How to detect and reduce movement artifacts in near-infrared imaging using moving standard deviation and spline interpolation
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Near-infrared imaging (NIRI) is a neuroimaging technique which enables us to non-invasively measure hemodynamic changes in the human brain. Since the technique is very sensitive, the movement of a subject can cause movement artifacts (MAs), which affect the signal quality and results to a high degree. No general method is yet available to reduce these MAs effectively. The aim was to develop a new MA reduction method. A method based on moving standard deviation and spline interpolation was developed. It enables the semi-automatic detection and reduction of MAs in the data. It was validated using simulated and real NIRI signals. The results show that a significant reduction of MAs and an increase in signal quality are achieved. The effectiveness and usability of the method is demonstrated by the improved detection of evoked hemodynamic responses. The present method can not only be used in the postprocessing of NIRI signals but also for other kinds of data containing artifacts, for example ECG or EEG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
A New Method of Interpolation and Smooth Curve Fitting Based on Local Procedures
Akima, H. (1970) · Journal of the ACM · doi:10.1145/321607.321609 · Cited by 2,063
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Cui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Self-citationPinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Brigadoi, S., Ceccherini, L., Cutini, S., Scarpa, F., Scatturin, P., Selb, J., Gagnon, L., Boas, D. A., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.082 · Cited by 557
Temporal Derivative Distribution Repair (TDDR): A motion correction method for fNIRS
Fishburn, F. A., Ludlum, R. S., Vaidya, C. J., & Medvedev, A. V. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.025 · Cited by 516
Herold, F., Wiegel, P., Scholkmann, F., & Müller, N. (2018) · Journal of Clinical Medicine · doi:10.3390/jcm7120466 · Cited by 482
Self-citationStatistical analysis of fNIRS data: A comprehensive review
Tak, S., & Ye, J. C. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.016 · Cited by 465
Cooper, R. J., Selb, J., Gagnon, L., Phillip, D., Schytz, H. W., Iversen, H. K., Ashina, M., & Boas, D. A. (2012) · Frontiers in Neuroscience · doi:10.3389/fnins.2012.00147 · Cited by 421
“In cases where real motion artifact contaminated NIRS data has been used, the utility of a correction technique has been quantified using some measure of improvement in signal-to-noise ratio of the corrected NIRS timecourse (Izzetoglu et al., 2010; Scholkmann et al., 2010; Molavi and Dumont, 2012).”
BackgroundMethodInfluentialReindl, V., Gerloff, C., Scharke, W., & Konrad, K. (2018) · NeuroImage · doi:10.1016/j.neuroimage.2018.05.060 · Cited by 411
Chen, W.-L., Wagner, J., Heugel, N., Sugar, J., Lee, Y.-W., Conant, L., Malloy, M., Heffernan, J., Quirk, B., Zinos, A., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00724 · Cited by 382
Autoregressive model based algorithm for correcting motion and serially correlated errors in fNIRS
Barker, J. W., Aarabi, A., & Huppert, T. J. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.001366 · Cited by 337
A Review on the Use of Wearable Functional Near‐Infrared Spectroscopy in Naturalistic Environments
Pinti, P., Aichelburg, C., Gilbert, S., Hamilton, A., Hirsch, J., Burgess, P., & Tachtsidis, I. (2018) · Japanese Psychological Research · doi:10.1111/jpr.12206 · Cited by 325
Herold, F., Wiegel, P., Scholkmann, F., Thiers, A., Hamacher, D., & Schega, L. (2017) · Neurophotonics · doi:10.1117/1.nph.4.4.041403 · Cited by 314
Self-citationQuaresima, V., Bisconti, S., & Ferrari, M. (2012) · Brain and Language · doi:10.1016/j.bandl.2011.03.009 · Cited by 276
Concurrent fNIRS and EEG for Brain Function Investigation: A Systematic, Methodology-Focused Review
Li, R., Yang, D., Fang, F., Hong, K.-S., Reiss, A. L., & Zhang, Y. (2022) · Sensors · doi:10.3390/s22155865 · Cited by 236
“Multiple algorithms have been developed to identify and correct motion artifacts in raw fNIRS signals, such as spline interpolation [38], wave-”
MethodThe effects of interaction quality on neural synchrony during mother-child problem solving
Nguyen, T., Schleihauf, H., Kayhan, E., Matthes, D., Vrtička, P., & Hoehl, S. (2020) · Cortex · doi:10.1016/j.cortex.2019.11.020 · Cited by 225
Functional Near Infrared Spectroscopy: Enabling routine functional brain imaging
Yücel, M. A., Selb, J. J., Huppert, T. J., Franceschini, M. A., & Boas, D. A. (2017) · Current Opinion in Biomedical Engineering · doi:10.1016/j.cobme.2017.09.011 · Cited by 222
Jahani, S., Setarehdan, S. K., Boas, D. A., & Yücel, M. A. (2018) · Neurophotonics · doi:10.1117/1.nph.5.1.015003 · Cited by 208
“The method relies on the correct identification of motion artifact segments.(19) Wavelet filtering is based on decomposing the data into wavelet coefficients.”
MethodBetween-brain connectivity during imitation measured by fNIRS
Holper, L., Scholkmann, F., & Wolf, M. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.06.028 · Cited by 207
“Since head and body movement can cause movement artifacts (MAs) in the [O2Hb] and [HHb] signals, the method presented in Scholkmann et al. (2010) was used to reduce MAs from these signals prior to analysis.”
MethodSelf-citationInfant and Adult Brains Are Coupled to the Dynamics of Natural Communication
Piazza, E. A., Hasenfratz, L., Hasson, U., & Lew-Williams, C. (2020) · Psychological Science · doi:10.1177/0956797619878698 · Cited by 202
Age-related changes in prefrontal activity during walking in dual-task situations: A fNIRS study
Beurskens, R., Helmich, I., Rein, R., & Bock, O. (2014) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2014.03.005 · Cited by 191
Di Lorenzo, R., Pirazzoli, L., Blasi, A., Bulgarelli, C., Hakuno, Y., Minagawa, Y., & Brigadoi, S. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2019.06.056 · Cited by 181
“3 Wavelet 338 The wavelet filtering available in Homer2, first pr o osed by Molavi and Dumont 339 (2012), is a function that detects and corrects art ifacts channel-by-channel in a single step.”
fNIRS response during walking — Artefact or cortical activity? A systematic review
Vitorio, R., Stuart, S., Rochester, L., Alcock, L., & Pantall, A. (2017) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2017.10.002 · Cited by 177
“, 2016) within the movement artefact reduction algorithm (MARA) (Scholkmann et al., 2010) or using wavelet filtering and correlation-based signal improvement (Maidan et al.”
InfluentialPfeifer, M. D., Scholkmann, F., & Labruyère, R. (2018) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2017.00641 · Cited by 173
“Furthermore, the motion artifact detection method applied in the self-implemented signal processing (Scholkmann et al., 2010) is more sensitive and allows for a more fine-grained detection of motion artifacts compared to the manual method applied within nirsLAB.”
BackgroundMethodSelf-citationOptical imaging and spectroscopy for the study of the human brain: status report
Ayaz, H., Baker, W. B., Blaney, G., Boas, D. A., Bortfeld, H., Brady, K., Brake, J., Brigadoi, S., Buckley, E. M., Carp, S. A., et al. (2022) · Neurophotonics · doi:10.1117/1.nph.9.s2.s24001 · Cited by 170
Self-citationYücel, M. A., Selb, J., Boas, D. A., Cash, S. S., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.06.054 · Cited by 86
“, 2007)) and methods that do not require extra measurements (such as principal component analysis, Kalman filtering, wavelet based filtering and spline interpolation (Izzetoglu et al., 2010; Molavi and Dumont, 2012; Scholkmann et al., 2010; Zhang et al., 2005)).”
Sensor space group analysis for fNIRS data
Tak, S., Uga, M., Flandin, G., Dan, I., & Penny, W. D. (2016) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2016.03.003 · Cited by 83
Classification of three anesthesia stages based on near-infrared spectroscopy signals
Liu, Z., Si, L., Shi, S., Li, J., Zhu, J., Lee, W. H., Lo, S.-L., Yan, X., Chen, B., Fu, F., et al. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3409163 · Cited by 71
“Then for complex movement artifacts, the movement artifact reduction algorithm (MARA) was used to remove them [34].”
MethodMovement artefact removal from NIRS signal using multi-channel IMU data
Siddiquee, M. R., Marquez, J. S., Atri, R., Ramon, R., Perry Mayrand, R., & Bai, O. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0554-9 · Cited by 33
The role of expectation in multisensory body representation – neural evidence
Ferri, F., Ambrosini, E., Pinti, P., Merla, A., & Costantini, M. (2017) · European Journal of Neuroscience · doi:10.1111/ejn.13629 · Cited by 17
Metadata
- Authors
- Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-03-22
- Volume
- 31
- Issue
- 5
- Pages
- 649-662
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1996776986
- Cited by
- 683
- References
- 35
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.