How to detect and reduce movement artifacts in near-infrared imaging using moving standard deviation and spline interpolation
Open accessThe DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
Near-infrared imaging (NIRI) is a neuroimaging technique which enables us to non-invasively measure hemodynamic changes in the human brain. Since the technique is very sensitive, the movement of a subject can cause movement artifacts (MAs), which affect the signal quality and results to a high degree. No general method is yet available to reduce these MAs effectively. The aim was to develop a new MA reduction method. A method based on moving standard deviation and spline interpolation was developed. It enables the semi-automatic detection and reduction of MAs in the data. It was validated using simulated and real NIRI signals. The results show that a significant reduction of MAs and an increase in signal quality are achieved. The effectiveness and usability of the method is demonstrated by the improved detection of evoked hemodynamic responses. The present method can not only be used in the postprocessing of NIRI signals but also for other kinds of data containing artifacts, for example ECG or EEG signals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, N. E., Shen, Z., Long, S. R., Wu, M. C., Shih, H. H., Zheng, Q., Yen, N.-C., Tung, C. C., & Liu, H. H. (1998) · Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1998.0193 · Cited by 23,564
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
A New Method of Interpolation and Smooth Curve Fitting Based on Local Procedures
Akima, H. (1970) · Journal of the ACM · doi:10.1145/321607.321609 · Cited by 2,063
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Cui, X., Bray, S., & Reiss, A. L. (2010) · NeuroImage · doi:10.1016/j.neuroimage.2009.11.050 · Cited by 807
Spontaneous Low Frequency Oscillations of Cerebral Hemodynamics and Metabolism in Human Adults
Obrig, H., Neufang, M., Wenzel, R., Kohl, M., Steinbrink, J., Einhäupl, K., & Villringer, A. (2000) · NeuroImage · doi:10.1006/nimg.2000.0657 · Cited by 614
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Functional near-infrared spectroscopy: current status and future prospects
Hoshi, Y. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804911 · Cited by 468
Zhang, Y., Brooks, D. H., Franceschini, M. A., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852552 · Cited by 373
Comment on the modified Beer–Lambert law for scattering media
Sassaroli, A., & Fantini, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/n07 · Cited by 352
Hamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329 · cited 1×
“…© 2010 Institute of Physics and Engineering in Medicine Printed in the UK 649 applications in medicine and neuroscience expanded (Boushel et al 2001, Ferrari et al 2004, Wolf et al 2007, Hoshi 2007, Hamaoka et al 2007, Muehlemann et al 2008, Gibson and Dehghani 2009).”
BackgroundWavelet minimum description length detrending for near-infrared spectroscopy
Jang, K. E., Tak, S., Jung, J., Jang, J., Jeong, Y., & Ye, J. C. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3127204 · Cited by 279
Wolf, M., Wolf, U., Toronov, V., Michalos, A., Paunescu, L. A., Choi, J. H., & Gratton, E. (2002) · NeuroImage · doi:10.1006/nimg.2002.1128 · Cited by 197
Self-citationZhang, Q., Strangman, G. E., & Ganis, G. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.12.048 · Cited by 176
Motion Artifact Cancellation in NIR Spectroscopy Using Wiener Filtering
Izzetoglu, M., Devaraj, A., Bunce, S., & Onaral, B. (2005) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2005.845243 · Cited by 173
Zhang, Q., Brown, E. N., & Strangman, G. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2754714 · Cited by 163
Wireless miniaturized in-vivo near infrared imaging
Muehlemann, T., Haensse, D., & Wolf, M. (2008) · Optics Express · doi:10.1364/oe.16.010323 · Cited by 162
Self-citationGibson, A., & Dehghani, H. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0080 · Cited by 159
Using near-infrared spectroscopy to assess neural activation during object processing in infants
Wilcox, T., Bortfeld, H., Woods, R., Wruck, E., & Boas, D. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852551 · Cited by 152
Brain Auditory Activation Measured by Near-Infrared Spectroscopy (NIRS) in Neonates
Zaramella, P., Freato, F., Amigoni, A., Salvadori, S., Marangoni, P., Suppjei, A., Schiavo, B., & Chiandetti, L. (2001) · Pediatric Research · doi:10.1203/00006450-200102000-00014 · Cited by 143
Zhang, Q., Brown, E. N., & Strangman, G. E. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804706 · Cited by 132
Oscillations in cerebral haemodynamics. Implications for functional activation studies.
Elwell, C. E., Springett, R., Hillman, E. M. C., & Delpy, D. T. (1999) · PubMed · Cited by 116
Oscillations in Cerebral Haemodynamics
Elwell, C. E., Springett, R., Hillman, E. M. C., & Delpy, D. T. (1999) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-4717-4_8 · Cited by 112
Karen, T., Morren, G., Haensse, D., Bauschatz, A. S., Bucher, H. U., & Wolf, M. (2008) · Human Brain Mapping · doi:10.1002/hbm.20411 · Cited by 67
Self-citationHaensse, D., Szabó, P., Brown, D., Fauchère, J., Niederer, P. F., Bucher, H.-U., & Wolfa, M. (2005) · Optics Express · doi:10.1364/opex.13.004525 · Cited by 54
Fladby, T., Bryhn, G., Halvorsen, O., Rosé, I., Wahlund, M., Wiig, P., & Wetterberg, L. (2004) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000119966.74298.5c · Cited by 40
A Comparison of Artifact Reduction Methods for Real-Time Analysis of fNIRS Data
Nozawa, T., & Kondo, T. (2009) · Lecture notes in computer science · doi:10.1007/978-3-642-02559-4_45 · Cited by 33
Empirical mode decomposition applied to tissue artifact removal from respiratory signal
Liu, S., He, Q., Gao, R. X., & Freedson, P. S. (2008) · doi:10.1109/iembs.2008.4649991 · Cited by 28
Müller, T., Timmer, J., Reinhard, M., Oehm, E., & Hetzel, A. (2003) · Medical & Biological Engineering & Computing · doi:10.1007/bf02343541 · Cited by 20
Nonlinear singular spectrum analysis
Hsieh, W. W., & Wu, A. (2003) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2002.1007595 · Cited by 15
Ferrari, M., Blasi, R. A. D., Safoue, F., Wei, Q., & Zaccanti, G. (1993) · Advances in experimental medicine and biology · doi:10.1007/978-1-4899-2468-1_3 · Cited by 13
Near-Infrared Imaging in vivo (II): 2-Dimensional Visualization of Tissue Oxygenation State
Araki, R., & Nashimoto, I. (1992) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-3404-4_20 · Cited by 4
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Self-citationPinti, P., Tachtsidis, I., Hamilton, A., Hirsch, J., Aichelburg, C., Gilbert, S., & Burgess, P. W. (2020) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.13948 · Cited by 1,336
Wavelet-based motion artifact removal for functional near-infrared spectroscopy
Molavi, B., & Dumont, G. A. (2012) · Physiological Measurement · doi:10.1088/0967-3334/33/2/259 · Cited by 623
Brigadoi, S., Ceccherini, L., Cutini, S., Scarpa, F., Scatturin, P., Selb, J., Gagnon, L., Boas, D. A., & Cooper, R. J. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.082 · Cited by 557
Temporal Derivative Distribution Repair (TDDR): A motion correction method for fNIRS
Fishburn, F. A., Ludlum, R. S., Vaidya, C. J., & Medvedev, A. V. (2019) · NeuroImage · doi:10.1016/j.neuroimage.2018.09.025 · Cited by 516
Metadata
- Authors
- Scholkmann, F., Spichtig, S., Muehlemann, T., & Wolf, M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-03-22
- Volume
- 31
- Issue
- 5
- Pages
- 649-662
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1996776986
- Cited by
- 683
- References
- 35
- FWCI
- 9.40
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.