Heart rate variability analysis using a ballistocardiogram during Valsalva manoeuvre and post exercise
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
We introduced a novel non-constrained technique for estimating heart rate variability (HRV) using a ballistocardiogram (BCG). To assess whether the BCG signal can be used to analyse the cardiac autonomic modulation, HRV parameters derived from the BCG signal (ballistocardiographic HRV, B-HRV) were statistically compared with the HRV parameters from the ECG signal during rest and under two different experimental conditions that induce cardiac autonomic rhythm changes: the Valsalva manoeuvre and static exercise. Time domain, frequency domain and nonlinear analyses were individually performed on 15 healthy subjects to assess whether the BCG can be used to analyse the cardiac autonomic modulation under each condition. For all subjects, the proposed method had averages of relative errors of 5.01 ± 4.72, 5.64 ± 4.83 and 5.98 ± 5.80% for resting, Valsalva and post-exercise sessions, respectively, and the correlation coefficients between the reference (ECG) and proposed (BCG) methods are 0.97, 0.98 and 0.98, for resting, Valsalva and post-exercise sessions, respectively. During cardiac autonomic changes, the B-HRV parameters changed in a pattern that is very similar to the variations in the HRV parameters based on Student's t-test results. In addition, some of the B-HRV parameters changed according to cardiac autonomic rhythms controlled by sympathetic and parasympathetic activities during the experiments. These findings indicate that BCG can provide an accurate and reliable means to evaluate autonomic system activation by HRV in its unconstrained way.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiological time-series analysis using approximate entropy and sample entropy
Richman, J. S., & Moorman, J. R. (2000) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2000.278.6.h2039 · Cited by 7,880
A Real-Time QRS Detection Algorithm
Pan, J., & Tompkins, W. J. (1985) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1985.325532 · Cited by 7,855
Approximate entropy as a measure of system complexity.
Pincus, S. M. (1991) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.88.6.2297 · Cited by 5,811
Pagani, M., Lombardi, F., Guzzetti, S., Rimoldi, O., Furlan, R., Pizzinelli, P., Sandrone, G., Malfatto, G., Dell'Orto, S., & Piccaluga, E. (1986) · Circulation Research · doi:10.1161/01.res.59.2.178 · Cited by 4,130
Kleiger, R. E., Miller, J. P., Bigger, J. T., & Moss, A. J. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90795-8 · Cited by 3,995
Thayer, J. F., Yamamoto, S. S., & Brosschot, J. F. (2010) · International Journal of Cardiology · doi:10.1016/j.ijcard.2009.09.543 · Cited by 2,276
Impact of Reduced Heart Rate Variability on Risk for Cardiac Events: The Framingham Heart Study
Tsuji, H., Larson, M. G., Venditti, F. J., Manders, E. S., Evans, J. C., Feldman, C. L., & Levy, D. (1996) · Circulation · doi:10.1161/01.cir.94.11.2850 · Cited by 1,762
Reduced heart rate variability and mortality risk in an elderly cohort. The Framingham Heart Study
Tsuji, H., Venditti, F. J., Manders, E. S., Evans, J. C., Larson, M. G., Feldman, C. L., & Levy, D. (1994) · Circulation · doi:10.1161/01.cir.90.2.878 · Cited by 1,114
Wearable sensors/systems and their impact on biomedical engineering
Bonato, P. (2003) · IEEE Engineering in Medicine and Biology Magazine · doi:10.1109/memb.2003.1213622 · Cited by 382
The reliability of short-term measurements of heart rate variability
Sandercock, G. R. H., Bromley, P. D., & Brodie, D. A. (2005) · International Journal of Cardiology · doi:10.1016/j.ijcard.2004.09.013 · Cited by 307
Autonomic space and psychophysiological response
BERNTSON, G. G., CACIOPPO, J. T., QUIGLEY, K. S., & FABRO, V. T. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb01024.x · Cited by 289
Chee, Y., Han, J., Youn, J., & Park, K. (2005) · Physiological Measurement · doi:10.1088/0967-3334/26/4/007 · Cited by 111
Self-citationA new approach for non-intrusive monitoring of blood pressure on a toilet seat
Kim, J. S., Chee, Y. J., Park, J. W., Choi, J. W., & Park, K. S. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/2/010 · Cited by 64
Self-citation
Cited by
Ballistocardiography and Seismocardiography: A Review of Recent Advances
Inan, O. T., Migeotte, P.-F., Park, K.-S., Etemadi, M., Tavakolian, K., Casanella, R., Zanetti, J., Tank, J., Funtova, I., Prisk, G. K., et al. (2015) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2014.2361732 · Cited by 775
“Performance of HRV analysis using BCG measured on weighing scale-type load cell is evaluated in reference to the ECG during the resting and under each condition of Valsalva and postexercise sessions that induce cardiac autonomic rhythm changes [72].”
MethodSelf-citationNon-invasive human vital signs monitoring based on twin-core optical fiber sensors
Tan, F., Chen, S., Lyu, W., Liu, Z., Yu, C., Lu, C., & Tam, H.-Y. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.005940 · Cited by 62
Heart rate variability in patients with major depression disorder during a clinical autonomic test
Chen, X., Yang, R., Kuang, D., Zhang, L., Lv, R., Huang, X., Wu, F., Lao, G., & Ou, S. (2017) · Psychiatry Research · doi:10.1016/j.psychres.2017.06.041 · Cited by 44
Metadata
- Authors
- Shin, J. H., Hwang, S. H., Chang, M. H., & Park, K. S.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2011-07-08
- Volume
- 32
- Issue
- 8
- Pages
- 1239-1264
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W1971024694
- Cited by
- 55
- References
- 13
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.