CoChat

Comparative reproducibility of dermal microvascular blood flow changes in response to acetylcholine iontophoresis, hyperthermia and reactive hyperaemia

Open access
Agarwal, Sharad C, Allen, John, Murray, Alan, Purcell, Ian F · 2010 · Physiological Measurement
Cited by 81

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

Laser Doppler fluxmetry (LDF) can non-invasively measure skin microvascular changes in response to acetylcholine (ACh), local heating of the skin and reactive hyperaemia following arterial occlusion. Various studies have used microvascular changes in response to these stimuli, especially ACh iontophoresis and local heating, as a surrogate marker of endothelial function. There are few data in the literature regarding the comparative reproducibility of microvascular perfusion changes induced by the three stimuli. The aim of this study was to systematically assess and compare the reproducibility of skin microcirculatory function in response to each of these challenges. Ten healthy non-smoking subjects (seven males) median age 36 years (range 23-46), with no history of hypertension, diabetes, coronary artery disease or any connective tissue disorder, were studied. Changes in skin microcirculation in response to ACh iontophoresis, local heating of the skin and post-occlusive reactive hyperaemia, on two separate days (median 31, range 11-42 days), were assessed in all subjects. We measured three parameters: the change in perfusion from baseline perfusion (peak minus baseline perfusion), the relative percentage change in perfusion from baseline (peak--baseline)/baseline x 100 (%) and also the time-to-peak perfusion. The reproducibility of the change in perfusion had coefficients of variation (CV) of 9.3% for local skin heating, 19.4% for reactive hyperaemia and 25.5% for ACh iontophoresis. The relative percentage change in perfusion from baseline was more variable with CVs ranging from 23% to 39%. The coefficient of variation of time-to-peak perfusion was 7.0% for heating, 15.1% for reactive hyperaemia and 10.4% for ACh iontophoresis. We have shown that microcirculatory changes measured by the change in perfusion from baseline and time-to-peak perfusion in response to ACh, post-occlusive reactive hyperaemia and local skin heating had good reproducibility when carried out in a controlled environment with a standardized protocol. Relative change in perfusion had relatively poor reproducibility. The change in perfusion and time-to-peak perfusion for local skin heating were the most reproducible overall.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/31/1/001

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

See all 81

Metadata

Authors
Agarwal, S. C., Allen, J., Murray, A., & Purcell, I. F.
Venue
Physiological Measurement
Published
2009-11-26
Volume
31
Issue
1
Pages
1-11
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W1977083740
Cited by
81
References
3
FWCI
2.95
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Comparative reproducibility of dermal microvascular blood flow changes in response to acetylcholine iontophoresis, hyperthermia and reactive hyperaemia. https://app.cochat.ai/papers/10.1088/0967-3334/31/1/001
The paper
Agarwal, S. C., Allen, J., Murray, A., & Purcell, I. F. (2010). Comparative reproducibility of dermal microvascular blood flow changes in response to acetylcholine iontophoresis, hyperthermia and reactive hyperaemia. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/1/001

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.