CoChat

A procedure for denoising dual-axis swallowing accelerometry signals

Sejdić, Ervin, Steele, Catriona M, Chau, Tom · 2010 · Physiological Measurement
Cited by 40

The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.

Abstract

Dual-axis swallowing accelerometry is an emerging tool for the assessment of dysphagia (swallowing difficulties). These signals however can be very noisy as a result of physiological and motion artifacts. In this note, we propose a novel scheme for denoising those signals, i.e. a computationally efficient search for the optimal denoising threshold within a reduced wavelet subspace. To determine a viable subspace, the algorithm relies on the minimum value of the estimated upper bound for the reconstruction error. A numerical analysis of the proposed scheme using synthetic test signals demonstrated that the proposed scheme is computationally more efficient than minimum noiseless description length (MNDL)-based denoising. It also yields smaller reconstruction errors than MNDL, SURE and Donoho denoising methods. When applied to dual-axis swallowing accelerometry signals, the proposed scheme exhibits improved performance for dry, wet and wet chin tuck swallows. These results are important for the further development of medical devices based on dual-axis swallowing accelerometry signals.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/31/1/n01

Cites

2 of 2 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 2 references

Research works printed but not linked: 15

  1. 10.1109/10.568910 · doi:10.1109/10.568910
  2. 10.1109/TSP.2005.855075 · DOI
  3. 10.1109/83.862633 · DOI · Paper page
  4. 10.1109/TNSRE.2004.841384 · DOI · Paper page
  5. 10.1016/S0169-2607(00)00099-7 · DOI
  6. 10.1109/18.382009 · DOI · Paper page
  7. 10.1093/biomet/81.3.425 · DOI · Paper page
  8. Jansen M, 2001, Noise Reduction by Wavelet Thresholding, 10.1007/978-1-4613-0145-5 · DOI · Paper page
  9. 10.1186/1743-0003-3-17 · DOI
  10. Lee J, 2008, Physiol. Meas., 29, 1105, 10.1088/0967-3334/29/9/008 · DOI
  11. Ljung L, 1999, System Identification: Theory for the User
  12. Mallat S G, 1999, A Wavelet Tour of Signal Processing
  13. 10.1109/83.791966 · DOI · Paper page
  14. 10.1016/S1350-4533(00)00047-3 · DOI
  15. 10.1109/LSP.2002.806054 · DOI · Paper page

Cited by

See all 40

Metadata

Authors
Sejdić, E., Steele, C. M., & Chau, T.
Venue
Physiological Measurement
Published
2009-11-26
Volume
31
Issue
1
Pages
N1-N9
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W4250746658
Cited by
40
References
2
FWCI
3.66
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A procedure for denoising dual-axis swallowing accelerometry signals. https://app.cochat.ai/papers/10.1088/0967-3334/31/1/n01
The paper
Sejdić, E., Steele, C. M., & Chau, T. (2010). A procedure for denoising dual-axis swallowing accelerometry signals. Physiological Measurement. https://doi.org/10.1088/0967-3334/31/1/n01

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.