CoChat

Bioelectrical impedance vector analysis in haemodialysis patients: relation between oedema and mortality

Open access
Nescolarde, L, Piccoli, A, Román, A, Núñez, A, Morales, R, Tamayo, J, Doñate, T, Rosell, J · 2004 · Physiological Measurement
Cited by 81

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

In this work, bioelectrical impedance vector analysis (BIVA) method is used in a sample of haemodialysis patients in stable (without oedema) and critical (hyperhydrated and malnutrition) states, in order to establish the relation between hyperhydration (oedema) and mortality. The measurements obtained were single frequency (50 kHz), tetrapolar (hand-foot) complex impedance measurements (vector components are: resistance R and reactance Xc). The impedance components were standardized by the height H of the subjects, (R/H and Xc/H) to obtain de impedance vector Z/H, that is represented in the RXc plot (abscise R/H, ordinate Xc/H). Measurements were performed on a sample of 74 patients (30 men and 44 women, 18-70 year, body mass index (BMI), 19-30 kg m(-2)) at the Saturnino Lora University Hospital in Santiago de Cuba. The 46 stable patients comprised 28 men and 18 women; the 28 critical patients 16 men and 12 women. The reference population consisted of 1196 healthy adult subjects living in Santiago de Cuba (689 men and 507 women, 18-70 year, BMI 19-30 kg m(-2)). We used the RXc plot with the BIVA method to characterize the reference population using the 50%, 75% and 95% tolerance ellipses. Student's t-test and Hotelling's T2-test were used to analyse the separation of groups obtained by means of clinical diagnosis and those obtained by BIVA. We obtained a significant difference (P < 0.05) in R/H, Xc/H and phase angle (PA) in men as in women between the location of Z/H vectors in the RXc graph and the separation made by the doctors between stable and critical patients. Critical (hyperhydrated) patients were located below the inferior pole of the 75% tolerance ellipse, whereas stable patients were within the tolerance ellipses. Some cases classified as stable by the clinic were classified as hyperhydrated by BIVA with 100% sensitivity and 48% specificity. In conclusion, the BIVA method could be used to classify patients by hydration state and to predict survival. Advantages of the method are its simplicity, objectivity and that it does not require the definition of patient dry weight.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/25/5/016

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
Nescolarde, L., Piccoli, A., Román, A., Núñez, A., Morales, R., Tamayo, J., Doñate, T., & Rosell, J.
Venue
Physiological Measurement
Published
2004-08-11
Volume
25
Issue
5
Pages
1271-1280
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2025247542
Cited by
81
References
5
FWCI
1.52
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.