Cited by 248ECG Monitoring and AnalysisNon-Invasive Vital Sign MonitoringAdvanced Sensor and Energy Harvesting Materials

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Novel dry electrodes for ECG monitoring

Open access
Gruetzmann, Anna, Hansen, Stefan, Müller, Jörg·2007·Physiological Measurement

Abstract

The development, fabrication and characterization of two novel dry bioelectrodes--conductive and capacitive ones--for biopotential monitoring are presented. The new electrodes have the potential to improve the applicability of dry electrodes in ambulant recording of ECG by reducing motion artifacts as well as the contact impedance to the skin. Furthermore, a passive filter network is integrated into the new electrodes to suppress slow offset fluctuation of the ECG signal caused e.g. by motions like breathing or changes in the electrode-skin interface properties. Compared to standard gel electrodes these new electrodes exhibit equivalent and superior contact impedances and biosignals. The integrated filter network effectively suppresses fluctuating offset potentials.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/28/11/005

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 12 references

Cited by

Sorted by citations

Items 101–200 of 248

Metadata

Authors
Gruetzmann, A., Hansen, S., & Müller, J.
Affiliations
Hamburg University of Technology (DE)
Venue
Physiological Measurement
Published
2007-10-12
Volume
28
Issue
11
Pages
1375-1390
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2138886665
Cited by
248
References
12
Citations by year
2026: 2 · 2025: 5 · 2024: 15 · 2023: 21 · 2022: 11 · 2021: 15 · 2020: 19 · 2019: 25 · 2018: 21 · 2017: 9 · 2016: 22 · 2015: 18 · 2014: 15 · 2013: 17 · 2012: 10
FWCI
3.28
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
Keywords
dry electrodes, ECG monitoring, conductive electrodes, capacitive electrodes, motion artifacts, contact impedance, skin-electrode interface, biopotential monitoring
MeSH terms
Elasticity, Electrodes, Equipment Design, Evoked Potentials, Humans, Electrocardiography, Ambulatory, Artifacts, Electric Impedance, Equipment Failure Analysis, Electric Capacitance, Cardiac Electrophysiology

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review