Signal quality indices and data fusion for determining clinical acceptability of electrocardiograms
Open accessThe DOI matches its Crossref record; 27 of the 28 references it cites were found in a registry or an index.
Abstract
A completely automated algorithm to detect poor-quality electrocardiograms (ECGs) is described. The algorithm is based on both novel and previously published signal quality metrics, originally designed for intensive care monitoring. The algorithms have been adapted for use on short (5-10 s) single- and multi-lead ECGs. The metrics quantify spectral energy distribution, higher order moments and inter-channel and inter-algorithm agreement. Seven metrics were calculated for each channel (84 features in all) and presented to either a multi-layer perceptron artificial neural network or a support vector machine (SVM) for training on a multiple-annotator labelled and adjudicated training dataset. A single-lead version of the algorithm was also developed in a similar manner. Data were drawn from the PhysioNet Challenge 2011 dataset where binary labels were available, on 1500 12-lead ECGs indicating whether the entire recording was acceptable or unacceptable for clinical interpretation. We re-annotated all the leads in both the training set (1000 labelled ECGs) and test dataset (500 12-lead ECGs where labels were not publicly available) using two independent annotators, and a third for adjudication of differences. We found that low-quality data accounted for only 16% of the ECG leads. To balance the classes (between high and low quality), we created extra noisy data samples by adding noise from PhysioNet's noise stress test database to some of the clean 12-lead ECGs. No data were shared between training and test sets. A classification accuracy of 98% on the training data and 97% on the test data were achieved. Upon inspection, incorrectly classified data were found to be borderline cases which could be classified either way. If these cases were more consistently labelled, we expect our approach to achieve an accuracy closer to 100%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ambulatory data measured with wearable sensors, mobile phones, and surveys tend to be noisy.”
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
LIBSVM: A library for support vector machines
Chang, C.-C., & Lin, C.-J. (2011) · ACM Transactions on Intelligent Systems and Technology · doi:10.1145/1961189.1961199 · Cited by 40,918
Book Review: Pattern Recognition and Machine Learning
Nasrabadi, N. M. (2007) · Journal of Electronic Imaging · doi:10.1117/1.2819119 · Cited by 22,066
Goldberger, A. L., Amaral, L. A. N., Glass, L., Hausdorff, J. M., Ivanov, P. C., Mark, R. G., Mietus, J. E., Moody, G. B., Peng, C.-K., & Stanley, H. E. (2000) · Circulation · doi:10.1161/01.cir.101.23.e215 · Cited by 14,809
Pattern Recognition and Machine Learning
(2006) · doi:10.1007/978-0-387-45528-0 · Cited by 9,824
The Levenberg-Marquardt algorithm: Implementation and theory
Moré, J. J. (1978) · Lecture Notes in Mathematics · doi:10.1007/bfb0067700 · Cited by 5,773
A Practical Guide to Support Vector Classication
Hsu, C., Chang, C.-C., & Lin, C. (2008) · Cited by 5,083
Pattern Recognition and Machine Learning
Neal, R. M. (2007) · Technometrics · doi:10.1198/tech.2007.s518 · Cited by 4,571
A User’s Guide to Support Vector Machines
Ben-Hur, A., & Weston, J. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60327-241-4_13 · Cited by 822
Advanced Methods And Tools for ECG Data Analysis
Clifford, G. D., Azuaje, F. J., & McSharry, P. (2006) · Cited by 808
Self-citationLi, Q., Mark, R. G., & Clifford, G. D. (2008) · Physiological Measurement · doi:10.1088/0967-3334/29/1/002 · Cited by 426
Self-citation
Cited by
Items 201–300 of 352
de Moraes, J. L., Paixao, G. M., Gomes, P. R., Mendes, E. M. A. M., Ribeiro, A. L. P., & Beda, A. (2023) · Physiological Measurement · doi:10.1088/1361-6579/acbc09 · Cited by 5
Automated detection of non-physiological artifacts on ECG signal: UK Biobank and CRIC
Bukhari, S. H. A., Kewalramani, S., Witzigreuter, L., Pourbemany, J., Barbato, N. A., Daw, J., Dhar, R., Rincon-Choles, H., Rao, P. S., Bhat, Z. Y., et al. (2025) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2025.110787 · Cited by 5
The impact of skin preparation method on electrocardiogram quality in horses.
McCrae, P., Spong, H., Mahnam, A., Bashura, Y., & Pearson, W. (2024) · PubMed Central · Cited by 5
Yuan, S., He, Z., Zhao, J., Yang, Z., & Yuan, Z. (2023) · Applied Intelligence · doi:10.1007/s10489-023-04549-w · Cited by 5
Wang, X., Chang, C., Cao, D., Han, K., Sun, F., Huang, Y., Wang, M., Xu, C., Luo, X., Yan, R., et al. (2026) · TechRxiv · doi:10.36227/techrxiv.177092226.67693184/v1 · Cited by 5
The Social Implications of Digital Health Technology
Lievevrouw, E., & Hoyweghen, I. V. (2019) · Lirias · Cited by 5
Xiao, Z., Vos, M. D., Chatzichristos, C., Jiang, Y., Zhao, M., Ding, F., Yang, C., Li, J., & Liu, C. (2025) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2025.3601807 · Cited by 5
Extraction and Detection of Fetal Electrocardiograms from Abdominal Recordings
Andreotti Lage, F. (2016) · Qucosa (Saxon State and University Library Dresden) · Cited by 5
A signal quality analysis method for electrocardiosignals in the CS domain
Liu, J., Xu, W., Zhao, P., & Hua, J. (2021) · Measurement Science and Technology · doi:10.1088/1361-6501/abf176 · Cited by 5
Evaluation of a Continuous ECG Quality Indicator Based on the Autocorrelation Function
Moeyersons, J., Testelmans, D., Buyse, B., Willems, R., Huffel, S. V., & Varon, C. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.210 · Cited by 5
Identification of a signal for an optimal heart beat detection in multimodal physiological datasets
Schulte, R., Krug, J., & Rose, G. (2014) · Computing in cardiology · Cited by 5
RF-Free infant ECG monitoring: Performance and signal quality assessment
Chehbani, A., Sahuguede, S., & Julien‐Vergonjanne, A. (2022) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc48229.2022.9871387 · Cited by 4
Yamane, N., Mishra, V., & Goodwin, M. S. (2024) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-031-59717-6_8 · Cited by 4
Inter-patient electrocardiogram quality assessment using cascaded domain adaptation
Li, H., Han, J., Zhang, X., Liu, Y., Xing, K., & Yang, H. (2025) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2025.109033 · Cited by 4
A novel method based on shifted rank-1 reconstruction for removing EMG artifacts in ECG signals
Chen, X., Zheng, S., Peng, L., Zhong, Q., & Liu, H. (2023) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2023.104967 · Cited by 4
A Human-in-the-Loop Method for Annotation of Events in Biomedical Signals
Seeuws, N., Vos, M. D., & Bertrand, A. (2024) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2024.3460533 · Cited by 4
The New Approach for ECG Signal Quality Index Estimation on the Base of Robust Statistic
Pander, T., & Przybyła, T. (2019) · Advances in intelligent systems and computing · doi:10.1007/978-3-030-23762-2_43 · Cited by 4
Venkat, S. J., Chang, H. W., Kim, H. J., Cho, Y. H., Lee, J. Y., & Koo, K. (2023) · Biomimetics · doi:10.3390/biomimetics8010119 · Cited by 4
Decision Tree-based Model for Signal Quality Scanning in Wearable ECG
Ma, C., Wang, Z., Yang, M., Li, J., & Liu", C. (2022) · Computing in cardiology · doi:10.22489/cinc.2022.121 · Cited by 4
Modeling fetal cardiac valve intervals and fetal-maternal interactions
Marzbanrad, F. (2015) · Minerva Access (University of Melbourne) · Cited by 4
Diffusion-Based Electrocardiography Noise Quantification via Anomaly DetectionPreprint
Han, T.-S., Heo, J.-W., Kim, H., Lee, C.-H., Huh, H., Choi, E., Kim, H. J., & Kim, D. (2025) · arXiv · doi:10.48550/arxiv.2506.11815 · Cited by 4
Design and evaluation of textile electrodes for biological signal monitoring
Le, K. (2023) · cIRcle (University of British Columbia) · doi:10.14288/1.0431088 · Cited by 4
Signal Quality Assessment of F-waves in Atrial Fibrillation
Henriksson, M., Petrėnas, A., Marozas, V., Sandberg, F., & Sörnmo, L. (2017) · Computing in cardiology · doi:10.22489/cinc.2017.051-153 · Cited by 4
EcgScorer: An open source MATLAB toolbox for ECG signal quality assessment
Alexendre, N., Kuetche, F., Pascal, N. E., & Thierry, S. (2024) · SoftwareX · doi:10.1016/j.softx.2024.101900 · Cited by 4
Brunyé, T. T., Petrimoulx, M. V., & Cantelon, J. A. (2026) · Sensors · doi:10.3390/s26072034 · Cited by 3
Elgendi, M., van der Bijl, K., & Menon, C. (2023) · Diagnostics · doi:10.3390/diagnostics13223479 · Cited by 3
A quality index for construction big data in shield tunneling
Zhang, C., Ren, Y., Huang, Q., & Chen, R.-P. (2025) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2025.111023 · Cited by 3
Representative Databases for Feature Engineering and Computational Intelligence in ECG Processing
Gao, H., Liu, C., Shen, Q., & Li, J. (2020) · Springer eBooks · doi:10.1007/978-981-15-3824-7_2 · Cited by 3
Instant Automated Inference of Perceived Mental Stress through Smartphone PPG and Thermal ImagingPreprint
Cho, Y., Julier, S., & Bianchi‐Berthouze, N. (2018) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/326157 · Cited by 3
Shahrbabak, S. M., Bouzid, Z., Inan, O. T., & Hahn, J. (2025) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ae0c4b · Cited by 3
Grid mapping: a novel method of signal quality evaluation on a single lead electrocardiogram
Li, Y., & Tang, X. (2017) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-017-0594-7 · Cited by 3
Electrocardiogram Quality Assessment with Autoencoder
Garus, J., Pabian, M., Wiśniewski, M., & Śnieżyński, B. (2021) · Lecture notes in computer science · doi:10.1007/978-3-030-77967-2_58 · Cited by 3
Inference-based subject atypicality and signal quality indicators for physiological data
Tivay, A., Kramer, G. C., & Hahn, J. (2021) · doi:10.1145/3446913.3460316 · Cited by 3
Bachi, L., Varanini, M., Costi, M., Lombardi, D., & Billeci, L. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.109288 · Cited by 3
Localization of Noise Sources in a Multilead Electrophysiological Record
Augustyniak, P. (2017) · Advances in intelligent systems and computing · doi:10.1007/978-3-319-66905-2_5 · Cited by 3
A kNN Approach for ECG Signal Quality Classification
Tanantong, T. (2016) · International Journal of Information and Electronics Engineering · Cited by 3
Duranteau, O., & Popoff, B. (2026) · Current Opinion in Anaesthesiology · doi:10.1097/aco.0000000000001625 · Cited by 2
A Geometric Approach to Biomedical Time Series Analysis
Malik, J. (2020) · Cited by 2
Deep Learning Signal Quality Assessment for Continuous Wearable ECG Monitoring
Ribeiro, E., Soares, Q. B., de Almeida, D. D. A., Verardino, R. G. S., Reis, T. C., Júnior, D. N. V., Pereira, J., Samesima, N., Rabello, G. D. C. M., Monteiro, R., et al. (2025) · Computing in cardiology · doi:10.22489/cinc.2025.382 · Cited by 2
False alarm reduction in continuous cardiac monitoring using 3D acceleration signals
Tanantong, T., Nantajeewarawat, E., & Thiemjarus, S. (2014) · International Computer Science and Engineering Conference · doi:10.1109/icsec.2014.6978218 · Cited by 2
Accurate RR-interval extraction from single-lead, telehealth electrocardiogram signalsPreprint
Ho, S. Y. S., Ding, Z., Wong, D., Kristof, F., Brimicombe, J. D., Cowie, M., Dymond, A., Lindén, H. C., Lip, G. Y. H., Williams, K. M., et al. (2025) · medRxiv · doi:10.1101/2025.03.10.25323655 · Cited by 2
Global-key region collaborative noise-aware for electrocardiogram signal quality assessment
Fan, J., Chang, H., Han, H., & Luo, J. (2026) · PLoS ONE · doi:10.1371/journal.pone.0355335 · Cited by 2
Temporal phenotyping of paroxysmal atrial fibrillation reveals prognostic circadian subtypes
Biton, S. B., Sobel, J., Benaim, A. R., Zvuloni, E., Almog, R., Oster, J., Laufer, I., Green, I., Suleiman, M. A., Tsutsui, K., et al. (2026) · Machine Learning Health · doi:10.1088/3049-477x/ae375f · Cited by 2
Self-citationHigh-Reliability Signal Quality Validation for Biosignals Using Sensor Fusion and Software Indices
Adams, B. (2026) · Sensors · doi:10.3390/s26113478 · Cited by 2
Nardelli, M., Lanatà, A., Valenza, G., Sgorbini, M., Baragli, P., & Scilingo, E. P. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512373 · Cited by 2
Hu, Y., Liu, Q., Zhou, Z., Xu, W., & Tang, H. X. (2025) · Sensors · doi:10.3390/s25237152 · Cited by 2
Methods for improving data acquisition and signal processing for monitoring the ECG
Dore, H. (2023) · Sussex Research Online (University of Sussex) · Cited by 2
Yuan, S., He, Z., Zhao, J., & Yuan, Z. (2021) · IEEE International Conference on Bioinformatics and Biomedicine (BIBM) · doi:10.1109/bibm52615.2021.9669474 · Cited by 2
Signal Quality Assessment in Wearable ECG Devices
Taji, B. (2019) · uO Research (University of Ottawa) · doi:10.20381/ruor-23103 · Cited by 2
Mercau, R., & Agustín, N. (2014) · RECERCAT (Consorci de Serveis Universitaris de Catalunya) · Cited by 2
Novel Low Complexity Biomedical Signal Processing Techniques for Online Applications
Yazdani, S. (2018) · Infoscience (Ecole Polytechnique Fédérale de Lausanne) · doi:10.5075/epfl-thesis-8522 · Cited by 2
Moon, J., Kim, J.-H., Dzikowicz, D. J., Bailey, B., An, J., & Joo, H. J. (2025) · IEEE Access · doi:10.1109/access.2025.3620804 · Cited by 2
Automatic Detection of Respiratory Effort Related Arousals From Polysomnographic Recordings
Lazić, I., Jakovljevic, N. M., Despotović, D., & Lončar-Turukalo, T. (2018) · Computing in cardiology · doi:10.22489/cinc.2018.226 · Cited by 2
A study on the effects of window size on electrocardiogram signal quality classification
Tanantong, T. (2016) · Universiti Utara Malaysia Institutional Repository (Universiti Utara Malaysia) · Cited by 2
Subset Selection and Feature Identification in the Electrocardiogram
Hendryx, E. P. (2018) · Rice Research Repository (Rice University) · Cited by 2
Analysis of Compressively Sensed Electrocardiogram for Detection of Atrial Fibrillation
Abdelazez, M. (2022) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2022-14931 · Cited by 1
The intersection of driving and health: Toward a framework for healthy driving
Jabeur, N. H., Haddad, H., Bouyahia, Z., Outay, F., & Mastouri, M. (2026) · Journal of Transport & Health · doi:10.1016/j.jth.2026.102260 · Cited by 1
EQA-MDL: Wearable ECG Signal Quality Assessment via Multi-Scale Difference Learning
Fan, H., Luo, J., Chang, H., Han, H., Tan, J., Guo, C., Muwei, L. I., & Wang, Z. (2026) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2026.3667883 · Cited by 1
Zhu, G., Li, Y., Wu, Y., Lie, Z., Chen, C., & Chen, W. (2022) · Lecture notes of the Institute for Computer Sciences, Social Informatics and Telecommunications Engineering · doi:10.1007/978-3-031-06368-8_21 · Cited by 1
PN-QRS: An Uncertainty-aware QRS-complex Detection Method for Wearable ECGsPreprint
Wang, X., Gao, H., Ma, C., Cui, C., Zhu, T., Cheng, X., Li, J., & Liu, C. (2022) · TechRxiv · doi:10.36227/techrxiv.21431673 · Cited by 1
PN-QRS: An Uncertainty-aware QRS-complex Detection Method for Wearable ECGsPreprint
Wang, X., Gao, H., Ma, C., Cui, C., Zhu, T., Cheng, X., Li, J., & Liu, C. (2022) · TechRxiv · doi:10.36227/techrxiv.21431673.v1 · Cited by 1
Tran, K. D. (2026) · medRxiv · doi:10.64898/2026.08.25.26361304 · Cited by 1
Integration of Artifact Detection in Clinical Decision Support Systems
Nizami, S. (2016) · Carleton University's Institutional Repository (MacOdrum Library, Carleton University) · doi:10.22215/etd/2016-11361 · Cited by 1
A New Spectrum Driven Index for the Assessment of ECG Signal Quality
Jarchi, D., Procházka, A., & Sanei, S. (2020) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc44109.2020.9175573 · Cited by 1
A model for predicting emergency physician opinion of electrocardiogram tracing data quality
Goebel, M., Busico, L., Snow, G. L., & Bledsoe, J. R. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.05.001 · Cited by 1
Velez, D., Lourenço, A., Pereira, M., Coutinho, D., & Carreiras, C. (2026) · Journal of Experimental and Theoretical Analyses · doi:10.3390/jeta4020014 · Cited by 1
Feldman, K., Rohan, A., & Chawla, N. V. (2021) · CIN Computers Informatics Nursing · doi:10.1097/cin.0000000000000728 · Cited by 1
Demir, B., Domazet, E., Dupljak, E., & Nesimi, S. (2026) · Mediterranean Conference on Embedded Computing (MECO) · doi:10.1109/meco70748.2026.11579119 · Cited by 1
Chehbani, A. (2024) · theses.fr (ABES) · doi:10.70675/53f2cbf2zbd32z4c4ezbce2z955510e6d13f · Cited by 1
Test-Time Adaptation for ECG Classification via SQI-Gated Self-training and Beat-Rhythm Consistency
Jiang, W., Deng, Z., Zhou, J., Wang, H., Ou, Y., & Zheng, Y. (2026) · Lecture notes in computer science · doi:10.1007/978-3-032-38260-3_55 · Cited by 1
Information-Theoretic Analysis of Cardiorespiratory Interactions During Apneic Events in Sleep
Lazić, I., Lončar-Turukalo, T., & Faes, L. (2020) · Conference of the European Study Group on Cardiovascular Oscillations (ESGCO) · doi:10.1109/esgco49734.2020.9158168 · Cited by 1
Singh, O. P., Bocchino, A., Cherian, D., Hu, Y., Haslinger, M. J., Fechtig, D. J., Prinz, I., Brandstätter, S., Galvin, P., & O’Mahony, C. (2026) · IEEE Access · doi:10.1109/access.2026.3659519 · Cited by 1
Miller, I. C. (2019) · Lirias (KU Leuven) · Cited by 1
Geavanceerde tools voor ambulante ECG en respiratoire analyse
Moeyersons, J. (2021) · Lirias · Cited by 1
Niu, X., Yang, Y., Wang, L., Liu, Y., Wang, X., & Liu, Y. (2025) · Measurement · doi:10.1016/j.measurement.2025.117481 · Cited by 1
Algorithms and systems for home telemonitoring in biomedical \napplications
Dessì, A. (2015) · VEprints - Universita degli Studi di Cagliari · Cited by 1
How to Evaluate Signal Quality of ear-ECG?
Żyliński, M., Rao, Q., Davies, H. J., & Mandic, D. P. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253403 · Cited by 1
A scalogram tensor decomposition based ECG quality assessment
Sharma, A., Sawant, N. K., & Patidar, S. (2023) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2023.09.002 · Cited by 1
Cho, Y. (2019) · UCL Discovery (University College London) · Cited by 1
The Application of Non-invasive Inverse ECG Techniques in Cardiomyopathy
Boonstra, M. (2023) · Utrecht University Repository (Utrecht University) · doi:10.33540/1807
Jahmunah, V. (2022) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/170476
Luo, J., Han, H., Chang, H., Chen, J.-B., Wang, R., Fan, H., Guo, C., & Muwei, L. I. (2026) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2026.111509
Towards Dataset Agnostic ECG Signal Quality Assessments for Psychophysiological Analysis
Dair, Z., Dockray, S., & O’Reilly, R. (2026) · Journal of Psychophysiology · doi:10.1027/0269-8803/a000357
Boström, M., Jonsäll, E., Allenmark, F., Amoignon, O., Persson, E., & Elçadi, G. H. (2026) · Frontiers in Psychology · doi:10.3389/fpsyg.2026.1892662
ECG Quality Assessment Framework by Using Attentional Convolution Neural Network
Jin, Y., Li, Z., Tian, Y., Wang, M., Wei, X., Liu, C., & Yang, X. (2023) · Frontiers in artificial intelligence and applications · doi:10.3233/faia231101
Quality Level Classification of ECG Measured using Non-Constraint Approach
Kim, Y. J., Heo, J., Park, K., & Kim, S. (2016) · Journal of Biomedical Engineering Research · doi:10.9718/jber.2016.37.5.161
Analysis and refinement of pulse rate variability
Li, Y. (2019) · University Libraries (University of Maryland) · doi:10.13016/4dka-vhp2
Bayesian Fusion of Continuous-Valued Labels in Biomedical Applications
Zhu, T. (2016) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.13140/rg.2.2.12486.11841
Prasetya, D. S. B., Busono, P., Supriyanto, E., & Wibawa, W. (2026) · Research Square · doi:10.21203/rs.3.rs-10366743/v1
Opauszky, M., Ivanova, N., Shpak, Y., & Marchenko, N. (2026) · Science Journal of Public Health · doi:10.11648/j.sjph.20261401.16
Test Bench for Measuring the Effects of Contact Pressure in cECG Measurements*
Prüßmann, J., Leonhardt, S. K., & Lueken, M. (2024) · IFAC-PapersOnLine · doi:10.1016/j.ifacol.2024.11.020
Smallwood, C. D. (2018) · Digital Repository Service (Northeastern University) · doi:10.17760/d20316411
Wu, D., Zheng, J., Wu, H., Wang, W., Silva, I., & Zhang, Z. (2014) · Springer eBooks
Alizadeh-Meghrazi, M., Ying, B., Schlums, A., Lam, E., Eskandarian, L., Abbas, F., Sidhu, G., Mahnam, A., Moineau, B., & Popović, M. R. (2021) · Figshare · doi:10.6084/m9.figshare.14955819
Chen, X., Xu, X., Zheng, S., & Xu, J. (2026) · Research Square · doi:10.21203/rs.3.rs-10647910/v1
Respiratory quality indices for automated monitoring of respiration from sensor data
Birrenkott, D. A. (2018) · Oxford University Research Archive (ORA) (University of Oxford) · doi:10.5287/ora-b7qx19nvy
Multimodal artificial intelligence for coronary stenosis detection from exercise electrocardiography
Zheng, Y., Feng, N., Pu, H., Huang, Q., Li, D., Kang, P., huang, D., Deng, G., & Liu, Y. (2026) · Engineering Applications of Artificial Intelligence · doi:10.1016/j.engappai.2026.116580
Development of Smart Textile Systems for Electrophysiological Monitoring
Alizadeh-Meghrazi, M. (2022) · TSpace (University of Toronto)
Autocorrelation-based signal quality assessment for ballistocardiogram: a peak-free approach
Ren, H., Li, S., Zhang, D., Qianghua, L., Deng, M., Wu, D., & Su, B. (2026) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/aebbc0
Metadata
- Authors
- Clifford, G. D., Behar, J., Li, Q., & Rezek, I.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2012-08-17
- Volume
- 33
- Issue
- 9
- Pages
- 1419-1433
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2122930900
- Cited by
- 292
- References
- 28
- FWCI
- 7.67
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.