Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method

Taheri, Behzad, Case, David, Richer, Edmond · 2015 · IEEE/ASME Transactions on Mechatronics

The DOI matches its Crossref record; 44 of the 46 references it cites were found in a registry or an index.

Abstract

Tremor is a rhythmical and involuntary oscillatory movement of a body part. In addition to social embarrassment, tremor can be debilitating for daily activities. Recently, wearable active exoskeletons emerged as a noninvasive tremor suppression alternative to medication or surgery. The challenge in musculoskeletal tremor suppression is identifying and attenuating the tremor motion without adding resistance to the patient's intentional motion. In this research, an adaptive tremor suppression algorithm was designed to estimate the tremor fundamental frequency and calculate the proper suppressive force to be applied by the orthosis to the patient's arm. Stability of the closed-loop system and robustness against the parametric uncertainties were analyzed. An experimental setup was designed and developed to emulate the dynamics of a human wrist with intentional and tremor motion. A pneumatic cylinder and a sliding mode integral controller was used to apply orthotic suppressive force. The algorithm was implemented with an NI cRIO real-time controller and tested using clinical data from ten patients with severe pathological tremor. Experimental results showed tracking of the tremor frequency with less than 3-s response time, and an average 34.5 dB (98.1%) and 11.8 dB (74.3%) reduction of tremor amplitude at the fundamental and second-harmonic frequencies, respectively. The average resistance force to the intentional motion was 0.7 N and the average position error was 2.08% (0.18 dB). The results were compared with passive tremor suppression using a tunable magnetorheological damper.

Overview

Integrity signals

Registry

Crossref · 10.1109/tmech.2014.2317948

Cites

44 of 44 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

1 more claim about this paper

Create a free account to see every claim other papers make about this one.

See all claims — free account

Citations

Cites

Show all 44 references

Research works printed but not linked: 1

  1. khalil, 2002, Nonlinear Systems, 3

Cited by

See all 56

Metadata

Authors
Taheri, B., Case, D., & Richer, E.
Affiliations
Southern Methodist University (US)
Venue
IEEE/ASME Transactions on Mechatronics
Published
2015-04
Volume
20
Issue
2
Pages
717-727
ISSN
  • 1083-4435 (ISSN-L)
  • 1941-014X
OpenAlex
W2167260503
Cited by
53
References
46
Citations by year
2026: 1 · 2025: 2 · 2024: 6 · 2023: 4 · 2022: 5 · 2021: 7 · 2020: 4 · 2019: 10 · 2018: 4 · 2017: 4 · 2016: 5 · 2015: 1
FWCI
1.73
Type
journal article
Language
en
Open access
closed
Locations
IEEE/ASME Transactions on Mechatronics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
  • Life Sciences › Neuroscience › Cognitive Neuroscience › Motor Control and Adaptation
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
pathological tremor, tremor suppression, torque estimation, fundamental frequency estimation, adaptive control, pneumatic actuators, closed-loop stability, parameter uncertainty, magnetorheological damper, orthosis

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method. https://app.cochat.ai/papers/10.1109/tmech.2014.2317948
The paper
Taheri, B., Case, D., & Richer, E. (2015). Adaptive Suppression of Severe Pathological Tremor by Torque Estimation Method. IEEE/ASME Transactions on Mechatronics. https://doi.org/10.1109/tmech.2014.2317948

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.