Evaluation of a wearable orthosis and an associated algorithm for tremor suppression
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
We describe a wearable orthosis and an associated algorithm for the simultaneous assessment and treatment of essential tremor, one of the most common movement disorders in humans involving an overactivity of the olivo-cerebellar pathways. A motor providing effective viscosity is fixed on a wearable orthosis in the upper limbs. The motor is controlled by a personal computer with software processing in real time the position and rate of rotation of the joint detected by a chip gyroscope. The orthosis can be used in a monitoring mode and in an active mode. The range of tremor suppression of the signals above the orthosis operational limit ranges from about 3% (percentile 5) to about 79% (percentile 95) in relation to energy in the monitoring mode. Considering both postural and kinetic, the mean tremor energy decreased from 55.49 +/- 22.93 rad2 s(-3) in the monitoring mode to 15.66 +/- 7.29 rad2 s(-3) in the active mode. Medians of power reduction were below 60% for the wrist and the elbow. In addition to supplying new information on the interactions between kinematics, dynamics and tremor genesis, this non-invasive technique is an alternative to current therapies. This new approach will provide new insights into the understanding of motor control.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perlmutter, J. S., & Mink, J. W. (2006) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.29.051605.112824 · Cited by 1,073 · cited 2×
“Although deep brain stimulation has provided remarkable benefits for people with a variety of neurologic conditions (Perlmutter and Mink 2006), alternative solutions are of interest for refractory cases.”
Neural correlates of reach errors
Diedrichsen, J., Hashambhoy, Y., Rane, T., & Shadmehr, R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.1874-05.2005 · Cited by 622 · cited 2×
“Therefore, although both central neurostimulation and lesions are effective to manage tremor in many cases, both techniques significantly impair the capacity of the brain to form internal models of action, the adaptative control of reaching depending on the integrity of the cerebellothalamocortical pathway (Chen et al…”
BackgroundDeuschl, G., Raethjen, J., Lindemann, M., & Krack, P. (2001) · Muscle & Nerve · doi:10.1002/mus.1063 · Cited by 508 · cited 2×
“…oscillations, (b) oscillations due to reflexes, (c) oscillations generated 0967-3334/07/040415+11$30.00 © 2007 IOP Publishing Ltd Printed in the UK 415 by neuronal generators in the central nervous system, (d) oscillations resulting from impaired feedforward and feedback loops (Deuschl et al 2001).”
BackgroundInfluentialCohen, O., Pullman, S., Jurewicz, E., Watner, D., & Louis, E. D. (2003) · Archives of Neurology · doi:10.1001/archneur.60.3.405 · Cited by 298
Suicide after successful deep brain stimulation for movement disorders
Burkhard, P. R., Vingerhoets, F. J. G., Berney, A., Bogousslavsky, J., Villemure, J.-G., & Ghika, J. (2004) · Neurology · doi:10.1212/01.wnl.0000145603.48221.b5 · Cited by 219 · cited 1×
“%) has been recently found in patients treated with deep brain stimulation (Burkhard et al 2004).”
BackgroundHua, S. E., & Lenz, F. A. (2005) · Journal of Neurophysiology · doi:10.1152/jn.00527.2004 · Cited by 134 · cited 2×
“However, recordings of neurons in human have provided conflicting results with the hypothesis of continuous olivo-cerebellar driving of the motor cortex via thalamic connections ( Hua and Lenz 2005 ).”
ResultEssential tremor—the most common movement disorder in older people
Thanvi, B., Lo, N., & Robinson, T. (2006) · Age and Ageing · doi:10.1093/ageing/afj072 · Cited by 102
Rehabilitation Robotics: a Wearable Exo-Skeleton for Tremor Assessment and Suppression
Rocon, E., Ruiz, A. F., Pons, J. L., Belda-Lois, J. M., & Sanchez-Lacuesta, J. J. (2006) · Proceedings of the 2005 IEEE International Conference on Robotics and Automation · doi:10.1109/robot.2005.1570451 · Cited by 87 · cited 3×
“The interaction force between the exoskeleton and the user is measured by a force sensor based on strain gauges (Rocon et al 2005).”
BackgroundMethodInfluentialSelf-citationDynamically responsive intervention for tremor suppression
Manto, M., Topping, M., Soede, M., Sanchez-Lacuesta, J., Harwin, W., Pons, J., Williams, J., Skaarup, S., & Normie, L. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213635 · Cited by 81 · cited 1×
“Further research in the field of actuators will clarify our understanding of the short-term, middle-term and longterm adaptation of human motor behaviour to wearable active orthosis (Manto et al 2003).”
BackgroundSelf-citationRandomized trial comparing primidone initiation schedules for treating essential tremor
O'Suilleabhain, P., & Dewey, R. B. (2002) · Movement Disorders · doi:10.1002/mds.10083 · Cited by 53
Cited by
Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method
Taheri, B., Case, D., & Richer, E. (2015) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2014.2317948 · Cited by 53
“to the characteristics of the patient’s tremor [10], [19].”
BackgroundActive tremor estimation and suppression in human elbow joint
Taheri, B., Case, D., & Richer, E. (2011) · ASME 2011 Dynamic Systems and Control Conference and Bath/ASME Symposium on Fluid Power and Motion Control, Volume 2 · doi:10.1115/dscc2011-6185 · Cited by 18
“An exoskeleton can then be employed to generate a motion equal but opposite to the tremor [11, 13, 17].”
MethodGrimaldi, G., Lammertse, P., Van Den Braber, N., Meuleman, J., & Manto, M. (2008) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2008.926726 · Cited by 11
Self-citation
Metadata
- Authors
- Manto, M., Rocon, E., Pons, J., Belda, J. M., & Camut, S.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2007-03-20
- Volume
- 28
- Issue
- 4
- Pages
- 415-425
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1995760487
- Cited by
- 41
- References
- 10
- FWCI
- 0.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Evaluation of a wearable orthosis and an associated algorithm for tremor suppression. https://app.cochat.ai/papers/10.1088/0967-3334/28/4/007
- The paper
- Manto, M., Rocon, E., Pons, J., Belda, J. M., & Camut, S. (2007). Evaluation of a wearable orthosis and an associated algorithm for tremor suppression. Physiological Measurement. https://doi.org/10.1088/0967-3334/28/4/007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.