.1161/01.hyp.26.3.485 · Cited by 1,376
Avolio, A. P., Deng, F. Q., Li, W. Q., Luo, Y. F., Huang, Z. D., Xing, L. F., & O'Rourke, M. F. (1985) · Circulation · doi:10.1161/01.cir.71.2.202 · Cited by 839
Arterial stiffness, systolic blood pressure, and logical treatment of arterial hypertension.
O'Rourke, M. (1990) · Hypertension · doi:10.1161/01.hyp.15.4.339 · Cited by 622
Benetos, A., Laurent, S., Hoeks, A. P., Boutouyrie, P. H., & Safar, M. E. (1993) · Arteriosclerosis and Thrombosis: A Journal of Vascular Biology · doi:10.1161/01.atv.13.1.90 · Cited by 587
van der Heijden-Spek, J. J., Staessen, J. A., Fagard, R. H., Hoeks, A. P., Boudier, H. A. S., & Van Bortel, L. M. (2000) · Hypertension · doi:10.1161/01.hyp.35.2.637 · Cited by 388
McVeigh, G. E., Bratteli, C. W., Morgan, D. J., Alinder, C. M., Glasser, S. P., Finkelstein, S. M., & Cohn, J. N. (1999) · Hypertension · doi:10.1161/01.hyp.33.6.1392 · Cited by 381
Bank, A. J., Wilson, R. F., Kubo, S. H., Holte, J. E., Dresing, T. J., & Wang, H. (1995) · Circulation Research · doi:10.1161/01.res.77.5.1008 · Cited by 164
Aortic compliance measurements using doppler ultrasound: In vivo biochemical correlates
Lehmann, E. D., Hopkins, K. D., & Gosling, R. G. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90087-5 · Cited by 129
Nagai, Y., Fleg, J. L., Kemper, M. K., Rywik, T. M., Earley, C. J., & Metter, E. J. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00146-x · Cited by 75
Jago, J. R., & Murray, A. (1988) · Clinical Physics and Physiological Measurement · doi:10.1088/0143-0815/9/4/003 · Cited by 74
Increase in pulse transit time to the foot after epidural anaesthesia treatment
Babchenko, A., Davidson, E. M., Adler, D., Ginosar, Y., Kurz, V., & Nitzan, M. (2000) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344874 · Cited by 57
Self-citationVerylow frequency variability in arterial blood pressure and blood volume pulse
Nitzan, M., Babchenko, A., & Khanokh, B. (1999) · Medical & Biological Engineering & Computing · doi:10.1007/bf02513266 · Cited by 56
Self-citationInfluence of thoracic sympathectomy on cardiac induced oscillations in tissue blood volume
Nitzan, M., Babchenko, A., Shemesh, D., & Alberton, J. (2001) · Medical & Biological Engineering & Computing · doi:10.1007/bf02345149 · Cited by 47
Self-citationAortic pulse wave velocity in young normotensives with a family history of hypertension
Rajzer, M. W., Klocek, M., Kawecka−Jaszcz, K., Czarnecka, D., Baran, W., Dudek, K., & Petriczek, T. (1999) · Journal of Hypertension · doi:10.1097/00004872-199917121-00006 · Cited by 47
Assessment of arterial distensibility by automatic pulse wave velocity measurement.
Lehmann, E. D., Hopkins, K. D., & Gosling, R. G. (1996) · PubMed · Cited by 38
Okada, M., Kimura, S., & Okada, M. (1986) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441621 · Cited by 26
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“In the same year Nitzan et al (2002) also published age-related changes in PTT differences between finger and toe sites for adults.”
BackgroundToward ubiquitous blood pressure monitoring via pulse transit time: Theory and practice
Mukkamala, R., Hahn, J.-O., Inan, O. T., Mestha, L. K., Kim, C.-S., Toreyin, H., & Kyal, S. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2441951 · Cited by 935
“7) at rest typically ranges from 180 to 260 ms (finger) [98], [147], [148], [152], [153], 125 to 155 ms (ear) [152], [153], and 180 to 330 ms (toe) [144], [152], [153].”
MethodThe use of photoplethysmography for assessing hypertension
Elgendi, M., Fletcher, R., Liang, Y., Howard, N., Lovell, N. H., Abbott, D., Lim, K., & Ward, R. (2019) · npj Digital Medicine · doi:10.1038/s41746-019-0136-7 · Cited by 625
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Smart Vest: Wearable multi-parameter remote physiological monitoring system
Pandian, P. S., Mohanavelu, K., Safeer, K. P., Kotresh, T. M., Shakunthala, D. T., Gopal, P., & Padaki, V. C. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2007.05.014 · Cited by 423
Metadata
- Authors
- Nitzan, M., Khanokh, B., & Slovik, Y.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2001-12-19
- Volume
- 23
- Issue
- 1
- Pages
- 85-93
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2140401938
- Cited by
- 218
- References
- 17
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.