Cited by 53Physical Activity and HealthOccupational Health and PerformanceContext-Aware Activity Recognition Systems

Wrist-worn accelerometers in assessment of energy expenditure during intensive training

Open access
Kinnunen, H, Tanskanen, M, Kyröläinen, H, Westerterp, K R·2012·Physiological Measurement

Abstract

We assessed the ability of the Polar activity recorder (AR) to measure energy expenditure (EE) during military training. Twenty-four voluntary male conscripts participated in the study and wore an AR on the non-dominant wrist 24 h a day for 7 d. The AR analyzed and stored the frequency of hand movements (f_hand) into memory at 1 min intervals. The relationship between f_hand and EE was studied over a 7 d period of military training using the doubly labeled water (DLW) technique. In addition, the relationship between f_hand and EE was analyzed during walking and running on a treadmill with an indirect calorimeter (IC), and f_hand was measured during a supervised 45 min field march test where the conscripts carried combat gear. EE was expressed as physical activity level (PAL), total energy expenditure (TEE), and activity-induced energy expenditure adjusted for body mass (AEE/BM). Over the 7 d period, f_hand alone explained 46% of inter-individual variation in PAL(DLW). After inclusion of body height and mass in the model used to predict PAL(DLW) from f_hand, a very high positive correlation and a low standard error of estimate (SEE) were observed between the AR and DLW techniques: for TEE r = 0.86 (p < 0.001), the SEE was 6.3%, and for AEE/BM r = 0.84 (p < 0.001), the SEE was 12.8%. In the treadmill exercise, f_hand correlated highly with PAL(IC) (r = 0.97 ± 0.02). In the 45 min field march test, the AR measured similar f_hand as on the treadmill at the same speed. In conclusion, the wrist-worn AR can be regarded as a reliable and valid method for assessing EE during intensive training.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/33/11/1841

Cites

39 of 39 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • The Polar Active has shown to correlate (r2=0.74) with the doubly labeled water technique for assessing energy expenditure during military training.

    “The Polar Active has shown to correlate (r2=0.74) with the doubly labeled water technique for assessing energy expenditure during military training, which related to the study setting [82].”

    From Consumer-based wearable activity trackers increase physical activity participation: systematic review and meta-analysis (2019) · cites this paper as [82]

    Table 2 reports a correlation of r = 0.86 between wrist-device and doubly labeled water estimates of total energy expenditure during seven days of military training; squaring it gives r² ≈ 0.74. However, section 2.3 identifies the device as a Polar AR prototype of the Polar FA20, not the Polar Active named in the claim. (LLM, conf=0.87)

    Experimental — accuracy not yet measured

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Kinnunen, H., Tanskanen, M., Kyröläinen, H., & Westerterp, K. R.
Affiliations
  • Polar (Finland) (FI)
  • University of Jyväskylä (FI)
  • Maastricht University (NL)
Corresponding author
Kinnunen, H
Venue
Physiological Measurement
Published
2012-10-31
Volume
33
Issue
11
Pages
1841-1854
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2011216090
Cited by
53
References
39
Citations by year
2026: 2 · 2025: 1 · 2024: 3 · 2023: 2 · 2022: 6 · 2021: 4 · 2020: 6 · 2019: 11 · 2018: 2 · 2017: 5 · 2016: 2 · 2015: 2 · 2014: 2 · 2013: 5
FWCI
1.93
Type
journal article
Language
en
Open access
Locations
  • Physiological Measurement (publishedVersion)
  • PubMed (publishedVersion)
  • Research Publications (Maastricht University) (publishedVersion, other-oa)
  • Research Publications (Maastricht University) (submittedVersion, other-oa)
Funders
Suomen Kulttuurirahasto
Topics
  • Health Sciences › Medicine › Physiology › Physical Activity and Health
  • Health Sciences › Health Professions › Occupational Therapy › Occupational Health and Performance
  • Physical Sciences › Computer Science › Computer Vision and Pattern Recognition › Context-Aware Activity Recognition Systems
Keywords
wrist-worn accelerometers, energy expenditure, military education, physical activity level, doubly labeled water, treadmill walking and running
MeSH terms
Energy Metabolism, Exercise Test, Humans, Male, Military Personnel, Running, Wrist, Reproducibility of Results, Exercise, Linear Models, Walking, Young Adult, Accelerometry

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review