Dynamic profiles of volatile organic compounds in exhaled breath as determined by a coupled PTR-MS/GC-MS study
The DOI matches its Crossref record; 55 of the 55 references it cites were found in a registry or an index.
Abstract
In this phenomenological study we focus on dynamic measurements of volatile organic compounds (VOCs) in exhaled breath under exercise conditions. An experimental setup efficiently combining breath-by-breath analyses using proton transfer reaction mass spectrometry (PTR-MS) with data reflecting the behaviour of major hemodynamic and respiratory parameters is presented. Furthermore, a methodology for complementing continuous VOC profiles obtained by PTR-MS with simultaneous SPME/GC-MS measurements is outlined. These investigations aim at evaluating the impact of breathing patterns, cardiac output or blood pressure on the observed breath concentration and allow for the detection and identification of several VOCs revealing characteristic rest-to-work transitions in response to variations in ventilation or perfusion. Examples of such compounds include isoprene, methyl acetate, butane, DMS and 2-pentanone. In particular, both isoprene and methyl acetate exhibit a drastic rise in concentration shortly after the onset of exercise, usually by a factor of about 3-5 within approximately 1 min of pedalling. These specific VOCs might also be interpreted as potentially sensitive indicators for fluctuations of blood or respiratory flow and can therefore be viewed as candidate compounds for future assessments of hemodynamics, pulmonary function and gas exchange patterns via observed VOC behaviour.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Individual Comparisons by Ranking Methods
Wilcoxon, F. (1945) · Biometrics Bulletin · doi:10.2307/3001968 · Cited by 15,354
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
Respiratory physiology: The essentials
(1975) · British Journal of Diseases of the Chest · doi:10.1016/0007-0971(75)90100-x · Cited by 1,120
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096 · cited 6×
“Exhaled breath contains a number of blood-borne volatile organic compounds (VOCs) with great potential for medical diagnosis and therapeutic monitoring (Miekisch et al., 2004; Amann et al., 2004; Amann and Smith, 2005; Bajtarevic et al., 2009).”
BackgroundInfluentialMeasurement of continuous distributions of ventilation-perfusion ratios: theory
Wagner, P. D., Saltzman, H. A., & West, J. B. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.36.5.588 · Cited by 830 · cited 1×
“…a secondary aim was also to supplement and support continuing efforts to base multiple inert gas elimination technique (MIGET) (Wagner 2008, Wagner et al 1974)) on endogenous VOCs rather than exogenously administered gases, thereby circumventing invasive infusion and improving patient…”
Background(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.160.6.ats8-99 · Cited by 771
Lindinger, W., & Jordan, A. (1998) · Chemical Society Reviews · doi:10.1039/a827347z · Cited by 751
Nitrate, bacteria and human health
Lundberg, J. O., Weitzberg, E., Cole, J. A., & Benjamin, N. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro929 · Cited by 739 · cited 1×
“The concentration in the nasal cavity and the paranasal sinuses is usually much higher than in the lungs, and actually increases in concentration within a few seconds during humming (Lundberg et al 2004, Maniscalco et al 2004).”
BackgroundKharitonov, S., Alving, K., & Barnes, P. (1997) · European Respiratory Journal · doi:10.1183/09031936.97.10071683 · Cited by 664 · cited 1×
“A paradigmatic example within this framework is the small inorganic molecule nitric oxide (NO) (Kharitonov et al 1997, Dweik et al 1998, Bush 2000, Gustafsson 2005, Horvath et al 2003).”
Background
Cited by
A review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationVolatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Self-citationAmann, A., Costello, B. D. L., Miekisch, W., Schubert, J., Buszewski, B., Pleil, J., Ratcliffe, N., & Risby, T. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/3/034001 · Cited by 804
Self-citationAssessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Self-citationSensors for Breath Testing: From Nanomaterials to Comprehensive Disease Detection
Konvalina, G., & Haick, H. (2014) · Accounts of Chemical Research · doi:10.1021/ar400070m · Cited by 561
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Exhaled breath analysis: a review of ‘breath-taking’ methods for off-line analysis
Lawal, O., Ahmed, W. M., Nijsen, T. M. E., Goodacre, R., & Fowler, S. J. (2017) · Metabolomics · doi:10.1007/s11306-017-1241-8 · Cited by 288
Drabińska, N., Flynn, C., Ratcliffe, N., Belluomo, I., Myridakis, A., Gould, O., Fois, M., Smart, A., Devine, T., & Costello, B. D. L. (2021) · Journal of Breath Research · doi:10.1088/1752-7163/abf1d0 · Cited by 288
Sensing Technologies for Detection of Acetone in Human Breath for Diabetes Diagnosis and Monitoring
Saasa, V., Malwela, T., Beukes, M., Mokgotho, M., Liu, C.-P., & Mwakikunga, B. (2018) · Diagnostics · doi:10.3390/diagnostics8010012 · Cited by 287
Filipiak, W., Ruzsanyi, V, Mochalski, P., Filipiak, A., Bajtarevic, A., Ager, C., Denz, H., Hilbe, W., Jamnig, H., Hackl, M., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036008 · Cited by 218
Self-citationAnalysis of Exhaled Breath for Disease Detection
Amann, A., Miekisch, W., Schubert, J., Buszewski, B., Ligor, T., Jezierski, T., Pleil, J., & Risby, T. (2014) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071213-020043 · Cited by 214
Self-citationNanoscale Sensor Technologies for Disease Detection via Volatolomics
Vishinkin, R., & Haick, H. (2015) · Small · doi:10.1002/smll.201501904 · Cited by 199
Physiological modeling of isoprene dynamics in exhaled breath
King, J., Koc, H., Unterkofler, K., Mochalski, P., Kupferthaler, A., Teschl, G., Teschl, S., Hinterhuber, H., & Amann, A. (2010) · Journal of Theoretical Biology · doi:10.1016/j.jtbi.2010.09.028 · Cited by 191
“Furthermore, it can relatively easily be quantified using a variety of methodologically distinct analytical techniques (Kushch et al., 2008; Ligor et al., 2008; Miekisch and Schubert, 2006; Turner et al., 2006; King et al., 2010a).”
BackgroundMethodInfluentialSelf-citationBlood and breath levels of selected volatile organic compounds in healthy volunteers
Mochalski, P., King, J., Klieber, M., Unterkofler, K., Hinterhuber, H., Baumann, M., & Amann, A. (2013) · The Analyst · doi:10.1039/c3an36756h · Cited by 190
Self-citationPTR-MS and GC-MS as complementary techniques for analysis of volatiles: A tutorial review
Majchrzak, T., Wojnowski, W., Lubinska-Szczygeł, M., Różańska, A., Namieśnik, J., & Dymerski, T. (2018) · Analytica Chimica Acta · doi:10.1016/j.aca.2018.06.056 · Cited by 181
Digging deeper into volatile organic compounds associated with cancer
Janfaza, S., Khorsand, B., Nikkhah, M., & Zahiri, J. (2019) · Biology Methods and Protocols · doi:10.1093/biomethods/bpz014 · Cited by 176
Mass spectrometry for real-time quantitative breath analysis
Smith, D., Španěl, P., Herbig, J., & Beauchamp, J. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027101 · Cited by 174
Filipiak, W., Filipiak, A., Sponring, A., Schmid, T., Zelger, B., Ager, C., Klodzinska, E., Denz, H., Pizzini, A., Lucciarini, P., et al. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/2/027111 · Cited by 173
Self-citationNoninvasive detection of lung cancer using exhaled breath
Fu, X., Li, M., Knipp, R. J., Nantz, M. H., & Bousamra, M. (2014) · Cancer Medicine · doi:10.1002/cam4.162 · Cited by 166
Lung cancer biomarkers in exhaled breath
Amann, A., Corradi, M., Mazzone, P., & Mutti, A. (2011) · Expert Review of Molecular Diagnostics · doi:10.1586/erm.10.112 · Cited by 163
Self-citationTaking your breath away: metabolomics breathes life in to personalized medicine
Rattray, N. J. W., Hamrang, Z., Trivedi, D. K., Goodacre, R., & Fowler, S. J. (2014) · Trends in Biotechnology · doi:10.1016/j.tibtech.2014.08.003 · Cited by 160
Metadata
- Authors
- King, J., Mochalski, P., Kupferthaler, A., Unterkofler, K., Koc, H., Filipiak, W., Teschl, S., Hinterhuber, H., & Amann, A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2010-07-28
- Volume
- 31
- Issue
- 9
- Pages
- 1169-1184
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2030255922
- Cited by
- 189
- References
- 55
- FWCI
- 9.10
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.