Hyolaryngeal excursion as the physiological source of swallowing accelerometry signals
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Swallowing dysfunction, or dysphagia, is a serious condition that can result from any structural or neurological impairment (such as stroke, neurodegenerative disease or brain injury) that affects the swallowing mechanism. The gold-standard method of instrumental swallowing assessment is an x-ray examination known as the videofluoroscopic swallowing study, which involves radiation exposure. Consequently, there is interest in exploring the potential of less invasive methods, with lesser risks of biohazard, to accurately detect swallowing abnormalities. Accelerometry is one such technique, which measures the epidermal vibration signals on a patient's neck during swallowing. Determining the utility of accelerometry signals for detecting dysphagia requires an understanding of the physiological source of the vibrations that are measured on the neck during swallowing. The purpose of the current study was to determine the extent to which movement of the hyoid bone and larynx contributes to the vibration signal that is registered during swallowing accelerometry. This question was explored by mapping the movement trajectories of the hyoid bone and the arytenoid cartilages from lateral videofluoroscopy recordings collected during thin liquid swallowing, and comparing these trajectories to time-linked signals obtained from a dual-axis accelerometer placed on the neck, just anterior to the cricoid cartilage. Participants for this study included 43 adult patients referred for videofluoroscopic swallowing studies to characterize the nature and severity of suspected neurogenic dysphagia. A software program was created to allow frame-by-frame tracking of structural movement on the videofluoroscopy recordings. These movement data were then compared to the integrated acceleration data using multiple linear regressions. The results concur with previous studies, implicating hyolaryngeal excursion as the primary physiological source of swallowing accelerometry signals, with both the hyoid and the larynx contributing approximately equal amounts to the explained variance of the dependent variable, the integrated accelerometry signal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
MBS Measurement Tool for Swallow Impairment—MBSImp: Establishing a Standard
Martin-Harris, B., Brodsky, M. B., Michel, Y., Castell, D. O., Schleicher, M., Sandidge, J., Maxwell, R., & Blair, J. (2008) · Dysphagia · doi:10.1007/s00455-008-9185-9 · Cited by 685 · cited 1×
“In clinical practice, the gold-standard procedure for evaluating swallowing physiology is an x-ray examination known as the videofluoroscopic swallowing study (VFSS) (Logemann 1998, Martin-Harris et al 2008).”
Methodology for detecting swallowing sounds
Takahashi, K., Groher, M., & Michi, K.-I. (1994) · Dysphagia · doi:10.1007/bf00262760 · Cited by 215 · cited 1×
“Cervical auscultation (CA) is one such non-invasive technique, in which a clinician listens to the sounds of swallowing, registered using a stethoscope, microphone or accelerometer (Cichero and Murdoch 2002a, 2002b, Youmans and Stierwalt 2005, Borr et al 2007, Takahashi et al 1994).”
Detection of Swallowing Sounds: Methodology Revisited
Cichero, J. A. Y., & Murdoch, B. E. (2002) · Dysphagia · doi:10.1007/s00455-001-0100-x · Cited by 97
Origin of the Sound Components During Pharyngeal Swallowing in Normal Subjects
Morinière, S., Boiron, M., Alison, D., Makris, P., & Beutter, P. (2008) · Dysphagia · doi:10.1007/s00455-007-9134-z · Cited by 88 · cited 1×
“Morinière et al (2008) used synchronized acoustic and radiographic data and demonstrated three component sounds with close temporal correspondence, respectively, to hyo-laryngeal elevation, UES opening and laryngeal descent or release (which was closely timed with bolus passage through the UES).”
Swallow segmentation with artificial neural networks and multi-sensor fusion
Lee, J., Steele, C. M., & Chau, T. (2009) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2009.07.001 · Cited by 40
Self-citation
Research works printed but not linked: 24
- 10.1007/s00455-007-9078-3 · DOI
- 10.1115/1.2746384 · DOI
- 10.1007/s00455-002-0070-7 · DOI
- 10.1007/PL00009548 · DOI
- Cichero J A, 2002, Ann. Otol. Rhinol. Laryngol., 111, 623, 10.1177/000348940211100710 · DOI · Paper page
- Cichero J A, 2003, J. Med. Speech Lang. Pathol., 11, 34
- Cook I J, 1989, Am. J. Physiol., 257, G748
- Dodds W J, 1988, Am. J. Roentgenol., 150, 1307, 10.2214/ajr.150.6.1307 · DOI · Paper page
- 10.1016/S0003-9969(01)00092-9 · DOI
- 10.1007/s00455-007-9135-y · DOI · Paper page
- 10.1007/s00455-008-9200-1 · DOI
- Lee J, 2008, Physiol. Meas., 29, 1105, 10.1088/0967-3334/29/9/008 · DOI · Paper page
- Leonard R J, 2000, Dysphagia, 15, 146, 10.1007/s004550010017 · DOI · Paper page
- 10.1007/s00455-007-9084-5 · DOI
- Logemann J A, 1998, Manual for the Videofluorographic Study of Swallowing
- 10.1016/j.jelekin.2006.09.011 · DOI
- 10.1044/1092-4388(2005/003) · doi:10.1044/1092-4388(2005/003
- Perlman A L, 1999, J. Appl. Physiol., 86, 1663, 10.1152/jappl.1999.86.5.1663 · DOI
- 10.1016/0141-5425(91)90018-3 · DOI · Paper page
- 10.1016/S1350-4533(00)00047-3 · DOI · Paper page
- Reddy N, 1994, J. Rehabil. Res. Dev., 31, 335
- Sejdić E, 2010, Physiol. Meas., 31, N1, 10.1088/0967-3334/31/1/N01 · DOI · Paper page
- 10.1007/s00455-005-0013-1 · DOI
- 10.1007/BF00261276 · DOI · Paper page
Cited by
Khalifa, Y., Coyle, J. L., & Sejdić, E. (2020) · Scientific Reports · doi:10.1038/s41598-020-65492-1 · Cited by 82
“The origin of swallowing vibrations picked through accelerometers has been investigated and correlated to hyolaryngeal excursion 14,29 which paved the way for more studies that used swallowing accelerometry to evaluate airway protection 10,17,30,31 .”
BackgroundKhalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2021) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2020.3000057 · Cited by 49
Neck sensor-supported hyoid bone movement tracking during swallowing
Mao, S., Zhang, Z., Khalifa, Y., Donohue, C., Coyle, J. L., & Sejdic, E. (2019) · Royal Society Open Science · doi:10.1098/rsos.181982 · Cited by 47
Quantitative classification of pediatric swallowing through accelerometry
Celeste, M., Azadeh, K., Sejdić, E., Berall, G., & Chau, T. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-34 · Cited by 37
Self-citationKurosu, A., Coyle, J. L., Dudik, J. M., & Sejdic, E. (2019) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.05.038 · Cited by 33
Metadata
- Authors
- Zoratto, D. C. B., Chau, T., & Steele, C. M.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-05-18
- Volume
- 31
- Issue
- 6
- Pages
- 843-855
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2049019911
- Cited by
- 54
- References
- 5
- FWCI
- 10.70
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hyolaryngeal excursion as the physiological source of swallowing accelerometry signals. https://app.cochat.ai/papers/10.1088/0967-3334/31/6/008
- The paper
- Zoratto, D. C. B., Chau, T., & Steele, C. M. (2010). Hyolaryngeal excursion as the physiological source of swallowing accelerometry signals. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/6/008
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.