CoChat

Evaluation of a wearable orthosis and an associated algorithm for tremor suppression

Open access
Manto, Mario, Rocon, Eduardo, Pons, Jose, Belda, Juan Manuel, Camut, Stephane · 2007 · Physiological Measurement
Cited by 41

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

We describe a wearable orthosis and an associated algorithm for the simultaneous assessment and treatment of essential tremor, one of the most common movement disorders in humans involving an overactivity of the olivo-cerebellar pathways. A motor providing effective viscosity is fixed on a wearable orthosis in the upper limbs. The motor is controlled by a personal computer with software processing in real time the position and rate of rotation of the joint detected by a chip gyroscope. The orthosis can be used in a monitoring mode and in an active mode. The range of tremor suppression of the signals above the orthosis operational limit ranges from about 3% (percentile 5) to about 79% (percentile 95) in relation to energy in the monitoring mode. Considering both postural and kinetic, the mean tremor energy decreased from 55.49 +/- 22.93 rad2 s(-3) in the monitoring mode to 15.66 +/- 7.29 rad2 s(-3) in the active mode. Medians of power reduction were below 60% for the wrist and the elbow. In addition to supplying new information on the interactions between kinematics, dynamics and tremor genesis, this non-invasive technique is an alternative to current therapies. This new approach will provide new insights into the understanding of motor control.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/28/4/007

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

See all 41

Metadata

Authors
Manto, M., Rocon, E., Pons, J., Belda, J. M., & Camut, S.
Venue
Physiological Measurement
Published
2007-03-20
Volume
28
Issue
4
Pages
415-425
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W1995760487
Cited by
41
References
10
FWCI
0.62
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Evaluation of a wearable orthosis and an associated algorithm for tremor suppression. https://app.cochat.ai/papers/10.1088/0967-3334/28/4/007
The paper
Manto, M., Rocon, E., Pons, J., Belda, J. M., & Camut, S. (2007). Evaluation of a wearable orthosis and an associated algorithm for tremor suppression. Physiological Measurement. https://doi.org/10.1088/0967-3334/28/4/007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.